Microstructure and Mechanical Characteristics of Ti-Ta Alloys before and after NaOH Treatment and Their Behavior in Simulated Body Fluid

被引:2
|
作者
Hulka, Iosif [1 ,2 ]
Mirza-Rosca, Julia Claudia [1 ]
Buzdugan, Dragos [3 ]
Saceleanu, Adriana [4 ]
机构
[1] Las Palmas de Gran Canaria Univ, Dept Mech Engn, Las Palmas Gran Canaria 35017, Spain
[2] Politehn Univ Timisoara, Res Inst Renewable Energy, 138 Gavril Musicescu St, Timisoara 300774, Romania
[3] Politehn Univ Timisoara, Dept Mat & Mfg Engn, Piata Victoriei 2, Timisoara 300006, Romania
[4] Lucian Blaga Univ Sibiu, Med Fac, Sibiu 550024, Romania
关键词
biomaterials; mechanical properties; alkali treatment; titanium-tantalum alloys; HYDROXYAPATITE COATINGS; TITANIUM-ALLOYS; ELASTIC-MODULUS; DEPOSITION;
D O I
10.3390/ma16051943
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In the present study, the microstructure and mechanical properties of Ti-xTa (x = 5%, 15%, and 25% wt. Ta) alloys produced by using an induced furnace by the cold crucible levitation fusion technique were investigated and compared. The microstructure was examined by scanning electron microscopy and X-ray diffraction. The alloys present a microstructure characterized by the alpha ' lamellar structure in a matrix of the transformed beta phase. From the bulk materials, the samples for the tensile tests were prepared and based on the results and the elastic modulus was calculated by deducting the lowest values for the Ti-25Ta alloy. Moreover, a surface alkali treatment functionalization was performed using 10 M NaOH. The microstructure of the new developed films on the surface of the Ti-xTa alloys was investigated by scanning electron microscopy and the chemical analysis revealed the formation of sodium titanate and sodium tantanate along with titanium and tantalum oxides. Using low loads, the Vickers hardness test revealed increased hardness values for the alkali-treated samples. After exposure to simulated body fluid, phosphorus and calcium were identified on the surface of the new developed film, indicating the development of apatite. The corrosion resistance was evaluated by open cell potential measurements in simulated body fluid before and after NaOH treatment. The tests were performed at 22 degrees C as well as at 40 degrees C, simulating fever. The results show that the Ta content has a detrimental effect on the investigated alloys' microstructure, hardness, elastic modulus, and corrosion behavior.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Effect of solid solution and aging treatment on the microstructure, mechanical properties, corrosion behavior and antimicrobial properties of Ti-5Mn alloys
    Xie, YanChun
    Wang, Xiaodong
    Xuan, Anwu
    Li, Yangyang
    Yu, Hailong
    Zhang, Erlin
    MATERIALS RESEARCH EXPRESS, 2024, 11 (06)
  • [32] Microstructure and Characteristics of Calcium Phosphate Layers on Bioactive Oxide Surfaces of Air-Sintered Titanium Foams after Immersion in Simulated Body Fluid
    Lee, Hung-Bin
    Hsu, Hsueh-Chuan
    Wu, Shih-Ching
    Hsu, Shih-Kuang
    Wang, Peng-Hsiang
    Ho, Wen-Fu
    MATERIALS, 2016, 9 (12)
  • [33] Research of Dynamic Corrosion Behavior, Microstructure, and Biocompatibility of Mg-Zn-Ca-Zr Alloys in Simulated Body Fluid Solution Induced by Zn Element Addition
    Cao, Xin
    Li, Chao
    Wu, Bing
    Liang, Ming
    ADVANCED ENGINEERING MATERIALS, 2023, 25 (08)
  • [34] Effect of Acid Treatment on the Surface Modification of Ti-6Al-7Nb and Ti-5Al-2Nb-1Ta and Its Electrochemical Investigations in Simulated Body Fluid
    Sasikumar Y.
    Rajendran N.
    Rajendran, N. (nrajendran@annauniv.edu), 1600, Springer International Publishing (03):
  • [35] Investigation of the wear and corrosion behaviors of Ti5Al2.5Fe and Ti6Al4V alloys produced by mechanical alloying method in simulated body fluid environment
    Simsek, Ijlal
    Ozyurek, Dursun
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 94 : 357 - 363
  • [36] Effects of heat treatment and load on frictional wear characteristics of β-type Ti-Nb-Ta-Zr system alloy for biomedical applications in air and simulated body environment
    Akahori, Toshikazu
    Niinomi, Mitsuo
    Watanabe, Manabu
    Nakai, Masaaki
    Fukui, Hisao
    Ogawa, Michiharu
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 2007, 71 (04) : 407 - 414
  • [37] Investigation of the microstructural characteristics of laser-cladded Ti6Al4V titanium alloy and its corrosion behavior in simulated body fluid
    Qin, Xudong
    Yang, Huaxing
    Zhao, Yang
    Wan, Siyan
    Zhao, Xinyang
    Yu, Tao
    Wang, Xiaoming
    Zhang, Zhao
    MATERIALS TODAY COMMUNICATIONS, 2024, 41
  • [38] Influence of Thermal Treatment on the Microstructure, Mechanical Properties, and Corrosion Resistance of Newly Developed Ti20Nb13Zr Biomedical Alloy in a Simulated Body Environment
    Hussein, M. A.
    Azeem, M.
    Kumar, A. Madhan
    Al-Aqeeli, N.
    Ankah, N. K.
    Sorour, A. A.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2019, 28 (03) : 1337 - 1349
  • [39] Influence of Thermal Treatment on the Microstructure, Mechanical Properties, and Corrosion Resistance of Newly Developed Ti20Nb13Zr Biomedical Alloy in a Simulated Body Environment
    M. A. Hussein
    M. Azeem
    A. Madhan Kumar
    N. Al-Aqeeli
    N. K. Ankah
    A. A. Sorour
    Journal of Materials Engineering and Performance, 2019, 28 : 1337 - 1349
  • [40] Investigation on microstructure, mechanical properties and corrosion behavior of Sc-contained Al-7075 alloys after solution-aging treatment
    Deng, Jinzhao
    Shen, Jun
    Li, Hao
    Chen, Hui
    Xie, Fuxing
    MATERIALS RESEARCH EXPRESS, 2020, 7 (09)