Voltammetric analysis of mephenoxalone drug in pharmaceutical and biological samples using novel screen-printed sensor with boron-doped diamond electrode

被引:6
|
作者
Matvieiev, Oleksandr [1 ]
Selesovska, Renata [1 ]
Sokolova, Romana [2 ]
Jerga, Radek [3 ]
Skopalova, Jana [1 ,3 ]
Bartak, Petr [3 ]
Chylkova, Jaromira [1 ]
Vojs, Marian [4 ]
机构
[1] Univ Pardubice, Inst Environm & Chem Engn, Fac Chem Technol, Studentska 573, Pardubice 53210, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 3, Prague 18223, Czech Republic
[3] Palacky Univ, Fac Sci, Dept Analyt Chem, 17 listopadu 1192-12, Olomouc 77900, Czech Republic
[4] Slovak Univ Technol Bratislava, Inst Elect & Photon, Fac Elect Engn & Informat Technol, Ilkovicova 3, Bratislava 81219, Slovakia
关键词
Mephenoxalone; Voltammetry; Screen-printed sensor with boron-doped dia-mond electrode; GC-MS analysis; Spectroelectrochemistry; COMBINATION; BIOSENSORS; OXIDATION; TOXICITY; RATS;
D O I
10.1016/j.snb.2023.134700
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel screen-printed sensor (SPE) with boron-doped diamond electrode (BDDE) for determination of a muscle relaxant and mild anxiolytic mephenoxalone (MNL) was developed. The sensor utilizes the electrochemical oxidation of MNL, which was firstly studied in aqueous solution using oxygen terminated BDDE. MNL provided an irreversible anodic signal at a potential of + 1380 mV (vs. Ag/AgCl/KCl sat.) over a wide pH range. Britton-Robinson buffer (pH 9) was selected as a suitable electrolyte and the square-wave voltammetric method (SWV) was developed. The low detection limit (55 nmol L-1), wide linear dynamic range (0.1-30 mu mol L-1), and good recovery in the analysis of model and pharmaceutical samples (RSD < 1.77%) were attained. Subsequently, the new method was successfully transferred to SPE, which can find application in point-of-care testing. These sensors proved excellent sensitivity and reproducibility in the analysis of biological samples (RSD < 4.94%) without pretreatment and no need of electrolyte. Based on gas chromatography with mass spectrometry (GC-MS) analysis of preparative electrolysis products, a mechanism of the electrochemical oxidation of MNL was proposed, describing the oxidative cleavage of the alkoxybenzene ring. These results were supported with HOMO spatial distribution calculations and atomic charges calculations for arising radical cations, and with spectroelectrochemical measurements.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Electrochemical determination of nitazoxanide in environmental and pharmaceutical samples using a boron-doped diamond electrode
    Oliveira, Ana Clara M.
    Richter, Eduardo M.
    Paixao, Thiago R. L. C.
    Araujo, Diele A. G.
    Munoz, Rodrigo A. A.
    MICROCHEMICAL JOURNAL, 2024, 207
  • [22] Determination of tramadol in pharmaceutical forms and urine samples using a boron-doped diamond electrode
    Keskin, Ertugrul
    Allahverdiyeva, Shabnam
    Seyho, Esma
    Yardim, Yavuz
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2020, 85 (07) : 923 - 937
  • [23] Voltammetric determination of caffeine in beverage samples on bare boron-doped diamond electrode
    Svorc, Lubomir
    Tomcik, Peter
    Svitkova, Jana
    Rievaj, Miroslav
    Bustin, Dusan
    FOOD CHEMISTRY, 2012, 135 (03) : 1198 - 1204
  • [24] Effect of different modification by gold nanoparticles on the electrochemical performance of screen-printed sensors with boron-doped diamond electrode
    Matvieiev, Oleksandr
    Selesovska, Renata
    Marton, Marian
    Hatala, Michal
    Metelka, Radovan
    Weis, Martin
    Vojs, Marian
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [25] Activated Screen-Printed Boron-Doped Diamond Electrode for Rapid and Highly Sensitive Determination of Curcumin in Food Products
    Kozak, Jedrzej
    Tyszczuk-Rotko, Katarzyna
    Keller, Aleksy
    Wojciak, Magdalena
    Sowa, Ireneusz
    MATERIALS, 2023, 16 (21)
  • [26] Voltammetric method for sensitive determination of herbicide picloram in environmental and biological samples using boron-doped diamond film electrode
    Bandzuchova, Lenka
    Svorc, Lubomir
    Sochr, Jozef
    Svitkova, Jana
    Chylkova, Jaromira
    ELECTROCHIMICA ACTA, 2013, 111 : 242 - 249
  • [27] Effect of different modification by gold nanoparticles on the electrochemical performance of screen-printed sensors with boron-doped diamond electrode
    Oleksandr Matvieiev
    Renáta Šelešovská
    Marián Marton
    Michal Hatala
    Radovan Metelka
    Martin Weis
    Marian Vojs
    Scientific Reports, 13
  • [28] A New Electrochemical Sensor for the Detection of Azithromycin using Screen-Printed Carbon Electrode Modified with Boron-Doped Diamond Nanoparticles and Reduced-Graphene Oxide
    Jiwanti, Prastika K.
    Insani, Shafa A.
    Sari, Anis P.
    Wafiroh, Siti
    CHEMISTRYSELECT, 2024, 9 (21):
  • [29] Electrochemical study of the antiplatelet agent ticlopidine and its voltammetric determination in pharmaceutical and urine samples using a boron-doped diamond electrode
    Scremin, Jessica
    Karimi-Maleh, Hassan
    Sartori, Elen Romao
    ANALYTICAL METHODS, 2015, 7 (09) : 3750 - 3756
  • [30] An unmodified boron-doped diamond electrode for electroanalytical investigation and sensitive voltammetric quantification of antiviral drug famciclovir in the pharmaceutical formulation and serum samples
    Yardim, Yavuz
    Ali, Hoshyar Saadi
    Barzani, Hemn A. H.
    DIAMOND AND RELATED MATERIALS, 2022, 123