Enhanced visualization of mobile chest X-ray images in the intensive care setting using software scatter correction

被引:2
|
作者
Targett, Harry [1 ]
Hutchinson, Dominic [2 ]
Hartley, Richard [1 ]
McWilliam, Richard [3 ]
Lopez, Ben [3 ]
Crone, Ben [3 ]
Bonner, Stephen [2 ]
机构
[1] South Tees Hosp NHS Fdn Trust, James Cook Univ Hosp, Dept Clin Radiol, Middlesbrough, Cleveland, England
[2] South Tees Hosp NHS Fdn Trust, James Cook Univ Hosp, Dept Crit Care, Middlesbrough, Cleveland, England
[3] IBEX Innovat Ltd, Explorer 2,NET Pk, Sedgefield TS21 3FF, England
基金
“创新英国”项目;
关键词
Digital radiography; mobile chest X-ray; scatter correction; technology assessments; DOSE REDUCTION; RADIOGRAPHY; PERFORMANCE; QUALITY; ALIGNMENT; CONTRAST;
D O I
10.1177/02841851221087631
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Mobile chest X-ray (CXR) scans are performed within intensive treatment units (ITU) without anti-scatter grids for confirming tube and line hardware placement. Assessment is therefore challenging due to degraded subject contrast resulting from scatter. Purpose To evaluate the efficacy of a software scatter correction method (commercially named Trueview) for enhanced hardware visualization and diagnostic quality in the ITU setting. Material and Methods A total of 30 CXR scans were processed using Trueview and compared with standard original equipment manufacturer (OEM) images via observer scoring study involving two radiology and four ITU doctors to compare visualization of tubes and lines. Results were analyzed to determine observer preference and likelihood of diagnostic quality. Results Reviewers were more likely to score Trueview higher than OEM for mediastinal structures, bones, retrocardiac region, tube visibility, and tube safety (P < 0.01). Visual grading characteristic analysis suggested a clinical preference for Trueview compared with OEM for mediastinal structures (area under the visual grading characteristic curve [AUC(VGC)] = 0.60, 95% confidence interval [CI] = 0.55-0.65), bones (AUC(VGC) = 0.61, 95% CI = 0.55-0.66), retrocardiac region (AUC(VGC) = 0.64, 95% CI = 0.59-0.69), tube visibility (AUC(VGC) = 0.65, 95% CI = 0.60-0.70), and tube safety (AUC(VGC) = 0.68, 95% CI = 0.64-0.73). Reviewers were indifferent to visualization of the lung fields (AUC(VGC) = 0.49, 95% CI = 0.44-0.55). Registrars (3/6 reviewers) were indifferent to the mediastinal structure regions (AUC(VGC) = 0.54, 95% CI = 0.47-0.62). Conclusion Reviewers were more confident in identifying the placement and safety of tubes and lines when reviewing Trueview images than they were when reviewing OEM.
引用
收藏
页码:563 / 571
页数:9
相关论文
共 50 条
  • [21] Classification of X-Ray Images of the Chest Using Convolutional Neural Networks
    Mochurad, Lesia
    Dereviannyi, Andrii
    Antoniv, Uliana
    IDDM 2021: INFORMATICS & DATA-DRIVEN MEDICINE: PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INFORMATICS & DATA-DRIVEN MEDICINE (IDDM 2021), 2021, 3038 : 269 - 282
  • [22] A Novel Model to Diagnose Pneumonia Using Chest X-ray Images
    Bagadi, Lavanya
    Panda, Shivani
    Pillalamarri, Praveen
    Hemanth, P.
    Kiran, V
    PROCEEDINGS OF SECOND INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTER ENGINEERING AND COMMUNICATION SYSTEMS, ICACECS 2021, 2022, : 317 - 323
  • [23] Ribs Suppression in Chest X-Ray Images by Using ICA Method
    Hieu Xuan Nguyen
    Tin Thanh Dang
    5TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING IN VIETNAM, 2015, 46 : 194 - 197
  • [24] Understanding Automatic Pneumonia Classification Using Chest X-Ray Images
    Bruno, Pierangela
    Calimeri, Francesco
    AIXIA 2020 - ADVANCES IN ARTIFICIAL INTELLIGENCE, 2021, 12414 : 37 - 50
  • [25] Deep learning models for tuberculosis detection and infected region visualization in chest X-ray images
    Sharma, Vinayak
    Nillmani
    Gupta, Sachin Kumar
    Shukla, Kaushal Kumar
    INTELLIGENT MEDICINE, 2024, 4 (02): : 104 - 113
  • [26] Lung Tumor Localization and Visualization in Chest X-Ray Images Using Deep Fusion Network and Class Activation Mapping
    Suryani, Ade Irma
    Chang, Chuan-Wang
    Feng, Yu-Fan
    Lin, Tin-Kwang
    Lin, Chih-Wen
    Cheng, Jen-Chieh
    Chang, Chuan-Yu
    IEEE ACCESS, 2022, 10 : 124448 - 124463
  • [27] Chest X-ray image quality assessment in a pediatric cardiac intensive care unit
    Martire, F.
    Polito, C.
    Ciucci, D.
    Camillocci, E. Solfaroli
    Longo, M.
    Genovese, E.
    Cirillo, M.
    Toma, P.
    Magistrelli, A.
    Cannata, V.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 205
  • [28] Clinical relevance of the routine daily chest X-Ray in the surgical intensive care unit
    Resnick, Shelby
    Inaba, Kenji
    Karamanos, Efstathios
    Skiada, Dimitra
    Dollahite, James A.
    Okoye, Obi
    Talving, Peep
    Demetriades, Demetrios
    AMERICAN JOURNAL OF SURGERY, 2017, 214 (01): : 19 - 23
  • [29] Optimized protocol for repeated chest X-ray in a pediatric cardiac intensive care unit
    Polito, C.
    Genovese, E.
    Longo, M.
    Cassano, B.
    Donatiello, S.
    Secinaro, A.
    Magistrelli, A.
    Toma, P.
    Cannata, V.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 179 (179)
  • [30] Enhanced X-ray images using amorphous silicon arrays
    Hartman, WF
    Boltz, ES
    NONDESTRUCTIVE EVALUATION OF AGING MATERIALS AND COMPOSITES III, 1999, 3585 : 59 - 66