Using Four-Point Impedance to Detect and Locate Blood during Cochlear Implantation

被引:2
|
作者
Razmovski, Tayla [1 ]
Collins, Aaron [1 ]
Bester, Christofer [1 ]
O'Leary, Stephen [1 ,2 ]
机构
[1] Univ Melbourne, Dept Surg Otolaryngol, East Melbourne, Vic 3002, Australia
[2] Royal Victorian Eye & Ear Hosp, East Melbourne, Vic 3002, Australia
来源
2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC | 2023年
关键词
HEARING; HISTOPATHOLOGY;
D O I
10.1109/EMBC40787.2023.10340312
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Biosensing technologies are emerging as an important consideration when designing implantable medical devices. For cochlear implants, biosensors may help preserve the natural hearing a patient has prior to implantation by detecting blood in the cochlea during insertion. If blood enters the cochlea, it creates a hostile environment leading to further hearing loss and reduced device function. Here we present four-point impedance, measured directly from a commercial cochlear implant, as a biosensor for real-time detection of blood in the cochlea. The four-point impedance of different concentrations of whole blood in saline were measured using the impedance-measuring capabilities of a cochlear implant with a square-wave stimulation. Impedance derived from a cochlear implant succeeded in differentiating concentrations of blood in saline with results from a sensitivity analysis showing the lowest concentration the system could detect was between 12 % to 21 % of whole blood. In a subsequent in-vitro study, continuous four-point impedance was measured from a cochlear implant while it was inserted into a 3D printed cochlear model, followed by an injection of blood to emulate surgical events. These results demonstrated four-point impedance from a cochlear implant can instantaneously detect the addition of blood within the cochlea and localize it along the electrode array. The adaptation of a biosensing tool using a cochlear implant provides more information that can be relayed to the surgeon intraoperatively to potentially enhance hearing outcomes with the implant. Clinical Relevance - Using the cochlear implant itself to detect intra-cochlear bleeding may open therapeutic avenues to prevent further hearing loss.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Bubble dynamics measurements using four-point optical probe
    Xue, JL
    Al-Dahhan, M
    Dudukovic, MP
    Mudde, RF
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 81 (3-4): : 375 - 381
  • [22] Performing Repeated Intraoperative Impedance Telemetry Measurements during Cochlear Implantation
    Weiss, Nora M.
    Hans, Stefan
    Wozniak, Martin
    Foeger, Aline
    Dazert, Stefan
    Van Rompaey, Vincent
    Van de Heyning, Paul
    Schmutzhard, Joachim
    Dierker, Angelika
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (198):
  • [23] Impedance Measures During in vitro Cochlear Implantation Predict Array Positioning
    Giardina, Christopher Kenneth
    Krause, Elliot Samuel
    Koka, Kanthaiah
    Fitzpatrick, Douglas Carl
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (02) : 327 - 335
  • [24] Improved thermoelectric power measurements using a four-point technique
    Corcoran, J.
    Raja, S.
    Nagy, P. B.
    NDT & E INTERNATIONAL, 2018, 94 : 92 - 100
  • [25] Evolution of energy dissipation during four-point bending of bituminous mixtures
    Varma, Remya K.
    Padmarekha, A.
    Ravindran, Parag
    Bahia, H. U.
    Krishnan, J. M.
    ROAD MATERIALS AND PAVEMENT DESIGN, 2017, 18 : 252 - 263
  • [26] Evaluation of Cancer Cell Lines by Four-Point Probe Technique, by Impedance Measurements in Various Frequencies
    Paivana, Georgia
    Barmpakos, Dimitris
    Mavrikou, Sophie
    Kallergis, Alexandros
    Tsakiridis, Odysseus
    Kaltsas, Grigoris
    Kintzios, Spyridon
    BIOSENSORS-BASEL, 2021, 11 (09):
  • [27] Experimental limitations in impedance spectroscopy .6. Four-point measurements of solid materials systems
    Hsieh, G
    Ford, SJ
    Mason, TO
    Pederson, LR
    SOLID STATE IONICS, 1997, 100 (3-4) : 297 - 311
  • [28] Four-point electrode measurement of impedance in the vicinity of bovine aorta for quasi-static frequencies
    Stiles, DK
    Oakley, BA
    BIOELECTROMAGNETICS, 2005, 26 (01) : 54 - 58
  • [29] Shear characterization of sandwich core materials using four-point bending
    Juntikka, Rickard
    Hallstrom, Stefan
    JOURNAL OF SANDWICH STRUCTURES & MATERIALS, 2007, 9 (01) : 67 - 94
  • [30] NUMERICAL SIMULATION OF AN ICE BEAM IN FOUR-POINT BENDING USING SPH
    Das, Jitapriya
    Polic, Drazen
    Ehlers, Soren
    Amdahl, Jorgen
    33RD INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2014, VOL 10: POLAR AND ARCTIC SCIENCE AND TECHNOLOGY, 2014,