Nafion-Titanium (IV) Oxide-Graphene Modified Glassy Carbon Electrode (GCE) Based Electrochemical Sensor for the Voltammetric Determination of the β-blocker Bisoprolol Fumarate

被引:2
|
作者
Kocak, Berna [1 ,2 ]
Ipek, Yeliz [1 ,2 ]
机构
[1] Munzur Univ, Vocat Sch Tunceli, Chem & Chem Proc Technol Dept, Tunceli, Turkey
[2] Munzur Univ, Rare Earth Element Res & Applicat Ctr, Tunceli, Turkey
关键词
Bisoprolol fumarate; differential pulse voltammetry (DPV); electrochemical sensor; graphene; titanium (IV) oxide; PASTE ELECTRODE; AMLODIPINE BESYLATE; TIO2; NANOPARTICLES; HPLC METHOD; HYDROCHLOROTHIAZIDE; VALIDATION; ACETAMINOPHEN; FORMULATIONS; NANOSHEETS; DESIGN;
D O I
10.1080/00032719.2022.2139837
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Nafion-titanium (IV) oxide-graphene modified glassy carbon electrode (n-TiO2-GR/GCE) was used for the electrochemical determination of bisoprolol fumarate (BF). The modified electrode was prepared by depositing Nafion-titanium (IV) oxide-graphene onto the glassy carbon electrode by simple drop-casting. Differential pulse voltammetry (DPV) and square wave voltammetry (SWV) were used in the electrochemical determination of bisoprolol fumarate. The linear working range of bisoprolol fumarate for n-TiO2-GR/GCE DPV was from 3.0 x 10(-7) to 5.0 x 10(-6 )mol L-1 and the detection limit was 1.01 x 10(-7 )mol L-1. In addition, with this developed method, the determination of bisoprolol fumarate in tablets was successfully performed with a recovery of 98.65%.
引用
收藏
页码:1619 / 1631
页数:13
相关论文
共 50 条
  • [21] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Yazhen Wang
    Bin Song
    Junhui Xu
    Shengshui Hu
    Microchimica Acta, 2015, 182 : 711 - 718
  • [22] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Wang, Yazhen
    Song, Bin
    Xu, Junhui
    Hu, Shengshui
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 711 - 718
  • [23] Electrochemical Rutin Sensor Based on Graphene Oxide and Functionalized Multiwall Carbon Nanotubes@nafion0.1% Hybrid Nanocomposite modified glassy carbon electrode
    Kumar, Praveen G.
    Nehru, Raja
    Chen, Shen-Ming
    Almunqedhi, Bandar Mohsen
    Chen, Tse-Wei
    Wang, Jun-Yu
    Yu, Ming-Chin
    Darwish, Noura M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (07): : 6065 - 6076
  • [24] Nafion-graphene composite film modified glassy carbon electrode for voltammetric determination of p-aminophenol
    Hayati Filik
    Gamze Çetintaş
    Serkan Naci Koç
    Handan Gülce
    İsmail Boz
    Russian Journal of Electrochemistry, 2014, 50 : 243 - 252
  • [25] A novel poly(cyanocobalamin) modified glassy carbon electrode as electrochemical sensor for voltammetric determination of peroxynitrite
    Wang, Yan
    Chen, Zhen-zhen
    TALANTA, 2010, 82 (02) : 534 - 539
  • [26] Nafion-Graphene Composite Film Modified Glassy Carbon Electrode for Voltammetric Determination of p-Aminophenol
    Filik, Hayati
    Cetintas, Gamze
    Koc, Serkan Naci
    Gulce, Handan
    Boz, Ismail
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (03) : 243 - 252
  • [27] Sensitive Voltammetric Determination of Baicalein at Thermally Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Zhang, Yanmin
    He, Langchong
    ELECTROANALYSIS, 2013, 25 (09) : 2136 - 2144
  • [28] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Yang, Suling
    Qu, Lingbo
    Yang, Ran
    Li, Jianjun
    Yu, Lanlan
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (07) : 1371 - 1378
  • [29] Electrochemical Sensor Based on Nafion/Gold Nanoparticle/Electrochemically Reduced Graphene Oxide Composite-Modified Glassy Carbon Electrode for the Detection of Diuron
    Qin, Jianfang
    Qin, YingLian
    Jiang, Xiuping
    Du, Yajin
    Du, Yajing
    Yao, Chen-Zhong
    Wang, Xi
    Yang, Haiying
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (11): : 11203 - 11214
  • [30] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Suling Yang
    Lingbo Qu
    Ran Yang
    Jianjun Li
    Lanlan Yu
    Journal of Applied Electrochemistry, 2010, 40 : 1371 - 1378