Voltammetric analysis of mephenoxalone drug in pharmaceutical and biological samples using novel screen-printed sensor with boron-doped diamond electrode

被引:6
|
作者
Matvieiev, Oleksandr [1 ]
Selesovska, Renata [1 ]
Sokolova, Romana [2 ]
Jerga, Radek [3 ]
Skopalova, Jana [1 ,3 ]
Bartak, Petr [3 ]
Chylkova, Jaromira [1 ]
Vojs, Marian [4 ]
机构
[1] Univ Pardubice, Inst Environm & Chem Engn, Fac Chem Technol, Studentska 573, Pardubice 53210, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 3, Prague 18223, Czech Republic
[3] Palacky Univ, Fac Sci, Dept Analyt Chem, 17 listopadu 1192-12, Olomouc 77900, Czech Republic
[4] Slovak Univ Technol Bratislava, Inst Elect & Photon, Fac Elect Engn & Informat Technol, Ilkovicova 3, Bratislava 81219, Slovakia
关键词
Mephenoxalone; Voltammetry; Screen-printed sensor with boron-doped dia-mond electrode; GC-MS analysis; Spectroelectrochemistry; COMBINATION; BIOSENSORS; OXIDATION; TOXICITY; RATS;
D O I
10.1016/j.snb.2023.134700
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel screen-printed sensor (SPE) with boron-doped diamond electrode (BDDE) for determination of a muscle relaxant and mild anxiolytic mephenoxalone (MNL) was developed. The sensor utilizes the electrochemical oxidation of MNL, which was firstly studied in aqueous solution using oxygen terminated BDDE. MNL provided an irreversible anodic signal at a potential of + 1380 mV (vs. Ag/AgCl/KCl sat.) over a wide pH range. Britton-Robinson buffer (pH 9) was selected as a suitable electrolyte and the square-wave voltammetric method (SWV) was developed. The low detection limit (55 nmol L-1), wide linear dynamic range (0.1-30 mu mol L-1), and good recovery in the analysis of model and pharmaceutical samples (RSD < 1.77%) were attained. Subsequently, the new method was successfully transferred to SPE, which can find application in point-of-care testing. These sensors proved excellent sensitivity and reproducibility in the analysis of biological samples (RSD < 4.94%) without pretreatment and no need of electrolyte. Based on gas chromatography with mass spectrometry (GC-MS) analysis of preparative electrolysis products, a mechanism of the electrochemical oxidation of MNL was proposed, describing the oxidative cleavage of the alkoxybenzene ring. These results were supported with HOMO spatial distribution calculations and atomic charges calculations for arising radical cations, and with spectroelectrochemical measurements.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Boron-doped diamond electrode acting as a voltammetric sensor for the detection of methomyl pesticide
    Costa, Daniel J. E.
    Santos, Janete C. S.
    Sanches-Brandao, Fatima A. C.
    Ribeiro, Williame F.
    Salazar-Banda, Giancarlo R.
    Araujo, Mario C. U.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 789 : 100 - 107
  • [32] Voltammetric Sensor Based on Boron-Doped Diamond Electrode for Simultaneous Determination of Paracetamol, Caffeine, and Aspirin in Pharmaceutical Formulations
    Yigit, Aydin
    Yardim, Yavuz
    Senturk, Zuhre
    IEEE SENSORS JOURNAL, 2016, 16 (06) : 1674 - 1680
  • [33] Novel screen-printed sensors with chemically deposited boron-doped diamond and their use for voltammetric determination of attention deficit hyperactivity disorder medication atomoxetine
    Selesovska, Renata
    Navratil, Tomas
    Hrdlicka, Vojtech
    Michniak, Pavol
    Hatala, Michal
    Vojs, Marian
    Marton, Marian
    Matvieiev, Oleksandr
    Janikova, Lenka
    Chylkova, Jaromira
    ELECTROCHIMICA ACTA, 2022, 403
  • [34] Sensitive Voltammetric Detection of Chloroquine Drug by Applying a Boron-Doped Diamond Electrode
    Oliveira, Geiser Gabriel
    Azzi, Deborah Christine
    Silva, Tiago Almeida
    de Oliveira, Paulo Roberto
    Fatibello-Filho, Orlando
    Janegitz, Bruno Campos
    C-JOURNAL OF CARBON RESEARCH, 2020, 6 (04):
  • [35] Voltammetric determination of penicillin V in pharmaceutical formulations and human urine using a boron-doped diamond electrode
    Svorc, Lubomir
    Sochr, Jozef
    Rievaj, Miroslav
    Tomcik, Peter
    Bustin, Dusan
    BIOELECTROCHEMISTRY, 2012, 88 : 36 - 41
  • [36] Sensitive Voltammetric Quantification of Amlodipine in Pharmaceutical Tablets and Human Urine Using a Boron-Doped Diamond Electrode
    Cinkova, Kristina
    Svorc, L'ubomir
    XXXV MODERNI ELEKTROCHEMICKE METODY, 2015, : 17 - 21
  • [37] Fast and simple voltammetric sensing of avanafil in the pharmaceutical formulation by using unmodified boron-doped diamond electrode
    Ali, Hoshyar Saadi
    Barzani, Hemn A. H.
    Yardim, Yavuz
    ADMET AND DMPK, 2024, 12 (03): : 529 - 542
  • [38] Screen-printed sensor for determination of sildenafil citrate in pharmaceutical preparations and biological samples
    Sasal, Agnieszka
    Tyszczuk-Rotko, Katarzyna
    MICROCHEMICAL JOURNAL, 2019, 149
  • [39] Electrochemical behavior of methamphetamine and its voltammetric determination in biological samples using self-assembled boron-doped diamond electrode
    Svorc, L'ubomir
    Vojs, Marian
    Michniak, Pavol
    Marton, Marian
    Rievaj, Miroslav
    Bustin, Dusan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 717 : 34 - 40