Retention of titanium copings to implant-supported fixed dental prostheses

被引:3
|
作者
Chiam, Sieu Yien [1 ]
Lee, Hsin Lin [2 ]
Bedrossian, Armand E. [1 ]
Xu, Qianhui [3 ]
Kuykendall, William [4 ]
Ren, Anna [1 ]
Hess, Timothy A. [1 ]
Ramos Jr, Van [1 ]
Chung, Kwok-Hung [1 ,5 ]
机构
[1] Univ Washington, Sch Dent, Dept Restorat Dent, Grad Prosthodont, Seattle, WA USA
[2] Univ Washington, Sch Dent, Dept Oral Hlth Sci, Seattle, WA USA
[3] Columbia Univ, Dept Epidemiol, Mailman Sch Publ Hlth, New York, NY USA
[4] Univ Washington, Mech Engn Dept, Seattle, WA USA
[5] Univ Washington, Dept Restorat Dent, 1959 NE Pacific St, HSC-D770Box,357456, Seattle, WA 98195 USA
关键词
cement; implant-supported fixed complete dental prostheses; prepolymerized denture acrylic resin; titanium base; zirconia; IN-VITRO; CROWNS; ABUTMENTS; SURVIVAL; PROTOCOL; STRENGTH; BASES;
D O I
10.1111/jopr.13706
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeThe aim of this in vitro study was to assess the effects of using different cements and titanium copings designs on the retention of implant-supported fixed dental prostheses (IFDPs) using a pull-out test. Materials and MethodsFifty zirconia (ZirCAD; Ivoclar Vivadent) and 20 prepolymerized denture acrylic resin (AvaDent) rectangular (36 mm x 12 mm x 8 mm) specimens were milled to mimic the lower left segmental portion of the All-on-Four IFDPs. Cylindrical titanium copings (Variobase; Straumann) (V) were used in 2 prepolymerized denture acrylic resin groups (n = 10) while conical titanium copings (Straumann) (C) were used as a control group for zirconia with 4 groups using cylindrical titanium copings. Before cementation, the outer surfaces of all titanium copings and the intaglio bonding surface of prosthetic specimens were airborne-particle abraded. All specimens were cemented following the manufacturer's recommendations and instructions according to the experimental design. After artificial aging (5000 cycles of 5 degrees C 55 degrees C, dwelling time 20 s; 150 N, 1.5 Hz in a 37 degrees C water bath), all specimens were subjected to retention force testing using a pull-out test using a universal testing machine and a custom fixture with a crosshead speed 5 mm/min. Modes of failure were classified as Type 1, 2, or 3. Retention force values were analyzed by the t-test for the prepolymerized denture acrylic resin specimen groups, and 1-way ANOVA and the Tukey test for the zirconia groups at alpha = 0.05. ResultsMean and standard deviation retention force values varied from 101.1 +/- 67.1 to 509.0 +/- 65.2 N for the prepolymerized denture acrylic resin specimen groups. The zirconia groups ranged from 572.8 +/- 274.7 to 1416.1 +/- 258.0 N. There is no statistically significant difference in retention force values between V and C specimens cementing to zirconia with Panavia SA cement (Kuraray Noritake) (p = 0.587). The retention forces and failure modes were influenced by the cement used (p < 0.05). Modes of failure were predominantly Type 2 (mixed failure) and Type 1 (adhesive fracture from prosthetic materials) except for the quick-set resin group (Type 3, adhesive failure from coping). ConclusionsWhen bonding IFDPs onto titanium copings, quick-set resin provided significantly higher retention force for prepolymerized denture acrylic resin prostheses. Conical and cylindrical titanium copings performed similarly when cemented to zirconia with Panavia SA cement under the same protocol. The stability of the bonded interface and retention forces between zirconia prostheses and titanium copings varied from the cement used.
引用
收藏
页码:340 / 347
页数:8
相关论文
共 50 条
  • [31] Titanium versus zirconia complete arch implant-supported fixed prostheses: A comparison of plaque accumulation
    Curiel-Aguilera, Francisco P.
    Grif, Garth R.
    Rossmann, Jeffrey A.
    Gonzalez, Jorge A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (03): : 369 - 375
  • [32] Effect of framework material on the color of implant-supported complete-arch fixed dental prostheses
    Yilmaz, Burak
    Alp, Gulce
    Johnston, William M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (01): : 69 - 75
  • [33] Reliability and fatigue failure modes of implant-supported aluminum-oxide fixed dental prostheses
    Stappert, Christian F. J.
    Baldassarri, Marta
    Zhang, Yu
    Haenssler, Felix
    Rekow, Elizabeth D.
    Thompson, Van P.
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (10) : 1173 - 1180
  • [34] Guided implant scanning: A procedure for improving the accuracy of implant-supported complete-arch fixed dental prostheses
    Gomez-Polo, Miguel
    Ballesteros, Juan
    Perales-Padilla, Pedro
    Perales-Pulido, Pedro
    Gomez-Polo, Cristina
    Ortega, Rocio
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 135 - 139
  • [35] Effect of veneering materials on fracture loads of implant-supported zirconia molar fixed dental prostheses
    Kondo, Tomohide
    Komine, Futoshi
    Honda, Junichi
    Takata, Hiroki
    Moriya, Yuta
    JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (02) : 140 - 144
  • [36] Milled PMMA: A Material for Long-Term Implant-Supported Fixed Complete Dental Prostheses
    Kotina, Elli
    Hamilton, Adam
    Lee, Jason D.
    Lee, Sang J.
    Grieco, Peter C.
    Pedrinaci, Ignacio
    Griseto, Neil T.
    Gallucci, German O.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (02) : 225 - 231
  • [37] Peri-Implant Diseases and Biologic Complications at Implant-Supported Fixed Dental Prostheses in Partially Edentulous Patients
    Tsigarida, Alexandra
    Chochlidakis, Konstantinos
    Fraser, David
    Lampraki, Evangelia
    Einarsdottir, Erna R.
    Barmak, Abdul Basir
    Papaspyridakos, Panos
    Ercoli, Carlo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (05): : 429 - 435
  • [38] Stability of Screw-Retained Implant-Supported Fixed Dental Prostheses Bonded to Gold Cylinders
    Karl, Matthias
    Graef, Friedrich
    Taylor, Thomas D.
    Heckmann, Siegfried M.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2009, 22 (06) : 604 - 606
  • [39] New ways of designing suprastructures for fixed implant-supported prostheses
    Salenbauch, NM
    Langner, J
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 1998, 18 (06) : 605 - 612
  • [40] The Impact of Implant Angulation on the Stress Distribution and Survival Rate of Implant-Supported Fixed Dental Prostheses: A Retrospective Study
    Chatterjee, Elashri
    Nasha, Amit
    Mustafa, Mohammed
    Chinthalapudi, Sai Lakshmi
    Padavala, Sushma
    Lakshmipuram, Achyuth Kumar
    Bhatnagar, Tarun K.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)