Partial Discharge Detection and Defect Location Method in GIS Cable Terminal

被引:8
|
作者
Li, Songyuan [1 ]
Song, Pengxian [1 ]
Wei, Zhanpeng [2 ]
Li, Xu [1 ]
Tang, Qinghua [1 ]
Meng, Zhengzheng [1 ]
Li, Ji [3 ]
Liu, Songtao [1 ]
Wang, Yuhuai [4 ]
Li, Jin [4 ]
机构
[1] State Grid Tianjin Elect Power Res Inst, Tianjin 300384, Peoples R China
[2] Power Cable Co, Tianjin 300300, Peoples R China
[3] State Grid Tianjin Elect Power Co, Tianjin 300100, Peoples R China
[4] Tianjin Univ, Sch Elect & Informat Engn, Key Lab Smart Grid Educ Minist, Tianjin 300072, Peoples R China
关键词
GIS cable termination; UHF; joint diagnoses; dissection analysis; electric field distribution; EXTREME WEATHER; RESILIENCE; INSULATION; SYSTEMS; MODEL;
D O I
10.3390/en16010413
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The complex structure of gas-insulated switchgear (GIS) cable terminals leads to serious electric field concentration, which is a frequent fault position of a high-voltage cable system. At present, due to the differences in the frequency bands of sensors, various partial discharge detection technologies have certain differences in their scope of application and anti-interference performance, resulting in a low defect detection rate in GIS cable terminals. In this paper, a comprehensive diagnosis scheme is proposed, which integrates transient earth voltage (TEV), ultra-high frequency (UHF), high frequency (HF), and ultrasonic methods. Two abnormal discharge defects of GIS terminals in two 220 kV substations in Tianjin were tracked and monitored, and the joint diagnosis was carried out using the proposed scheme; the type of discharge defect and the phase sequence of the defect were determined, and the UHV was employed to precisely locate and analyze the defect source. Finally, through the disassembly analysis and electric field simulation of the GIS cable terminal, the accuracy and effectiveness of the discharge detection and location method were verified, providing a typical detection demonstration for the defect diagnosis of a GIS cable terminal.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Simulation of Underground Cable Defects with the Detection of Partial Discharge
    Delvadiya, Hardikkumar
    Kumar, Dinesh
    Patel, Krishna
    INTELLIGENT MANUFACTURING AND ENERGY SUSTAINABILITY, ICIMES 2019, 2020, 169 : 499 - 507
  • [32] Defect Diagnosis of Cable Insulating Materials by Partial Discharge Statistical Analysis
    Shin, Jong-Yeol
    Park, Hee-Doo
    Lee, Jong-Yong
    Hong, Jin-Woong
    TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2010, 11 (01) : 42 - 47
  • [33] Defect Diagnosis of the Cable Insulating Materials by Partial Discharge Statistical Analysis
    Park, Hee-Doo
    Kim, Joung-Sik
    Jeong, In-Bum
    Choi, Kwang-Jin
    Ryu, Boo-Hyung
    Hong, Jin-Woong
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 293 - +
  • [34] Partial Discharge Location for Power Cable Based on the Time Reversal Technique
    Xie M.
    Zhou K.
    He M.
    Zhao S.
    Zhang F.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2018, 38 (11): : 3402 - 3409
  • [35] Partial Discharge Characterization in a Defect Subjected to HVDC Cable Operating Conditions
    Imburgia, A.
    Rizzo, G.
    Ala, G.
    Hammarstrom, T. J. A.
    Serdyuk, Y. V.
    Di Fatta, A.
    Romano, P.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (04) : 1729 - 1737
  • [36] Research on Insulation Defect Diagnosis Method of XLPE AC Cable based on Partial Discharge Image Feature
    Zhang, Yue
    Wu, Chen
    Fang, Ruifeng
    Huang, Guanglei
    Li, Zhe
    Sheng, Gehao
    2018 12TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM 2018), 2018, : 662 - 665
  • [37] Single-Sided Partial Discharge Location Method Based on Impedance Discontinuities along Power Cable
    Li, Yan
    Wouters, Peter A. A. F.
    Wagenaarst, Paul
    van der Wielent, Peter C. J. M.
    Steennist, E. Fred
    2014 POWER SYSTEMS COMPUTATION CONFERENCE (PSCC), 2014,
  • [38] Practical location method of transformer partial discharge
    Li, YQ
    Lu, FC
    Xie, HL
    Yin, M
    2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, 2004, : 1371 - 1374
  • [39] Detection Method of Partial Discharge in XLPE Cable Accessories Based on the Method of VHF Combined with Acoustic Emission
    Wang, Wei
    Cheng, Xu
    Liu, Chong
    Yang, Defu
    Shen, Xueliang
    Zong, Fei
    ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 142 - 142
  • [40] Partial discharge diagnosis on GIS based on envelope detection
    Dept. of Electrical Engineering, Shanghai Jiao Tong University, 800, Dongchuan Road, Shanghai, China
    WSEAS Trans. Syst., 2008, 11 (1238-1247):