Deep learning based ultra-low dose fan-beam computed tomography image enhancement algorithm: Feasibility study in image quality for radiotherapy

被引:0
|
作者
Jiang, Hua [1 ]
Qin, Songbing [1 ]
Jia, Lecheng [2 ,4 ]
Wei, Ziquan [2 ]
Xiong, Weiqi [3 ]
Xu, Wentao [1 ]
Gong, Wei [1 ]
Zhang, Wei [3 ]
Yu, Liqin [1 ]
机构
[1] Soochow Univ, Affiliated Hosp 1, Dept Radiat Oncol, Suzhou, Peoples R China
[2] Shenzhen United Imaging Res Inst Innovat Med Equip, Real Time Lab, Shenzhen, Peoples R China
[3] Shanghai United Imaging Healthcare Co Ltd, Radiotherapy Business Unit, Shanghai, Peoples R China
[4] Zhejiang Engn Res Ctr Innovat & Applicat Intellige, Wenzhou, Peoples R China
关键词
deep learning; fan-beam CT; image quality; image-guided radiotherapy; ultra-low dose CT; GUIDED ADAPTIVE RADIOTHERAPY; ITERATIVE RECONSTRUCTION; ABDOMINAL CT; RADIATION; EXPOSURE; NOISE;
D O I
10.1002/acm2.14560
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: We investigated the feasibility of deep learning-based ultra-low dose kV-fan-beam computed tomography (kV-FBCT) image enhancement algorithm for clinical application in abdominal and pelvic tumor radiotherapy. Methods: A total of 76 patients of abdominal and pelvic tumors were prospectively selected. The Catphan504 was acquired with the same conditions as the standard phantom test set. We used a CycleGAN-based model for image enhancement. Normal dose CT (NDCT), ultra-low dose CT (LDCT) and deep learning enhanced CT (DLR) were evaluated by subjective and objective analyses in terms of imaging quality, HU accuracy, and image signal-to-noise ratio (SNR). Results: The image noise of DLR was significantly reduced, and the contrast-to-noise ratio (CNR) was significantly improved compared to the LDCT. The most significant improvement was the acrylic which represented soft tissue in CNR from 1.89 to 3.37, improving by 76%, nearly approaching the NDCT, and in low-density resolution from 7.64 to 12.6, improving by 64%. The spatial frequencies of MTF10 and MTF50 in DLR were 4.28 and 2.35 cycles/mm in DLR, respectively, which are higher than LDCT 3.87 and 2.12 cycles/mm, and even slightly higher than NDCT 4.15 and 2.28 cycles/mm. The accuracy and stability of HU values of DLR were similar to NDCT. The image quality evaluation of the two doctors agreed well with DLR and NDCT. A two-by-two comparison between groups showed that the differences in image scores of LDCT compared with NDCT and DLR were all statistically significant (p < 0.05), and the subjective scores of DLR were close to NDCT. Conclusion: The image quality of DLR was close to NDCT with reduced radiation dose, which can fully meet the needs of conventional image-guided adaptive radiotherapy (ART) and achieve the quality requirements of clinical radiotherapy. The proposed method provided a technical basis for LDCT-guided ART.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Concept for a Fan-beam Computed Tomography Image-guided Radiotherapy Device
    Weidlich, Vincent
    Lechuga, Lawrence
    Dore, Dennis
    Weidlich, Georg A.
    Nighan, Bill
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (06)
  • [2] Evaluation of fan-beam kilovoltage computed tomography image quality on a novel biological-guided radiotherapy platform
    Zhuang, Tingliang
    Gibbard, Grant
    Duan, Xinhui
    Tan, Jun
    Park, Yang
    Lin, Mu -Han
    Sun, Zhihui
    Oderinde, Oluwaseyi M.
    Lu, Weiguo
    Reynolds, Robert
    Godley, Andrew
    Pompos, Arnold
    Dan, Tu
    Garant, Aurelie
    Iyengar, Puneeth
    Timmerman, Robert
    Jiang, Steve
    Cai, Bin
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 26
  • [3] Ultra-low dose chest computed tomography: Effect of iterative reconstruction levels on image quality
    Afadzi, Mercy
    Lysvik, Elisabeth Kirkeby
    Andersen, Hilde Kjernlie
    Martinsen, Anne Catrine T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 114 : 62 - 68
  • [4] Preliminary investigation of a new algorithm for image reconstruction in half-scan fan-beam computed tomography
    Yu, LF
    Pan, XC
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 979 - 983
  • [5] The influence of a deep learning image reconstruction algorithm on the image quality and auto-analysis of pulmonary nodules at ultra-low dose chest CT: a phantom study
    Yao, Yue
    Guo, Baobin
    Li, Jianying
    Yang, Quanxin
    Li, Xiaohui
    Deng, Lei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (05) : 2777 - 2791
  • [6] Deep learning image reconstruction algorithm: impact on image quality in coronary computed tomography angiography
    Domenico De Santis
    Tiziano Polidori
    Giuseppe Tremamunno
    Carlotta Rucci
    Giulia Piccinni
    Marta Zerunian
    Luca Pugliese
    Antonella Del Gaudio
    Gisella Guido
    Luca Barbato
    Andrea Laghi
    Damiano Caruso
    La radiologia medica, 2023, 128 : 434 - 444
  • [7] Deep learning image reconstruction algorithm: impact on image quality in coronary computed tomography angiography
    De Santis, Domenico
    Polidori, Tiziano
    Tremamunno, Giuseppe
    Rucci, Carlotta
    Piccinni, Giulia
    Zerunian, Marta
    Pugliese, Luca
    Del Gaudio, Antonella
    Guido, Gisella
    Barbato, Luca
    Laghi, Andrea
    Caruso, Damiano
    RADIOLOGIA MEDICA, 2023, 128 (04): : 434 - 444
  • [8] Evaluation of Ultra-low-dose Paediatric Cone-beam Computed Tomography for Image-guided Radiotherapy
    Bryce-Atkinson, A.
    de Jong, R.
    Bel, A.
    Aznar, M. C.
    Whitfield, G.
    van Herk, M.
    CLINICAL ONCOLOGY, 2020, 32 (12) : 835 - 844
  • [9] Deep learning-based image quality improvement for low-dose computed tomography simulation in radiation therapy
    Wang, Tonghe
    Lei, Yang
    Tian, Zhen
    Dong, Xue
    Liu, Yingzi
    Jiang, Xiaojun
    Curran, Walter J.
    Liu, Tian
    Shu, Hui-Kuo
    Yang, Xiaofeng
    JOURNAL OF MEDICAL IMAGING, 2019, 6 (04)
  • [10] Priori mask guided image reconstruction (p-MGIR) for ultra-low dose cone-beam computed tomography
    Park, Justin C.
    Zhang, Hao
    Chen, Yunmei
    Fan, Qiyong
    Kahler, Darren L.
    Liu, Chihray
    Lu, Bo
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21): : 8505 - 8524