Microstructure and Mechanical Characteristics of Ti-Ta Alloys before and after NaOH Treatment and Their Behavior in Simulated Body Fluid

被引:2
|
作者
Hulka, Iosif [1 ,2 ]
Mirza-Rosca, Julia Claudia [1 ]
Buzdugan, Dragos [3 ]
Saceleanu, Adriana [4 ]
机构
[1] Las Palmas de Gran Canaria Univ, Dept Mech Engn, Las Palmas Gran Canaria 35017, Spain
[2] Politehn Univ Timisoara, Res Inst Renewable Energy, 138 Gavril Musicescu St, Timisoara 300774, Romania
[3] Politehn Univ Timisoara, Dept Mat & Mfg Engn, Piata Victoriei 2, Timisoara 300006, Romania
[4] Lucian Blaga Univ Sibiu, Med Fac, Sibiu 550024, Romania
关键词
biomaterials; mechanical properties; alkali treatment; titanium-tantalum alloys; HYDROXYAPATITE COATINGS; TITANIUM-ALLOYS; ELASTIC-MODULUS; DEPOSITION;
D O I
10.3390/ma16051943
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In the present study, the microstructure and mechanical properties of Ti-xTa (x = 5%, 15%, and 25% wt. Ta) alloys produced by using an induced furnace by the cold crucible levitation fusion technique were investigated and compared. The microstructure was examined by scanning electron microscopy and X-ray diffraction. The alloys present a microstructure characterized by the alpha ' lamellar structure in a matrix of the transformed beta phase. From the bulk materials, the samples for the tensile tests were prepared and based on the results and the elastic modulus was calculated by deducting the lowest values for the Ti-25Ta alloy. Moreover, a surface alkali treatment functionalization was performed using 10 M NaOH. The microstructure of the new developed films on the surface of the Ti-xTa alloys was investigated by scanning electron microscopy and the chemical analysis revealed the formation of sodium titanate and sodium tantanate along with titanium and tantalum oxides. Using low loads, the Vickers hardness test revealed increased hardness values for the alkali-treated samples. After exposure to simulated body fluid, phosphorus and calcium were identified on the surface of the new developed film, indicating the development of apatite. The corrosion resistance was evaluated by open cell potential measurements in simulated body fluid before and after NaOH treatment. The tests were performed at 22 degrees C as well as at 40 degrees C, simulating fever. The results show that the Ta content has a detrimental effect on the investigated alloys' microstructure, hardness, elastic modulus, and corrosion behavior.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Effect of surface treatment on electrochemical behavior of CPTi, Ti-6Al-4V and Ti-13Nb-13Zr alloys in simulated human body fluid
    Shukla, A. K.
    Balasubramaniam, R.
    CORROSION SCIENCE, 2006, 48 (07) : 1696 - 1720
  • [22] Development of Rapid Bioactivity-Expressed Zr-50Ti Alloys by Surface Treatment with Modified Simulated Body Fluid
    Wu, Yuwei
    Takai, Shigeomi
    Yabutsuka, Takeshi
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2024, 25 (12)
  • [23] Effect of heat treatment on the microstructure and mechanical properties of biocompatible Ti-Ta-Nb-Zr alloys prepared by selective laser melting
    Zhang, Kai
    Zhong, Ning
    Zhang, Xianjin
    Wen, Chen
    Zhou, Yun
    Lu, Shangwen
    INTERNATIONAL JOURNAL OF MATERIALS RESEARCH, 2024, 115 (05) : 349 - 358
  • [24] Effect of Zn content and heat treatment on tribological behavior of biodegradable Mg-xZn alloys in simulated body fluid
    Koc, Erkan
    Turan, Muhammet Emre
    MATERIALS RESEARCH EXPRESS, 2019, 6 (08)
  • [25] Research on Dynamic Corrosion Behavior and the Microstructure of Biomedical Mg-Y-Zn-Zr-Sr in Simulated Body Fluid Solution after Processing by Solution Treatment
    Cao, Xin
    Jia, Qinggong
    Xu, Chunxiang
    Zhang, Zhengwei
    Ren, Conglin
    Yang, Wenfu
    Zhang, Jinshan
    ADVANCED ENGINEERING MATERIALS, 2020, 22 (05)
  • [26] Frictional wear characteristics of biomedical Ti-29Nb-13Ta-4.6Zr alloy with various microstructures in air and simulated body fluid
    Niinomi, Mitsuo
    Nakai, Masaaki
    Akahori, Toshikazu
    BIOMEDICAL MATERIALS, 2007, 2 (03) : S167 - S174
  • [27] Effects of alloying elements and annealing treatment on the microstructure and mechanical properties of Nb-Ta-Ti alloys fabricated by partial diffusion for biomedical applications
    Liu, Jue
    Yang, Qiumin
    Yin, Jian
    Yang, Hailin
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 110
  • [28] Microstructure-dependent corrosion fatigue crack growth behavior of Ti-6Al-4V alloy in simulated body fluid
    Zhao, Xiaotong
    Song, Xiu
    Wang, Ran
    Wang, Lei
    Liu, Yang
    Hu, Jiali
    ENGINEERING FAILURE ANALYSIS, 2023, 148
  • [29] Mechanical properties and corrosion behavior of novel β-type biomaterial Zr-6Mo-4Ti-xY alloys in simulated body fluid Ringer's lactate solution for implant applications
    Awwaluddin, Muhammad
    Prajitno, Djoko Hadi
    Adi, Wisnu Ari
    Kartaman, Maman
    Soemardi, Tresna P.
    AIMS MATERIALS SCIENCE, 2020, 7 (06) : 887 - 901
  • [30] A comparative study on the tribological behavior of Ti-6Al-4V and Ti-24Nb-4Zr-8Sn alloys in simulated body fluid
    Injetia, V. S. Y.
    Nune, K. C.
    Reyes, E.
    Yue, G.
    Li, S. J.
    Misra, R. D. K.
    MATERIALS TECHNOLOGY, 2019, 34 (05) : 270 - 284