Pullout Performance of Timber Joints with Glued-In Steel Rods at an Angle to the Grain

被引:2
|
作者
Xu, Bo-Han [1 ]
Jiao, Shi-Yuan [1 ]
Li, Dong-Feng [1 ]
Bouchair, Abdelhamid [2 ]
Zhang, Binsheng [3 ]
机构
[1] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[2] Univ Clermont Auvergne, CNRS, Inst Pascal, Clermont Auvergne Inst Natl Polytech INP, F-63000 Clermont Ferrand, France
[3] Glasgow Caledonian Univ, Sch Comp Engn & Built Environm, Dept Civil Engn & Environm Management, Glasgow G4 0BA, Scotland
关键词
Pullout performance; Glued-in rods; Rod-to-grain angle; Pull-pull loading; Pull-beam loading; OUT STRENGTH; GLULAM PARALLEL; CONNECTIONS; BEHAVIOR;
D O I
10.1061/JMCEE7.MTENG-16401
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Glued-in rods in timber joints are efficient to transfer axial forces, and their pullout performances are not only related to the anchorage length, rod diameter, and glue-line thickness, but also to the angle of the rod to the grain-or the rod-to-grain angle. The limited available results on the effect of the rod-to-grain angle from literature are mostly based on the pullout tests with short anchorage lengths under the pull-compression loading, which do not correspond with the practical applications of glued-in rods. This paper explored the pullout performances of the glued-in rods with an anchorage length 10 times the rod diameter at 0 degrees (parallel) to the grain under pull-pull loading pattern, and at 30 degrees, 45 degrees, 60 degrees, and 90 degrees (perpendicular) to the grain under pull-beam loading patterns, which are closer to practice than pull-compression loading pattern. The pullout capacity and slip modulus of timber joints with the glued-in rods parallel to the grain were greater than those at an angle to the grain. The empirical formulas were derived from the experimental results to predict the pullout capacities and slip moduli of the glued-in rods at an angle to the grain using the pullout capacity and slip modulus of the glued-in rods parallel to the grain.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Flexural performance of glulam timber beams with glued-in BFRP rods connections
    Jemaa, Yaser
    Yeboah, David
    Gkantou, Michaela
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 443
  • [22] Provisions for Ductile Behavior of Timber-to-Steel Connections with Multiple Glued-In Rods
    Parida, Gabriela
    Johnsson, Helena
    Fragiacomo, Massimo
    JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (09) : 1468 - 1477
  • [23] Mixed mode fracture of glued-in rods in timber structures
    Lartigau, Julie
    Coureau, Jean-Luc
    Morel, Stephane
    Galimard, Philippe
    Maurin, Emmanuel
    INTERNATIONAL JOURNAL OF FRACTURE, 2015, 192 (01) : 71 - 86
  • [24] EXPERIMENTAL TESTS OF TIMBER CONNECTIONS WITH GLUED-IN RODS IN BENDING
    Duchon, Vladimir
    Klas, Tomas
    Katona, Orsolya
    Brodniansky, Jan
    Balcierak, Lubos
    Sandanus, Jaroslav
    Sogel, Kristian
    WOOD RESEARCH, 2016, 61 (04) : 565 - 572
  • [25] Experimental investigation of joints with multiple glued-in rods in glued-laminated timber under axial tensile loading
    Bouchard, Raphael
    Salenikovich, Alexander
    Frenette, Caroline
    Bedard-Blanchet, Guillaume
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 293
  • [26] Experimental tests of timber connections with glued-in rods in bending
    Duchoň, Vladimír (rvladimirduchon@gmail.com), 1600, Pulp and Paper Research Institute (61):
  • [27] New joint design for the improvement of steel rods glued-in timber using an adhesive bulb
    Estevez, J.
    Otero, D.
    Martin, E.
    Vazquez, J. A.
    STRUCTURES AND ARCHITECTURE, 2010, : 1117 - 1124
  • [28] Shear strength of beam splice joints with glued-in rods
    Jørgen Lauritzen Jensen
    Per-Johan Gustafsson
    Journal of Wood Science, 2004, 50 : 123 - 129
  • [29] Distributed fiber optic strain sensing in axially loaded glued-in steel rods in glued-laminated timber
    Ernewein, Benjamin
    Woods, Joshua E.
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 392
  • [30] Glued-in rods for timber structures—An experimental study of softening behaviour
    E. Serrano
    Materials and Structures, 2001, 34 : 228 - 234