Improvement in Intraoperative Image Quality in Transcranial Magnetic Resonance-Guided Focused Ultrasound Surgery Using Transmitter Gain Adjustment

被引:0
|
作者
Hori, Hiroki [1 ]
Yamada, Yusuke [2 ]
Nakano, Masayuki [3 ]
Ouchi, Takahiro [4 ]
Takasaki, Masahito [5 ]
Iijima, Ken [6 ]
Taira, Takaomi [7 ]
Abe, Keiichi [7 ]
Iwamuro, Hirokazu [8 ]
机构
[1] Moriyama Neurosurg Ctr Hosp, Dept FUS Ctr, Tokyo, Japan
[2] Hokkaido Ohno Mem Hosp, Dept Radiol, Sapporo, Japan
[3] Shin Yurigaoka Gen Hosp, Dept Neurosurg, Kawasaki, Japan
[4] Shin Yurigaoka Gen Hosp, Dept Neurol, Kawasaki, Japan
[5] Shin Yurigaoka Gen Hosp, Dept Anesthesiol, Kawasaki, Japan
[6] Saitama Sekishinkai Hosp, Dept Diagnost Radiol, Saitama, Japan
[7] Tokyo Womens Med Univ, Dept Neurosurg, Tokyo, Japan
[8] Juntendo Univ, Dept Neurosurg, Tokyo, Japan
关键词
Essential tremor; Flip angle; magnetic resonance imaging; Stereotactic thalamotomy; Transcranial magnetic resonance-guided focused ultrasound surgery; Transmitter gain; TO-NOISE RATIOS; B-1; INHOMOGENEITY; PULSE; MRI; THALAMOTOMY; TREMOR;
D O I
10.1159/000531009
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction: Transcranial magnetic resonance-guided focused ultrasound surgery (TcMRgFUS) has the advantage of allowing immediate evaluation of therapeutic effects after each sonication and intraoperative magnetic resonance imaging (MRI) to visualize the lesion. When the image shows that the lesion has missed the planned target and the therapeutic effects are insufficient, the target of the subsequent ablation can be finely adjusted based on the image. The precision of this adjustment is determined by the image quality. However, the current intraoperative image quality with a 3.0T MRI system is insufficient for precisely detecting the lesion. Thus, we developed and validated a method for improving intraoperative image quality. Methods: Because intraoperative image quality is affected by transmitter gain (TG), we acquired T2-weighted images (T2WIs) with two types of TG: the automatically adjusted TG (auto TG) and the manually adjusted TG (manual TG). To evaluate the character of images with 2 TGs, the actual flip angle (FA), the image uniformity, and the signal-to-noise ratio (SNR) were measured using a phantom. Then, to assess the quality of intraoperative images, T2WIs with both TGs were acquired during TcMRgFUS for 5 patients. The contrast-to-noise ratio (CNR) of the lesion was retrospectively estimated. Results: The images of the phantom with the auto TG showed substantial variations between the preset and actual FAs (p < 0.01), whereas on the images with the manual TG, there were no variations between the two FAs (p > 0.05). The total image uniformity was considerably lower with the manual TG than with the auto TG (p < 0.01), indicating that the image's signal values with the manual TG were more uniform. The manual TG produced significantly higher SNRs than the auto TG (p < 0.01). In the clinical study, the lesions were clearly detected in intraoperative images with the manual TG, but they were difficult to identify in images with the auto TG. The CNR of lesions in images with manual TG was considerably higher than in images with auto TG (p < 0.01). Conclusion: Regarding intraoperative T2WIs using a 3.0T MRI system during TcMRgFUS, the manual TG method improved image quality and delineated the ablative lesion more clearly than the current method with auto TG.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 50 条
  • [1] Magnetic Resonance-Guided Focused Ultrasound Surgery
    Al Hilli, Mariam M.
    Stewart, Elizabeth A.
    SEMINARS IN REPRODUCTIVE MEDICINE, 2010, 28 (03) : 241 - 248
  • [2] Magnetic resonance-guided focused ultrasound surgery
    Hudson, Susan B. A.
    Stewart, Elizabeth A.
    CLINICAL OBSTETRICS AND GYNECOLOGY, 2008, 51 (01): : 159 - 166
  • [3] Magnetic resonance-guided focused ultrasound surgery RESPONSE
    Elias, W. Jeffrey
    Monteith, Stephen J.
    JOURNAL OF NEUROSURGERY, 2013, 119 (02) : 531 - 531
  • [4] Acoustic Coupling Bath Using Heavy Water For Transcranial Magnetic Resonance-Guided Focused Ultrasound Surgery
    Ma, Xiao
    Shen, Guofeng
    Zong, Shenyan
    Gu, Jiawei
    Wu, Hao
    Zhang, Shengfa
    Wei, Bo
    2021 14TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2021), 2021,
  • [5] Consensus for clinical applications of transcranial magnetic resonance-guided focused ultrasound
    Pan, Longsheng
    Xiong, Yongqin
    Li, Yongjie
    Sun, Bomin
    Li, Xuemei
    Zhou, Shouguo
    Lou, Xin
    CHINESE MEDICAL JOURNAL, 2024, 137 (22) : 2684 - 2686
  • [6] Consensus for clinical applications of transcranial magnetic resonance-guided focused ultrasound
    Pan Longsheng
    Xiong Yongqin
    Li Yongjie
    Sun Bomin
    Li Xuemei
    Zhou Shouguo
    Lou Xin
    中华医学杂志英文版, 2024, 137 (22)
  • [7] Magnetic resonance-guided focused ultrasound
    Albuquerque, Felipe C.
    NEUROSURGICAL FOCUS, 2013, 34 (05)
  • [8] Transcranial magnetic resonance-guided focused ultrasound surgery at 1.5T: a technical note
    Gagliardo, Cesare
    Midiri, Massimo
    Cannella, Roberto
    Napoli, Alessandro
    Wragg, Paul
    Collura, Giorgio
    Marrale, Maurizio
    Bartolotta, Tommaso Vincenzo
    Catalano, Carlo
    Lagalla, Roberto
    NEURORADIOLOGY JOURNAL, 2019, 32 (02): : 132 - 138
  • [9] Improving image quality in transcranial magnetic resonance guided focused ultrasound using a conductive screen
    Hadley, J. R.
    Odeen, H.
    Merrill, R.
    Adams, S., I
    Rieke, V
    Payne, A.
    Parker, D. L.
    MAGNETIC RESONANCE IMAGING, 2021, 83 : 41 - 49
  • [10] Metabolic changes following transcranial magnetic resonance-guided focused ultrasound subthalamotomy
    Rodriguez-Rojas, R.
    Martinez-Fernandez, R.
    Pineda-Pardo, J.
    Sanchez-Catasus, C.
    Del Alamo, M.
    Obeso, J.
    MOVEMENT DISORDERS, 2017, 32 (12) : E17 - E17