How to achieve adequate quenching for DBP analysis in drinking water?

被引:9
|
作者
Ren, Jiafeng [1 ]
Tang, Mengmeng [1 ]
Wang, Leyi [1 ]
Chu, Wenhai [2 ]
Shi, Wei [1 ]
Zhou, Qing [1 ]
Pan, Yang [1 ]
机构
[1] Nanjing Univ, Sch Environm, State Key Lab Pollut Control & Resource Reuse, Nanjing 210023, Jiangsu, Peoples R China
[2] Tongji Univ, Coll Environm Sci & Engn, State Key Lab Pollut Control & Resource Reuse, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Quenching; Adequate quenching; Disinfection; Disinfection byproducts; Drinking water; DISINFECTION BY-PRODUCT; HYPOCHLORITE SOLUTIONS; SODIUM THIOSULFATE; CHLORINE; DECOMPOSITION; KINETICS; TETRATHIONATE; TEMPERATURE; PRECURSOR; IMPACT;
D O I
10.1016/j.watres.2024.121264
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Quenching is an important step to terminate disinfection during preparation of disinfected water samples for the analysis of disinfection byproducts (DBPs). However, an incomplete quenching might result in continued reactions of residual chlorine, whereas an excessive quenching might decompose target DBPs. Therefore, an adequate quenching to achieve simultaneous disinfection termination and DBP preservation is of particular importance. In this study, the two -stage reaction kinetics of chlorine and three commonly used quenching agents (i.e., ascorbic acid, sodium thiosulfate, and sodium sulfite) were determined. Stopping quenching during the first stage prevented interactions of residual chlorine with natural organic matter. Complete quenching was achieved by minimizing the quenching time for ascorbic acid and sodium sulfite, while limiting the quenching time to less than 3 min for sodium thiosulfate. At the optimized quenching times, the molar ratios (MRs) of quenching agent to chlorine were 1.05, 1.10, and 0.75 for ascorbic acid, sodium sulfite, and sodium thiosulfate, respectively. The destructive effects of the three quenching agents on total organic halogen (TOX) followed the rank order of ascorbic acid (33.7-64.8 %) < sodium sulfite (41.6-72.8 %) < sodium thiosulfate (43.3-73.2 %), and the destructive effects on aliphatic DBPs also followed the rank order of ascorbic acid (29.5-44.5 %) < sodium sulfite (34.9-51.9 %) < sodium thiosulfate (46.9-53.2 %). For total organic chlorine (TOCl) and aliphatic DBPs, the quenching behavior itself had more significant destructive effect than the quenching agent type/dose and quenching time, but for total organic bromine (TOBr), the destructive effect caused by quenching agent type/ dose and quenching time was more significant. High -dose, long -duration quenching enhanced the reduction of TOX, but had little effect on aliphatic DBPs. Additionally, the three quenching agents reduced the levels of halophenols (except for tribromophenol), while maintained or increased the levels of tribromophenol, halobenzoic/salicylic acids, and halobenzaldehydes/salicylaldehydes. To achieve adequate quenching for overall DBP analysis in chlorinated water samples, it is recommended to use ascorbic acid at a quenching agent -tochlorine MR of 1.0 for a quenching time of < 0.5 h.
引用
收藏
页数:12
相关论文
共 50 条
  • [11] Online THM monitoring helps New Jersey water authority achieve DBP compliance
    Old Bridge Municipal Utilities Authority, United States
    不详
    Water Wastes Dig, 3 (12-13):
  • [12] Antibiotic treatments via drinking water in sheep fattening houses: how to ensure an adequate exposure of the treated population?
    Roques, B. B.
    Lacroix, M. Z.
    Fouzari, L.
    Ferran, A. A.
    Concordet, D.
    Bousquet-Melou, A.
    JOURNAL OF VETERINARY PHARMACOLOGY AND THERAPEUTICS, 2018, 41 : 25 - 26
  • [13] Effects of Iron Particles on Chlorine Decay and DBP Removal during Boiling Drinking Water
    Li, Penglu
    Zhuang, Yuan
    Zhang, Yao
    Shi, Baoyou
    ACS ES&T WATER, 2023, 3 (12): : 3961 - 3966
  • [14] How safe is our drinking water?
    Rao, Vikram, 1600, Society of Petroleum Engineers (SPE) (66):
  • [15] CLEAN WATER - WHAT IS IT - HOW WILL WE ACHIEVE IT
    GUSHEE, DE
    CHEMTECH, 1973, (JUN) : 334 - 344
  • [16] Water justice: why it matters and how to achieve it
    Sultana, Farhana
    WATER INTERNATIONAL, 2018, 43 (04) : 483 - 493
  • [17] Analysis of Water Used for Haemodialysis in Dialysis Centres, South East Nigeria: How Adequate?
    Nwobodo, U.
    Arodiwe, E.
    Ijoma, C.
    Ulasi, I
    WEST INDIAN MEDICAL JOURNAL, 2022, 69 (08): : 578 - 584
  • [18] The dependence of chlorine decay and DBP formation kinetics on pipe flow properties in drinking water distribution
    Zhao, Yingying
    Yang, Y. Jeffrey
    Shao, Yu
    Neal, Jill
    Zhang, Tuqiao
    WATER RESEARCH, 2018, 141 : 32 - 45
  • [19] Mineral accounting: the way to combat eutrophication and to achieve the drinking water objective
    van den Brandt, HMP
    Smit, HP
    NITROGEN, THE CONFER-N-S, 1998, : 705 - 709
  • [20] Mineral accounting: the way to combat eutrophication and to achieve the drinking water objective
    van den Brandt, HMP
    Smit, HP
    ENVIRONMENTAL POLLUTION, 1998, 102 : 705 - 709