Spatial awareness application using mixed reality for 3D X-ray CT examination

被引:4
|
作者
Kase, H. [1 ,2 ]
Nishizawa, J. [1 ]
Tabata, K. [2 ]
Takagi, K. [2 ]
Aoki, T. [1 ,2 ]
机构
[1] Shizuoka Univ, Grad Sch Med Photon, 3-5-1 Johoku Naka Ku, Hamamatsu, Shizuoka, Japan
[2] Shizuoka Univ, Res Inst Elect, 3-5-1 Johoku Naka Ku, Hamamatsu, Shizuoka, Japan
关键词
Computerized Tomography (CT) and Computed Radiography (CR); Image processing; Inspection with x-rays;
D O I
10.1088/1748-0221/18/03/P03032
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the medical field, X-ray computed tomography (CT) is used to determine the size of defects and damage in an examined object, and to diagnose infectious diseases. Generally, data captured by 3D X-ray CT are viewed as images in three directions (sagittal, axial, and coronal) on a computer. However, augmented reality, virtual reality, and mixed reality are emerging as alternatives for imaging captured data for 3D X-ray CT and are used for medical simulations and educational purposes. Although these techniques are capable of 3D expression, they are limited to the representation of the surface structure of the object. The original function required of these technologies is to check the tomographic image of a specific part of the object by specifying any direction and position in three dimensions. This study proposes a method of representation in which a 2D digital imaging communication image is superimposed on a surface-rendered cross-section of an object. In addition, it proposes a pointing system using motion capture and a spatial reality display. The observer can confirm the object from any direction and understand the structure spatially. It can be moved and rotated with movements similar to actually holding, grabbing, moving, and rotating with hands. Moreover, the cross-section can be observed in any direction. In addition, by matching the respective scales of the device and application, the object can be represented with an error of less than 1 mm in the horizontal, vertical, and depth directions with respect to the actual object. Therefore, the proposed method is an effective 3D representation method in 3D X-rays, which are voxel data containing internal information. Furthermore, this method can easily indicate the desired location where the cross-section image can be viewed in a CT image. This study will help improve the efficiency of 3D X-ray inspection and surgery in the medical field.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] X-ray holography: Atoms in 3D
    Tegze, M
    Faigel, G
    Bortel, G
    Marchesini, S
    Belakhovsky, M
    Simionovici, A
    JOURNAL OF ALLOYS AND COMPOUNDS, 2005, 401 (1-2) : 92 - 98
  • [42] Multiscale 3D X-ray imaging
    Kline, R. Joseph
    NATURE ELECTRONICS, 2019, 2 (10) : 435 - 436
  • [43] Dedicated Breast CT: Numerical Evaluation of Improvement in X-Ray Fluence Uniformity Using 3D Beam-Shaping X-Ray Filter
    Vedantham, S.
    Karellas, A.
    MEDICAL PHYSICS, 2017, 44 (06) : 3177 - 3177
  • [44] 3D imaging of sugarcane bagasse using X-ray microtomography
    Isaac, A.
    Sket, F.
    Driemeier, C.
    Rocha, G. J. M.
    INDUSTRIAL CROPS AND PRODUCTS, 2013, 49 : 790 - 793
  • [45] Registration of 3D Transesophageal Echocardiography and X-Ray Fluoroscopy Using An Inverse Geometry X-Ray System
    Speidel, M.
    Hatt, C.
    Tomkowiak, M.
    Funk, T.
    Raval, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 471 - 471
  • [46] 3D Femur Reconstruction Using X-Ray Stereo Pairs
    Akkoul, Sonia
    Hafiane, Adel
    Lespessailles, Eric
    Jennane, Rachid
    IMAGE ANALYSIS AND PROCESSING (ICIAP 2013), PT II, 2013, 8157 : 91 - 100
  • [47] What's inside my USB drive? - X-Ray Microscopy and X-Ray nano CT for 3d packaging
    Oppermann, Martin
    Roth, Holger
    Neubrand, Tobias
    Zerna, Thomas
    PROCEEDINGS OF THE 2013 IEEE 15TH ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE (EPTC 2013), 2013, : 88 - 92
  • [48] Quantitative 3D petrography using X-ray tomography: Application to Bishop Tuff pumice clasts
    Gualda, Guilherme A. R.
    Rivers, Mark
    JOURNAL OF VOLCANOLOGY AND GEOTHERMAL RESEARCH, 2006, 154 (1-2) : 48 - 62
  • [49] High spatial resolution 3D X-ray cone-beam microtomography
    Engelke, K
    Karolczak, M
    Lutz, A
    Seibert, U
    Schaller, S
    Kalender, WA
    RADIOLOGY, 1999, 213P : 194 - 194
  • [50] 3D X-RAY CT IMAGING OF THE BONE LACUNO-CANALICULAR NETWORK
    Peyrin, Francoise
    Pacureanu, Alexandra
    Zuluaga, Maria Alejandra
    Dong, Pei
    Langer, Max
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 1788 - 1791