Improvement in Intraoperative Image Quality in Transcranial Magnetic Resonance-Guided Focused Ultrasound Surgery Using Transmitter Gain Adjustment

被引:0
|
作者
Hori, Hiroki [1 ]
Yamada, Yusuke [2 ]
Nakano, Masayuki [3 ]
Ouchi, Takahiro [4 ]
Takasaki, Masahito [5 ]
Iijima, Ken [6 ]
Taira, Takaomi [7 ]
Abe, Keiichi [7 ]
Iwamuro, Hirokazu [8 ]
机构
[1] Moriyama Neurosurg Ctr Hosp, Dept FUS Ctr, Tokyo, Japan
[2] Hokkaido Ohno Mem Hosp, Dept Radiol, Sapporo, Japan
[3] Shin Yurigaoka Gen Hosp, Dept Neurosurg, Kawasaki, Japan
[4] Shin Yurigaoka Gen Hosp, Dept Neurol, Kawasaki, Japan
[5] Shin Yurigaoka Gen Hosp, Dept Anesthesiol, Kawasaki, Japan
[6] Saitama Sekishinkai Hosp, Dept Diagnost Radiol, Saitama, Japan
[7] Tokyo Womens Med Univ, Dept Neurosurg, Tokyo, Japan
[8] Juntendo Univ, Dept Neurosurg, Tokyo, Japan
关键词
Essential tremor; Flip angle; magnetic resonance imaging; Stereotactic thalamotomy; Transcranial magnetic resonance-guided focused ultrasound surgery; Transmitter gain; TO-NOISE RATIOS; B-1; INHOMOGENEITY; PULSE; MRI; THALAMOTOMY; TREMOR;
D O I
10.1159/000531009
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction: Transcranial magnetic resonance-guided focused ultrasound surgery (TcMRgFUS) has the advantage of allowing immediate evaluation of therapeutic effects after each sonication and intraoperative magnetic resonance imaging (MRI) to visualize the lesion. When the image shows that the lesion has missed the planned target and the therapeutic effects are insufficient, the target of the subsequent ablation can be finely adjusted based on the image. The precision of this adjustment is determined by the image quality. However, the current intraoperative image quality with a 3.0T MRI system is insufficient for precisely detecting the lesion. Thus, we developed and validated a method for improving intraoperative image quality. Methods: Because intraoperative image quality is affected by transmitter gain (TG), we acquired T2-weighted images (T2WIs) with two types of TG: the automatically adjusted TG (auto TG) and the manually adjusted TG (manual TG). To evaluate the character of images with 2 TGs, the actual flip angle (FA), the image uniformity, and the signal-to-noise ratio (SNR) were measured using a phantom. Then, to assess the quality of intraoperative images, T2WIs with both TGs were acquired during TcMRgFUS for 5 patients. The contrast-to-noise ratio (CNR) of the lesion was retrospectively estimated. Results: The images of the phantom with the auto TG showed substantial variations between the preset and actual FAs (p < 0.01), whereas on the images with the manual TG, there were no variations between the two FAs (p > 0.05). The total image uniformity was considerably lower with the manual TG than with the auto TG (p < 0.01), indicating that the image's signal values with the manual TG were more uniform. The manual TG produced significantly higher SNRs than the auto TG (p < 0.01). In the clinical study, the lesions were clearly detected in intraoperative images with the manual TG, but they were difficult to identify in images with the auto TG. The CNR of lesions in images with manual TG was considerably higher than in images with auto TG (p < 0.01). Conclusion: Regarding intraoperative T2WIs using a 3.0T MRI system during TcMRgFUS, the manual TG method improved image quality and delineated the ablative lesion more clearly than the current method with auto TG.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 50 条
  • [21] Magnetic resonance-guided focused ultrasound and essential tremor
    Gallay, Marc
    Jeanmonod, Daniel
    NEUROSURGICAL FOCUS, 2018, 45 (01)
  • [22] Intracranial Applications of Magnetic Resonance-guided Focused Ultrasound
    Nir Lipsman
    Todd G. Mainprize
    Michael L. Schwartz
    Kullervo Hynynen
    Andres M. Lozano
    Neurotherapeutics, 2014, 11 : 593 - 605
  • [23] Comparative Evaluation of Magnetic Resonance-Guided Focused Ultrasound Surgery for Essential Tremor
    Kim, Minsoo
    Jung, Na Young
    Park, Chang Kyu
    Chang, Won Seok
    Jung, Hyun Ho
    Chang, Jin Woo
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2017, 95 (04) : 279 - 286
  • [24] Magnetic resonance-guided focused ultrasound for the treatment of tremor
    Yamamoto, Kazuaki
    Sarica, Can
    Loh, Aaron
    Vetkas, Artur
    Samuel, Nardin
    Milano, Vanessa
    Zemmar, Ajmal
    Germann, Juergen
    Cheyuo, Cletus
    Boutet, Alexandre
    Elias, Gavin J. B.
    Ito, Hisashi
    Taira, Takaomi
    Lozano, Andres M.
    EXPERT REVIEW OF NEUROTHERAPEUTICS, 2022, 22 (10) : 849 - 861
  • [25] Musculoskeletal Applications of Magnetic Resonance-Guided Focused Ultrasound
    Bucknor, Matthew D.
    Baal, Joe D.
    McGill, Kevin C.
    Infosino, Andrew
    Link, Thomas M.
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2021, 25 (06) : 725 - 734
  • [26] Magnetic resonance-guided focused ultrasound surgery for leiomyoma-associated infertility
    Bouwsma, Esther V. A.
    Gorny, Krzysztof R.
    Hesley, Gina K.
    Jensen, Jani R.
    Peterson, Lisa G.
    Stewart, Elizabeth A.
    FERTILITY AND STERILITY, 2011, 96 (01) : E9 - E12
  • [27] Magnetic resonance-guided focused ultrasound surgery for treatment of painful osseous metastases
    Hurwitz, Mark
    Machtinger, Ronit
    Fennessy, Fiona
    ENERGY-BASED TREATMENT OF TISSUE AND ASSESSMENT VI, 2011, 7901
  • [28] Magnetic resonance-guided focused ultrasound surgery of breast cancer: Reliability and effectiveness
    Furusawa, H
    Namba, K
    Thomsen, S
    Akiyama, F
    Bendet, A
    Tanaka, C
    Yasuda, Y
    Nakahara, H
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2006, 203 (01) : 54 - 63
  • [29] Subjective effect of magnetic resonance-guided focused ultrasound surgery for uterine fibroids
    Funaki, Kaoru
    Sawada, Katsuhiro
    Maeda, Fumio
    Nagai, Syuji
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2007, 33 (06) : 834 - 839
  • [30] Magnetic resonance-guided focused ultrasound for uterine fibroids
    Magalha, Pedro Felipe
    Messina, Marcos de Lorenzo
    Soares Junior, Jose Maria
    Baracat, Edmund Chada
    CLINICS, 2025, 80