Pullout Performance of Timber Joints with Glued-In Steel Rods at an Angle to the Grain

被引:2
|
作者
Xu, Bo-Han [1 ]
Jiao, Shi-Yuan [1 ]
Li, Dong-Feng [1 ]
Bouchair, Abdelhamid [2 ]
Zhang, Binsheng [3 ]
机构
[1] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[2] Univ Clermont Auvergne, CNRS, Inst Pascal, Clermont Auvergne Inst Natl Polytech INP, F-63000 Clermont Ferrand, France
[3] Glasgow Caledonian Univ, Sch Comp Engn & Built Environm, Dept Civil Engn & Environm Management, Glasgow G4 0BA, Scotland
关键词
Pullout performance; Glued-in rods; Rod-to-grain angle; Pull-pull loading; Pull-beam loading; OUT STRENGTH; GLULAM PARALLEL; CONNECTIONS; BEHAVIOR;
D O I
10.1061/JMCEE7.MTENG-16401
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Glued-in rods in timber joints are efficient to transfer axial forces, and their pullout performances are not only related to the anchorage length, rod diameter, and glue-line thickness, but also to the angle of the rod to the grain-or the rod-to-grain angle. The limited available results on the effect of the rod-to-grain angle from literature are mostly based on the pullout tests with short anchorage lengths under the pull-compression loading, which do not correspond with the practical applications of glued-in rods. This paper explored the pullout performances of the glued-in rods with an anchorage length 10 times the rod diameter at 0 degrees (parallel) to the grain under pull-pull loading pattern, and at 30 degrees, 45 degrees, 60 degrees, and 90 degrees (perpendicular) to the grain under pull-beam loading patterns, which are closer to practice than pull-compression loading pattern. The pullout capacity and slip modulus of timber joints with the glued-in rods parallel to the grain were greater than those at an angle to the grain. The empirical formulas were derived from the experimental results to predict the pullout capacities and slip moduli of the glued-in rods at an angle to the grain using the pullout capacity and slip modulus of the glued-in rods parallel to the grain.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Systems that improve the behaviour of joints made using glued-in rods
    Otero-Chans, D.
    Estevez-Cimadevila, J.
    Martin-Gutierrez, E.
    Suarez-Riestra, F.
    EUROPEAN JOURNAL OF WOOD AND WOOD PRODUCTS, 2019, 77 (06) : 1079 - 1093
  • [42] Timber structures with connections based on in v-form glued-in rods
    Kangas, J
    Kevarinmäki, A
    Lumiaho, H
    INNOVATIVE WOODEN STRUCTURES AND BRIDGES, 2001, : 585 - 590
  • [43] Cyclic Loading of Glued-In FRP Rods in Timber: Experimental and Analytical Study
    Toumpanaki, Eleni
    Ramage, Michael
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2022, 26 (02)
  • [44] Glued-in rods in cross laminated timber - Numerical simulations and parametric studies
    Azinovic, Boris
    Danielsson, Henrik
    Serrano, Erik
    Kramar, Miha
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 212 : 431 - 441
  • [45] Experimental investigation of the axial strength of glued-in rods in cross laminated timber
    Boris Azinović
    Erik Serrano
    Miha Kramar
    Tomaž Pazlar
    Materials and Structures, 2018, 51
  • [46] Experimental investigation of the axial strength of glued-in rods in cross laminated timber
    Azinovic, Boris
    Serrano, Erik
    Kramar, Miha
    Pazlar, Tomaz
    MATERIALS AND STRUCTURES, 2018, 51 (06)
  • [48] Experimental test of threaded steel rods glued-in hardwood with epoxy
    Otero, D.
    Estevez, J.
    Martin, E.
    Vazquez, J. A.
    HIGH PERFORMANCE STRUCTURES AND MATERIALS III, 2006, 85 : 63 - +
  • [49] Durability of joints made with threaded steel rods glued in chestnut timber - An experimental approach
    Martin-Gutierrez, E.
    Estevez-Cimadevila, J.
    Otero-Chans, D.
    COMPOSITES PART B-ENGINEERING, 2017, 108 : 413 - 419
  • [50] Correction to: Experimental investigation of the axial strength of glued-in rods in cross laminated timber
    Boris Azinović
    Erik Serrano
    Miha Kramar
    Tomaž Pazlar
    Materials and Structures, 2019, 52