Spatial awareness application using mixed reality for 3D X-ray CT examination

被引:4
|
作者
Kase, H. [1 ,2 ]
Nishizawa, J. [1 ]
Tabata, K. [2 ]
Takagi, K. [2 ]
Aoki, T. [1 ,2 ]
机构
[1] Shizuoka Univ, Grad Sch Med Photon, 3-5-1 Johoku Naka Ku, Hamamatsu, Shizuoka, Japan
[2] Shizuoka Univ, Res Inst Elect, 3-5-1 Johoku Naka Ku, Hamamatsu, Shizuoka, Japan
关键词
Computerized Tomography (CT) and Computed Radiography (CR); Image processing; Inspection with x-rays;
D O I
10.1088/1748-0221/18/03/P03032
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the medical field, X-ray computed tomography (CT) is used to determine the size of defects and damage in an examined object, and to diagnose infectious diseases. Generally, data captured by 3D X-ray CT are viewed as images in three directions (sagittal, axial, and coronal) on a computer. However, augmented reality, virtual reality, and mixed reality are emerging as alternatives for imaging captured data for 3D X-ray CT and are used for medical simulations and educational purposes. Although these techniques are capable of 3D expression, they are limited to the representation of the surface structure of the object. The original function required of these technologies is to check the tomographic image of a specific part of the object by specifying any direction and position in three dimensions. This study proposes a method of representation in which a 2D digital imaging communication image is superimposed on a surface-rendered cross-section of an object. In addition, it proposes a pointing system using motion capture and a spatial reality display. The observer can confirm the object from any direction and understand the structure spatially. It can be moved and rotated with movements similar to actually holding, grabbing, moving, and rotating with hands. Moreover, the cross-section can be observed in any direction. In addition, by matching the respective scales of the device and application, the object can be represented with an error of less than 1 mm in the horizontal, vertical, and depth directions with respect to the actual object. Therefore, the proposed method is an effective 3D representation method in 3D X-rays, which are voxel data containing internal information. Furthermore, this method can easily indicate the desired location where the cross-section image can be viewed in a CT image. This study will help improve the efficiency of 3D X-ray inspection and surgery in the medical field.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] A new software collection for 3D processing of X-ray CT images
    Chauhan, S.
    Ruehaak, W.
    Sass, I
    Anbergen, H.
    Kabdenov, A.
    Freise, M.
    Wille, T.
    ENERGY GEOTECHNICS, 2016, : 471 - 476
  • [22] Comparison of pelvic incidence measurement using lateral x-ray, standard ct versus ct with 3d reconstruction
    Lee, Carol M.
    Liu, Raymond W.
    EUROPEAN SPINE JOURNAL, 2022, 31 (02) : 241 - 247
  • [23] Comparison of pelvic incidence measurement using lateral x-ray, standard ct versus ct with 3d reconstruction
    Carol M. Lee
    Raymond W. Liu
    European Spine Journal, 2022, 31 : 241 - 247
  • [24] Assessment of perfusion bioreactors system using X-ray μCT technology and 3D modeling methods
    Lovecchio, J.
    Jonsdottir-Buch, S.
    Einarsdottir, G. K.
    Orlygsson, G.
    Sigurjonsson, O. E.
    Gargiulo, P.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2014, 8 : 218 - 218
  • [25] 3D Morphological Measurements of Dental Casts with Occlusal Relationship using Microfocus X-ray CT
    Kamegawa, Masayuki
    Nakamura, Masayuki
    Tsutsumi, Sadami
    DENTAL MATERIALS JOURNAL, 2008, 27 (04) : 549 - 554
  • [26] Recognition of lung nodules from X-ray CT images using 3D MRF models
    Takizawa, H
    Yamamoto, S
    Matsumoto, T
    Tateno, Y
    Iinuma, T
    Matsumoto, M
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 570 - 575
  • [27] Smoothing lung segmentation surfaces in 3D x-ray CT images using anatomic guidance
    Ukil, S
    Reinhardt, JA
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 1066 - 1075
  • [28] 3D experimental investigation of the microstructure of cement pastes using synchrotron X-ray microtomography (μCT)
    Gallucci, E.
    Scrivener, K.
    Groso, A.
    Stampanoni, M.
    Margaritondo, G.
    CEMENT AND CONCRETE RESEARCH, 2007, 37 (03) : 360 - 368
  • [29] PRECISE 3D DIMENSIONAL METROLOGY USING HIGH RESOLUTION X-RAY COMPUTED TOMOGRAPHY (μCT)
    Brunke, Oliver
    Santillan, Javier
    Suppes, Alexander
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804
  • [30] Depiction of pelvic fractures using 3D volumetric holography: Comparison of plain X-ray and CT
    Robertson, D.D., 1600, Lippincott Williams and Wilkins (19):