Using Four-Point Impedance to Detect and Locate Blood during Cochlear Implantation

被引:2
|
作者
Razmovski, Tayla [1 ]
Collins, Aaron [1 ]
Bester, Christofer [1 ]
O'Leary, Stephen [1 ,2 ]
机构
[1] Univ Melbourne, Dept Surg Otolaryngol, East Melbourne, Vic 3002, Australia
[2] Royal Victorian Eye & Ear Hosp, East Melbourne, Vic 3002, Australia
来源
2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC | 2023年
关键词
HEARING; HISTOPATHOLOGY;
D O I
10.1109/EMBC40787.2023.10340312
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Biosensing technologies are emerging as an important consideration when designing implantable medical devices. For cochlear implants, biosensors may help preserve the natural hearing a patient has prior to implantation by detecting blood in the cochlea during insertion. If blood enters the cochlea, it creates a hostile environment leading to further hearing loss and reduced device function. Here we present four-point impedance, measured directly from a commercial cochlear implant, as a biosensor for real-time detection of blood in the cochlea. The four-point impedance of different concentrations of whole blood in saline were measured using the impedance-measuring capabilities of a cochlear implant with a square-wave stimulation. Impedance derived from a cochlear implant succeeded in differentiating concentrations of blood in saline with results from a sensitivity analysis showing the lowest concentration the system could detect was between 12 % to 21 % of whole blood. In a subsequent in-vitro study, continuous four-point impedance was measured from a cochlear implant while it was inserted into a 3D printed cochlear model, followed by an injection of blood to emulate surgical events. These results demonstrated four-point impedance from a cochlear implant can instantaneously detect the addition of blood within the cochlea and localize it along the electrode array. The adaptation of a biosensing tool using a cochlear implant provides more information that can be relayed to the surgeon intraoperatively to potentially enhance hearing outcomes with the implant. Clinical Relevance - Using the cochlear implant itself to detect intra-cochlear bleeding may open therapeutic avenues to prevent further hearing loss.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Electrical Impedance to Assess Facial Nerve Proximity During Robotic Cochlear Implantation
    Anso, Juan
    Balmer, Thomas W.
    Jegge, Yves
    Kalvoy, Havard
    Bell, Brett J.
    Dur, Cilgia
    Calvo, Enric M.
    Williamson, Tom M.
    Gerber, Nicolas
    Ferrario, Damien
    Forterre, Frank
    Buchler, Philippe
    Stahel, Andreas
    Caversaccio, Marco D.
    Weber, Stefan
    Gavaghan, Kate A.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (01) : 237 - 245
  • [32] Estimating parameters for psychometric functions using the four-point sampling method
    Lam, CF
    Dubno, JR
    Ahlstrom, JB
    He, NJ
    Mills, JH
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (06): : 3697 - 3703
  • [33] Degradation Assessment in IGBT Modules Using Four-Point Probing Approach
    Pedersen, Kristian Bonderup
    Kristensen, Peter Kjaer
    Popok, Vladimir
    Pedersen, Kjeld
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (05) : 2405 - 2412
  • [34] Generalized four-point characterization method using capacitive and ohmic contacts
    Kim, Brian S.
    Zhou, Wang
    Shah, Yash D.
    Zhou, Chuanle
    Isik, N.
    Grayson, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):
  • [35] Active Guarding of a Four-point Impedance Probe with one Common Guard Electrode for Maximum Readout Bandwidth
    Wolffenbuttel, Reinoud
    de Graaf, Ger
    2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, : 2101 - 2105
  • [36] Vibrational power flow analysis of a cylindrical shell using a four-point technique
    Salimi-Mofrad, H.
    Ziaei-Rad, S.
    Moradi, M.
    International Journal of Acoustics and Vibrations, 2014, 19 (02): : 127 - 130
  • [37] Single grain boundary characterization of Nb-doped SrTiO3 bicrystals using ac four-point impedance spectroscopy
    Hwang, JH
    Johnson, KD
    Mason, TO
    Dravid, VP
    APPLIED PHYSICS LETTERS, 2000, 76 (18) : 2621 - 2623
  • [38] Evaluating four-point bend fatigue of asphalt mix using image analysis
    Hartman, AM
    Gilchrist, MC
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2004, 16 (01) : 60 - 68
  • [39] Characterization of semiconductor surface conductivity by using microscopic four-point probe technique
    Li, J. C.
    Wang, Y.
    Ba, D. C.
    18TH INTERNATIONAL VACUUM CONGRESS (IVC-18), 2012, 32 : 347 - 355
  • [40] Vibrational Power Flow Analysis of a Cylindrical Shell Using a Four-Point Technique
    Salimi-Mofrad, H.
    Ziaei-Rad, S.
    Moradi, M.
    INTERNATIONAL JOURNAL OF ACOUSTICS AND VIBRATION, 2014, 19 (02): : 127 - 130