Improvement in Intraoperative Image Quality in Transcranial Magnetic Resonance-Guided Focused Ultrasound Surgery Using Transmitter Gain Adjustment

被引:0
|
作者
Hori, Hiroki [1 ]
Yamada, Yusuke [2 ]
Nakano, Masayuki [3 ]
Ouchi, Takahiro [4 ]
Takasaki, Masahito [5 ]
Iijima, Ken [6 ]
Taira, Takaomi [7 ]
Abe, Keiichi [7 ]
Iwamuro, Hirokazu [8 ]
机构
[1] Moriyama Neurosurg Ctr Hosp, Dept FUS Ctr, Tokyo, Japan
[2] Hokkaido Ohno Mem Hosp, Dept Radiol, Sapporo, Japan
[3] Shin Yurigaoka Gen Hosp, Dept Neurosurg, Kawasaki, Japan
[4] Shin Yurigaoka Gen Hosp, Dept Neurol, Kawasaki, Japan
[5] Shin Yurigaoka Gen Hosp, Dept Anesthesiol, Kawasaki, Japan
[6] Saitama Sekishinkai Hosp, Dept Diagnost Radiol, Saitama, Japan
[7] Tokyo Womens Med Univ, Dept Neurosurg, Tokyo, Japan
[8] Juntendo Univ, Dept Neurosurg, Tokyo, Japan
关键词
Essential tremor; Flip angle; magnetic resonance imaging; Stereotactic thalamotomy; Transcranial magnetic resonance-guided focused ultrasound surgery; Transmitter gain; TO-NOISE RATIOS; B-1; INHOMOGENEITY; PULSE; MRI; THALAMOTOMY; TREMOR;
D O I
10.1159/000531009
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction: Transcranial magnetic resonance-guided focused ultrasound surgery (TcMRgFUS) has the advantage of allowing immediate evaluation of therapeutic effects after each sonication and intraoperative magnetic resonance imaging (MRI) to visualize the lesion. When the image shows that the lesion has missed the planned target and the therapeutic effects are insufficient, the target of the subsequent ablation can be finely adjusted based on the image. The precision of this adjustment is determined by the image quality. However, the current intraoperative image quality with a 3.0T MRI system is insufficient for precisely detecting the lesion. Thus, we developed and validated a method for improving intraoperative image quality. Methods: Because intraoperative image quality is affected by transmitter gain (TG), we acquired T2-weighted images (T2WIs) with two types of TG: the automatically adjusted TG (auto TG) and the manually adjusted TG (manual TG). To evaluate the character of images with 2 TGs, the actual flip angle (FA), the image uniformity, and the signal-to-noise ratio (SNR) were measured using a phantom. Then, to assess the quality of intraoperative images, T2WIs with both TGs were acquired during TcMRgFUS for 5 patients. The contrast-to-noise ratio (CNR) of the lesion was retrospectively estimated. Results: The images of the phantom with the auto TG showed substantial variations between the preset and actual FAs (p < 0.01), whereas on the images with the manual TG, there were no variations between the two FAs (p > 0.05). The total image uniformity was considerably lower with the manual TG than with the auto TG (p < 0.01), indicating that the image's signal values with the manual TG were more uniform. The manual TG produced significantly higher SNRs than the auto TG (p < 0.01). In the clinical study, the lesions were clearly detected in intraoperative images with the manual TG, but they were difficult to identify in images with the auto TG. The CNR of lesions in images with manual TG was considerably higher than in images with auto TG (p < 0.01). Conclusion: Regarding intraoperative T2WIs using a 3.0T MRI system during TcMRgFUS, the manual TG method improved image quality and delineated the ablative lesion more clearly than the current method with auto TG.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 50 条
  • [41] Safety and Efficacy of Magnetic Resonance-Guided Focused Ultrasound Surgery With Autofocusing Echo Imaging
    Chang, Kyung Won
    Rachmilevitch, Itay
    Chang, Won Seok
    Jung, Hyun Ho
    Zadicario, Eyal
    Prus, Oleg
    Chang, Jin Woo
    FRONTIERS IN NEUROSCIENCE, 2021, 14
  • [42] Efficacy of Magnetic Resonance-guided Focused Ultrasound Surgery for Bone Metastases Pain Palliation
    Kawasaki, Motohiro
    Nanba, Hirofumi
    Kato, Tomonari
    Tani, Toshikazu
    Ushida, Takahiro
    10TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND (ISTU 2010), 2011, 1359 : 488 - +
  • [43] Magnetic resonance-guided focused ultrasound surgery for leiomyoma and adenomyosis: An alternative nonvascular approach
    Minh Duc Nguyen
    GYNECOLOGY AND MINIMALLY INVASIVE THERAPY-GMIT, 2019, 8 (04): : 196 - 198
  • [44] Treatment of Major Depressive Disorder via Magnetic Resonance-Guided Focused Ultrasound Surgery
    Kim, Minsoo
    Kim, Chan-Hyung
    Jung, Hyun Ho
    Kim, Se Joo
    Chang, Jin Woo
    BIOLOGICAL PSYCHIATRY, 2018, 83 (01) : E17 - E18
  • [45] Magnetic resonance-guided focused ultrasound and essential tremor Response
    Mohammed, Nasser
    Patra, Devi
    Nanda, Anil
    NEUROSURGICAL FOCUS, 2018, 45 (01)
  • [46] Magnetic Resonance-Guided Focused Ultrasound without Anesthesiologist Support
    Mueller, Julia
    Chiu, Lucinda
    Lynn, Fiona
    Lewis, Rachel
    Patel, Shama
    Wodziak, Matthew
    Patel, Neepa
    Sani, Sepehr
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2024, 102 (03) : 169 - 178
  • [47] Magnetic Resonance-Guided Focused Ultrasound Capsulotomy for Musical Obsessions
    Davidson, Benjamin
    Hamani, Clement
    Rabin, Jennifer S.
    Meng, Ying
    Richter, Margaret Anne
    Giacobbe, Peter
    Lipsman, Nir
    BIOLOGICAL PSYCHIATRY, 2021, 90 (10) : E49 - E50
  • [48] Update on Clinical Magnetic Resonance-Guided Focused Ultrasound Applications
    Kobus, Thiele
    McDannold, Nathan
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2015, 23 (04) : 657 - +
  • [49] Update on musculoskeletal applications of magnetic resonance-guided focused ultrasound
    McGill, Kevin C.
    Baal, Joe D.
    Bucknor, Matthew D.
    SKELETAL RADIOLOGY, 2024, 53 (08) : 1507 - 1515
  • [50] Magnetic resonance-guided focused ultrasound in dystonia: a scoping review
    Guinal, Safrollah M.
    Jamora, Roland Dominic G.
    Khu, Kathleen Joy O.
    Aguilar, Jose A.
    NEUROLOGICAL SCIENCES, 2025, 46 (03) : 1121 - 1130