Enhanced visualization of mobile chest X-ray images in the intensive care setting using software scatter correction

被引:2
|
作者
Targett, Harry [1 ]
Hutchinson, Dominic [2 ]
Hartley, Richard [1 ]
McWilliam, Richard [3 ]
Lopez, Ben [3 ]
Crone, Ben [3 ]
Bonner, Stephen [2 ]
机构
[1] South Tees Hosp NHS Fdn Trust, James Cook Univ Hosp, Dept Clin Radiol, Middlesbrough, Cleveland, England
[2] South Tees Hosp NHS Fdn Trust, James Cook Univ Hosp, Dept Crit Care, Middlesbrough, Cleveland, England
[3] IBEX Innovat Ltd, Explorer 2,NET Pk, Sedgefield TS21 3FF, England
基金
“创新英国”项目;
关键词
Digital radiography; mobile chest X-ray; scatter correction; technology assessments; DOSE REDUCTION; RADIOGRAPHY; PERFORMANCE; QUALITY; ALIGNMENT; CONTRAST;
D O I
10.1177/02841851221087631
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Mobile chest X-ray (CXR) scans are performed within intensive treatment units (ITU) without anti-scatter grids for confirming tube and line hardware placement. Assessment is therefore challenging due to degraded subject contrast resulting from scatter. Purpose To evaluate the efficacy of a software scatter correction method (commercially named Trueview) for enhanced hardware visualization and diagnostic quality in the ITU setting. Material and Methods A total of 30 CXR scans were processed using Trueview and compared with standard original equipment manufacturer (OEM) images via observer scoring study involving two radiology and four ITU doctors to compare visualization of tubes and lines. Results were analyzed to determine observer preference and likelihood of diagnostic quality. Results Reviewers were more likely to score Trueview higher than OEM for mediastinal structures, bones, retrocardiac region, tube visibility, and tube safety (P < 0.01). Visual grading characteristic analysis suggested a clinical preference for Trueview compared with OEM for mediastinal structures (area under the visual grading characteristic curve [AUC(VGC)] = 0.60, 95% confidence interval [CI] = 0.55-0.65), bones (AUC(VGC) = 0.61, 95% CI = 0.55-0.66), retrocardiac region (AUC(VGC) = 0.64, 95% CI = 0.59-0.69), tube visibility (AUC(VGC) = 0.65, 95% CI = 0.60-0.70), and tube safety (AUC(VGC) = 0.68, 95% CI = 0.64-0.73). Reviewers were indifferent to visualization of the lung fields (AUC(VGC) = 0.49, 95% CI = 0.44-0.55). Registrars (3/6 reviewers) were indifferent to the mediastinal structure regions (AUC(VGC) = 0.54, 95% CI = 0.47-0.62). Conclusion Reviewers were more confident in identifying the placement and safety of tubes and lines when reviewing Trueview images than they were when reviewing OEM.
引用
收藏
页码:563 / 571
页数:9
相关论文
共 50 条
  • [31] Attention-enhanced architecture for improved pneumonia detection in chest X-ray images
    Li, Dikai
    BMC MEDICAL IMAGING, 2024, 24 (01)
  • [32] Four enhanced algorithms for full size image hiding in chest x-ray images
    Heednacram, Apichat
    Keaomanee, Yossawee
    MULTIMEDIA TOOLS AND APPLICATIONS, 2024, 83 (30) : 74855 - 74881
  • [33] Attention-enhanced architecture for improved pneumonia detection in chest X-ray images
    Dikai Li
    BMC Medical Imaging, 24
  • [34] The impact of X-ray scatter correction software on abdomen radiography in terms of image quality and radiation dose
    Sayed, M.
    Knapp, K. M.
    Fulford, J.
    Heales, C.
    Alqahtani, S. J.
    RADIOGRAPHY, 2024, 30 (04) : 1125 - 1135
  • [35] Enhanced COVID-19 Classification Using Ensemble Meta-Algorithms on Chest X-ray Images
    Menshawy, Lamiaa
    Eid, Ahmad H.
    Abdel-Kader, Rehab F.
    ENGINEERING SOLUTIONS TOWARD SUSTAINABLE DEVELOPMENT, ESSD 2023, 2024, : 485 - 497
  • [36] Modulator design for x-ray scatter correction using primary modulation: Material selection
    Gao, Hewei
    Zhu, Lei
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2010, 37 (08) : 4029 - 4037
  • [37] Scatter Correction for X-ray Imaging Using Primary Modulation: A Phantom Study for CBCT
    Zhu, Lei
    Bennett, Robert
    Fahrig, Rebecca
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1372 - +
  • [38] Scatter correction method for x-ray CT using primary modulation: Phantom studies
    Gao, Hewei
    Fahrig, Rebecca
    Bennett, N. Robert
    Sun, Mingshan
    Star-Lack, Josh
    Zhu, Lei
    MEDICAL PHYSICS, 2010, 37 (02) : 934 - 946
  • [39] COVID-19 prognosis using limited chest X-ray images
    Mondal, Arnab Kumar
    APPLIED SOFT COMPUTING, 2022, 122
  • [40] Automatic detection of pneumonia in chest X-ray images using textural features
    Ortiz-Toro, Cesar
    Garcia-Pedrero, Angel
    Lillo-Saavedra, Mario
    Gonzalo-Martin, Consuelo
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 145