How to achieve adequate quenching for DBP analysis in drinking water?

被引:9
|
作者
Ren, Jiafeng [1 ]
Tang, Mengmeng [1 ]
Wang, Leyi [1 ]
Chu, Wenhai [2 ]
Shi, Wei [1 ]
Zhou, Qing [1 ]
Pan, Yang [1 ]
机构
[1] Nanjing Univ, Sch Environm, State Key Lab Pollut Control & Resource Reuse, Nanjing 210023, Jiangsu, Peoples R China
[2] Tongji Univ, Coll Environm Sci & Engn, State Key Lab Pollut Control & Resource Reuse, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Quenching; Adequate quenching; Disinfection; Disinfection byproducts; Drinking water; DISINFECTION BY-PRODUCT; HYPOCHLORITE SOLUTIONS; SODIUM THIOSULFATE; CHLORINE; DECOMPOSITION; KINETICS; TETRATHIONATE; TEMPERATURE; PRECURSOR; IMPACT;
D O I
10.1016/j.watres.2024.121264
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Quenching is an important step to terminate disinfection during preparation of disinfected water samples for the analysis of disinfection byproducts (DBPs). However, an incomplete quenching might result in continued reactions of residual chlorine, whereas an excessive quenching might decompose target DBPs. Therefore, an adequate quenching to achieve simultaneous disinfection termination and DBP preservation is of particular importance. In this study, the two -stage reaction kinetics of chlorine and three commonly used quenching agents (i.e., ascorbic acid, sodium thiosulfate, and sodium sulfite) were determined. Stopping quenching during the first stage prevented interactions of residual chlorine with natural organic matter. Complete quenching was achieved by minimizing the quenching time for ascorbic acid and sodium sulfite, while limiting the quenching time to less than 3 min for sodium thiosulfate. At the optimized quenching times, the molar ratios (MRs) of quenching agent to chlorine were 1.05, 1.10, and 0.75 for ascorbic acid, sodium sulfite, and sodium thiosulfate, respectively. The destructive effects of the three quenching agents on total organic halogen (TOX) followed the rank order of ascorbic acid (33.7-64.8 %) < sodium sulfite (41.6-72.8 %) < sodium thiosulfate (43.3-73.2 %), and the destructive effects on aliphatic DBPs also followed the rank order of ascorbic acid (29.5-44.5 %) < sodium sulfite (34.9-51.9 %) < sodium thiosulfate (46.9-53.2 %). For total organic chlorine (TOCl) and aliphatic DBPs, the quenching behavior itself had more significant destructive effect than the quenching agent type/dose and quenching time, but for total organic bromine (TOBr), the destructive effect caused by quenching agent type/ dose and quenching time was more significant. High -dose, long -duration quenching enhanced the reduction of TOX, but had little effect on aliphatic DBPs. Additionally, the three quenching agents reduced the levels of halophenols (except for tribromophenol), while maintained or increased the levels of tribromophenol, halobenzoic/salicylic acids, and halobenzaldehydes/salicylaldehydes. To achieve adequate quenching for overall DBP analysis in chlorinated water samples, it is recommended to use ascorbic acid at a quenching agent -tochlorine MR of 1.0 for a quenching time of < 0.5 h.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Examining the interrelationship between DOC, bromide and chlorine dose on DBP formation in drinking water - A case study
    Bond, Tom
    Huang, Jin
    Graham, Nigel J. D.
    Templeton, Michael R.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 470 : 469 - 479
  • [32] Volatile DBPs contributed marginally to the developmental toxicity of drinking water DBP mixtures against Platynereis dumerilii
    Li, Yu
    Jiang, Jingyi
    Li, Wanxin
    Zhu, Xiaohu
    Zhang, Xiangru
    Jiang, Feng
    CHEMOSPHERE, 2020, 252
  • [33] TRIHALOMETHANES ANALYSIS IN DRINKING WATER
    Culea, M.
    Iordache, A.
    Cozar, O.
    Ristoiu, D.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2009, 10 (02): : 342 - 350
  • [34] Neural network-based modelling of the adequate chlorine dosage for drinking water disinfection
    Rodriguez, MJ
    Serodes, JB
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1996, 23 (03) : 621 - 631
  • [35] WATER REUSE, SAFE DRINKING ACT - HOW SOON, HOW GOOD
    HECKROTH, CW
    WATER & WASTES ENGINEERING, 1974, 11 (08): : 30 - &
  • [36] Quenching of chlorination disinfection by-product formation in drinking water by hydrogen peroxide
    Batterman, S
    Zhang, LZ
    Wang, SQ
    WATER RESEARCH, 2000, 34 (05) : 1652 - 1658
  • [37] Control of aliphatic halogenated DBP precursors with multiple drinking water treatment processes: Formation potential and integrated toxicity
    Yimeng Zhang
    Wenhai Chu
    Dechang Yao
    Daqiang Yin
    Journal of Environmental Sciences, 2017, 58 (08) : 322 - 330
  • [38] Arsenic in drinking water - How much is too much?
    Sullivan, C
    CHEMICAL ENGINEERING PROGRESS, 2001, 97 (05) : 14 - 14
  • [39] Arsenic in drinking water: How much is too much?
    Cantor, KP
    EPIDEMIOLOGY, 1996, 7 (02) : 113 - 115
  • [40] DRINKING-WATER RESEARCH - HOW ARE WE DOING
    MILLER, WH
    MANNION, JB
    SINGLEY, JE
    MCGUIRE, MJ
    KUHN, W
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1985, 77 (01): : 22 - &