Partial Discharge Detection and Defect Location Method in GIS Cable Terminal

被引:8
|
作者
Li, Songyuan [1 ]
Song, Pengxian [1 ]
Wei, Zhanpeng [2 ]
Li, Xu [1 ]
Tang, Qinghua [1 ]
Meng, Zhengzheng [1 ]
Li, Ji [3 ]
Liu, Songtao [1 ]
Wang, Yuhuai [4 ]
Li, Jin [4 ]
机构
[1] State Grid Tianjin Elect Power Res Inst, Tianjin 300384, Peoples R China
[2] Power Cable Co, Tianjin 300300, Peoples R China
[3] State Grid Tianjin Elect Power Co, Tianjin 300100, Peoples R China
[4] Tianjin Univ, Sch Elect & Informat Engn, Key Lab Smart Grid Educ Minist, Tianjin 300072, Peoples R China
关键词
GIS cable termination; UHF; joint diagnoses; dissection analysis; electric field distribution; EXTREME WEATHER; RESILIENCE; INSULATION; SYSTEMS; MODEL;
D O I
10.3390/en16010413
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The complex structure of gas-insulated switchgear (GIS) cable terminals leads to serious electric field concentration, which is a frequent fault position of a high-voltage cable system. At present, due to the differences in the frequency bands of sensors, various partial discharge detection technologies have certain differences in their scope of application and anti-interference performance, resulting in a low defect detection rate in GIS cable terminals. In this paper, a comprehensive diagnosis scheme is proposed, which integrates transient earth voltage (TEV), ultra-high frequency (UHF), high frequency (HF), and ultrasonic methods. Two abnormal discharge defects of GIS terminals in two 220 kV substations in Tianjin were tracked and monitored, and the joint diagnosis was carried out using the proposed scheme; the type of discharge defect and the phase sequence of the defect were determined, and the UHV was employed to precisely locate and analyze the defect source. Finally, through the disassembly analysis and electric field simulation of the GIS cable terminal, the accuracy and effectiveness of the discharge detection and location method were verified, providing a typical detection demonstration for the defect diagnosis of a GIS cable terminal.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] NEW PARTIAL DISCHARGE DETECTION METHOD FOR LIVE UHV EHV CABLE JOINTS
    FUKUNAGA, K
    TAN, M
    TAKEHANA, H
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1992, 27 (03): : 669 - 674
  • [22] New partial discharge detection method for live UHV/EHV cable joints
    Fukunaga, K.
    Tan, M.
    Takehana, H.
    IEEE transactions on electrical insulation, 1992, 27 (02): : 669 - 674
  • [23] A sensitive method for on-site partial discharge detection on XLPE cable joints
    Schichler, U
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 1997, : 1099 - 1102
  • [24] Partial discharge location of power cables based on an improved single-terminal method
    Liang, Rui
    Zhang, Zhe
    Li, Hailong
    Chi, Peng
    Li, Guoxin
    Tao, Yunchun
    Electric Power Systems Research, 2021, 193
  • [25] Partial discharge location of power cables based on an improved single-terminal method
    Liang, Rui
    Zhang, Zhe
    Li, Hailong
    Chi, Peng
    Li, Guoxin
    Tao, Yunchun
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 193
  • [26] Partial discharge detection in GIS using ultra-high-frequency method
    Sun, Yanzhou
    Wang, Xudong
    Yin, Hua
    Yu, Fashan
    ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 695 - +
  • [27] Measurement and Analysis of Partial Discharge on Floating Electrode Defect in GIS
    Yao, Rui
    Zhang, Yanbin
    Si, Gangquan
    Yuan, Yiwei
    Xie, Qian
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [28] Study on partial discharge of metallic outshoot insulation defect in GIS
    Qian, Z
    Ju, T
    Xu, ZR
    Meng, YH
    Zhang, XX
    Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 431 - 434
  • [29] Application of HF/UHF joint partial discharge analysis to on-site power cable terminal detection
    Guo, Canxin
    Zhang, Lianhong
    Yao, Linpeng
    Qian, Yong
    Huang, Chengjun
    Jiang, Xiuchen
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2010, 30 (05): : 92 - 95
  • [30] Investigation on Partial Discharge Inception Voltage and Discharge Pattern of Simulated Defect Cable System
    Suwanasri, C.
    Sangpakdeejit, T.
    Vipulum, N.
    Fuangpian, P.
    Ruankon, S.
    Suwanasri, T.
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 238 - 241