Retention of titanium copings to implant-supported fixed dental prostheses

被引:3
|
作者
Chiam, Sieu Yien [1 ]
Lee, Hsin Lin [2 ]
Bedrossian, Armand E. [1 ]
Xu, Qianhui [3 ]
Kuykendall, William [4 ]
Ren, Anna [1 ]
Hess, Timothy A. [1 ]
Ramos Jr, Van [1 ]
Chung, Kwok-Hung [1 ,5 ]
机构
[1] Univ Washington, Sch Dent, Dept Restorat Dent, Grad Prosthodont, Seattle, WA USA
[2] Univ Washington, Sch Dent, Dept Oral Hlth Sci, Seattle, WA USA
[3] Columbia Univ, Dept Epidemiol, Mailman Sch Publ Hlth, New York, NY USA
[4] Univ Washington, Mech Engn Dept, Seattle, WA USA
[5] Univ Washington, Dept Restorat Dent, 1959 NE Pacific St, HSC-D770Box,357456, Seattle, WA 98195 USA
关键词
cement; implant-supported fixed complete dental prostheses; prepolymerized denture acrylic resin; titanium base; zirconia; IN-VITRO; CROWNS; ABUTMENTS; SURVIVAL; PROTOCOL; STRENGTH; BASES;
D O I
10.1111/jopr.13706
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeThe aim of this in vitro study was to assess the effects of using different cements and titanium copings designs on the retention of implant-supported fixed dental prostheses (IFDPs) using a pull-out test. Materials and MethodsFifty zirconia (ZirCAD; Ivoclar Vivadent) and 20 prepolymerized denture acrylic resin (AvaDent) rectangular (36 mm x 12 mm x 8 mm) specimens were milled to mimic the lower left segmental portion of the All-on-Four IFDPs. Cylindrical titanium copings (Variobase; Straumann) (V) were used in 2 prepolymerized denture acrylic resin groups (n = 10) while conical titanium copings (Straumann) (C) were used as a control group for zirconia with 4 groups using cylindrical titanium copings. Before cementation, the outer surfaces of all titanium copings and the intaglio bonding surface of prosthetic specimens were airborne-particle abraded. All specimens were cemented following the manufacturer's recommendations and instructions according to the experimental design. After artificial aging (5000 cycles of 5 degrees C 55 degrees C, dwelling time 20 s; 150 N, 1.5 Hz in a 37 degrees C water bath), all specimens were subjected to retention force testing using a pull-out test using a universal testing machine and a custom fixture with a crosshead speed 5 mm/min. Modes of failure were classified as Type 1, 2, or 3. Retention force values were analyzed by the t-test for the prepolymerized denture acrylic resin specimen groups, and 1-way ANOVA and the Tukey test for the zirconia groups at alpha = 0.05. ResultsMean and standard deviation retention force values varied from 101.1 +/- 67.1 to 509.0 +/- 65.2 N for the prepolymerized denture acrylic resin specimen groups. The zirconia groups ranged from 572.8 +/- 274.7 to 1416.1 +/- 258.0 N. There is no statistically significant difference in retention force values between V and C specimens cementing to zirconia with Panavia SA cement (Kuraray Noritake) (p = 0.587). The retention forces and failure modes were influenced by the cement used (p < 0.05). Modes of failure were predominantly Type 2 (mixed failure) and Type 1 (adhesive fracture from prosthetic materials) except for the quick-set resin group (Type 3, adhesive failure from coping). ConclusionsWhen bonding IFDPs onto titanium copings, quick-set resin provided significantly higher retention force for prepolymerized denture acrylic resin prostheses. Conical and cylindrical titanium copings performed similarly when cemented to zirconia with Panavia SA cement under the same protocol. The stability of the bonded interface and retention forces between zirconia prostheses and titanium copings varied from the cement used.
引用
收藏
页码:340 / 347
页数:8
相关论文
共 50 条
  • [41] Fit of implant-supported fixed prostheses fabricated on master casts made from a dental stone and a dental plaster
    Wise, M
    JOURNAL OF PROSTHETIC DENTISTRY, 2001, 86 (05): : 532 - 538
  • [42] Strain Behavior of Implant-Supported Full-Arch Fixed Dental Prostheses Supported by Four or Five Implants
    Sbardelotto, Cristian
    Lapria Faria, Adriana Claudia
    Tiossi, Rodrigo
    Ribeiro, Ricardo Faria
    Silveira Rodrigues, Renata Cristina
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 153 - 158
  • [43] SURVIVAL OF FIXED IMPLANT-SUPPORTED PROSTHESES RELATED TO CANTILEVER LENGTHS
    SHACKLETON, JL
    CARR, L
    SLABBERT, JCG
    BECKER, PJ
    JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (01): : 23 - 26
  • [44] Treatment outcomes of patients with implant-supported fixed partial prostheses
    Wyatt, CCL
    Zarb, GA
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (02) : 204 - 211
  • [45] Implant-supported dental prostheses as a treatment concept in edentulous maxillae
    Rammelsberg, Peter
    IMPLANTOLOGIE, 2012, 20 (02): : 183 - 192
  • [46] Maintenance requirements of implant-supported fixed prostheses opposed by implant-supported fixed prostheses, natural teeth, or complete dentures: A 5-year retrospective study
    Davis, DM
    Packer, ME
    Watson, RM
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2003, 16 (05) : 521 - 523
  • [47] Evaluation of Retention Forces of Implant-Supported Zirconia Copings on Titanium Abutments Coated with Metal Opaquers Using Different Cements
    Lei, Wenlong
    Guo, Jingmei
    Du, Rui
    Shi, Bin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (02) : 339 - 345
  • [48] Partially digital workflow for making complete-arch implant-supported fixed prostheses: A dental technique
    Pereira, Ana Larisse Carneiro
    Campos, Maria de Fatima Trindade Pinto
    Freitas, Rodrigo Falcao Carvalho Porto de
    Torres, Ana Clara Soares Paiva
    Gomes, Jessica Marcela de Luna
    Pellizzer, Eduardo Piza
    Carreiro, Adriana da Fonte Porto
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (01): : 18 - 23
  • [49] Accuracy of Fixed Implant-Supported Dental Prostheses Additively Manufactured by Metal, Ceramic, or Polymer: A Systematic Review
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Auskalnis, Liudas
    Admakin, Oleg
    Mangano, Francesco
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 : 70 - 87
  • [50] Impact of Implant Angulation on Stress Distribution and Survival Rate of Implant-Supported Fixed Dental Prostheses: A Prospective Clinical Study
    Gajbhiye, Ojas Anand
    Parmar, Vishal B.
    Begum, Fouziya
    Hussaini, Syed Mehmood
    Chandra, Sarath
    Sonikumari
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 (SUPPL 4) : S3215 - S3217