A deep-learning method using single phantom to enhance megavoltage image quality for patient positioning in chest radiotherapy: a feasibility study

被引:0
|
作者
Jeon, Hosang [1 ,2 ]
Kim, Dong Woon [1 ,2 ]
Joo, Ji Hyeon [1 ,2 ,3 ]
Ki, Yongkan [1 ,2 ,3 ]
Kim, Wontaek [3 ,4 ]
Park, Dahl [4 ]
Nam, Jiho [4 ]
Kim, Dong Hyeon [3 ,4 ]
机构
[1] Pusan Natl Univ, Dept Radiat Oncol, Yangsan Hosp, Yangsan, South Korea
[2] Pusan Natl Univ, Res Inst Convergence Biomed Sci & Technol, Yangsan Hosp, Yangsan, South Korea
[3] Pusan Natl Univ, Dept Radiat Oncol, Sch Med, Yangsan, South Korea
[4] Pusan Natl Univ Hosp, Dept Radiat Oncol, Pusan, South Korea
基金
新加坡国家研究基金会;
关键词
Deep learning; Megavoltage image; Kilovoltage image; Radiotherapy; Patient setup;
D O I
10.1007/s40042-023-00852-4
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Image-guided radiation treatment (IGRT) is essential for verifying patient positioning during modern radiotherapy. Although megavoltage digital radiographs (MV-DR) are available on most therapeutic linear accelerators and can be used for checking treatment beam shapes, they are much inferior to kilovoltage digital radiographs (KV-DR) in terms of image quality. As it is generally challenging to obtain a well-aligned MV - KV training dataset of patients in clinical scenarios, there is a lack of sufficient information on the accuracy of KV-DR synthesized using supervised training. Therefore, we aimed to synthesize pseudo KV-DR (pKV-DR) from MV-DR using a training dataset developed with a single anthropomorphic chest phantom. The phantom was adopted to obtain MV - KV image pairs at various gantry angles because these image pairs of patients are highly difficult to acquire and exactly align with each other. A deep-learning model based on U-net architecture was trained with the phantom image pairs using the mean absolute error (MAE) and structure similarity (SSIM) indices as loss functions. The mean MAEs of MV-DR and pKV-DR against KV-DR as the ground truth were 0.1152 and 0.0169, respectively, and their mean SSIM values were 0.9693 and 0.9942, respectively. Finally, pKV-DR showed a relatively high image similarity to that of KV-DR with smaller MAE (14.7%) and higher SSIM (2.5%), compared with MV-DR. The image contrast was also improved by 37.1% in clinical cases. The proposed method is expected to enable the implementation of improved IGRT with high image quality of KV-DR level, even in clinics where MV-DR is only available.
引用
收藏
页码:72 / 80
页数:9
相关论文
共 50 条
  • [31] Improving CBCT Quality to CT Level Using Deep-Learning Method for Adaptive Radiation Therapy
    Zhang, Y.
    Yue, N.
    Su, M.
    Ding, Y.
    Liu, B.
    Zhang, Y.
    Zhou, Y.
    Nie, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E186 - E186
  • [32] Predicting X-ray Diffraction Quality of Protein Crystals Using a Deep-Learning Method
    Shen, Yujian
    Zhu, Zhongjie
    Xiao, Qingjie
    Ye, Kanglei
    Wang, Qisheng
    Wang, Yue
    Sun, Bo
    CRYSTALS, 2024, 14 (09)
  • [33] Effect of Tube Voltage and Radiation Dose on Image Quality in Pediatric Abdominal CT Using Deep Learning Reconstruction: A Phantom Study
    Kim, Daehong
    Jeon, Pil-Hyun
    Lee, Chang-Lae
    Chung, Myung-Ae
    SYMMETRY-BASEL, 2023, 15 (02):
  • [34] Patient-Specific Quality Assurance Using a 3D-Printed Chest Phantom for Intraoperative Radiotherapy in Breast Cancer
    Choi, Yeonho
    Lee, Ik Jae
    Park, Kwangwoo
    Park, Kyung Ran
    Cho, Yeona
    Kim, Jun Won
    Lee, Ho
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [35] Comparison of two versions of a deep learning image reconstruction algorithm on CT image quality and dose reduction: A phantom study
    Greffier, Joel
    Dabli, Djamel
    Frandon, Julien
    Hamard, Aymeric
    Belaouni, Asmaa
    Akessoul, Philippe
    Fuamba, Yannick
    Le Roy, Julien
    Guiu, Boris
    Beregi, Jean-Paul
    MEDICAL PHYSICS, 2021, 48 (10) : 5743 - 5755
  • [36] Deep learning based ultra-low dose fan-beam computed tomography image enhancement algorithm: Feasibility study in image quality for radiotherapy
    Jiang, Hua
    Qin, Songbing
    Jia, Lecheng
    Wei, Ziquan
    Xiong, Weiqi
    Xu, Wentao
    Gong, Wei
    Zhang, Wei
    Yu, Liqin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024,
  • [37] Evaluation of Ultra-low-dose (ULD) Lung Computed Tomography (CT) Using Deep-learning: A Phantom Study
    Kim, Daehong
    Son, Kihong
    Baek, Cheol-Ha
    Jeon, Pil-Hyun
    Lee, Sooyeul
    JOURNAL OF MAGNETICS, 2021, 26 (04) : 429 - 436
  • [38] Feasibility Study of Log-Based Pre-Treatment Quality Assurance Without Dry-Run Using the Deep-Learning Approach
    Cheon, W.
    Han, Y.
    Kim, W.
    Min, B.
    MEDICAL PHYSICS, 2019, 46 (06) : E633 - E633
  • [39] Denoising method for image quality improvement in photoacoustic microscopy using deep learning
    Yu, Ziming
    Tang, Kanggao
    Song, Xianlin
    COMPUTATIONAL OPTICS 2021, 2021, 11875
  • [40] Image quality dependency on system configuration and tube voltage in chest tomosynthesis-A visual grading study using an anthropomorphic chest phantom
    Soderman, Christina
    Asplund, Sara
    Johnsson, Ase Allansdotter
    Vikgren, Jenny
    Norrlund, Rauni Rossi
    Molnar, David
    Svalkvist, Angelica
    Mansson, Lars Gunnar
    Bath, Magnus
    MEDICAL PHYSICS, 2015, 42 (03) : 1200 - 1212