AC susceptibility measurement of magnetic nanoparticles using an optically pumped magnetometer and a flux transformer

被引:2
|
作者
Sasayama, Teruyoshi [1 ]
Taue, Shuji [2 ]
Yoshida, Takashi [1 ]
机构
[1] Kyushu Univ, Dept Elect & Elect Engn, Fukuoka 8190395, Japan
[2] Kochi Univ Technol, Sch Syst Engn, Kochi 7828502, Japan
基金
日本学术振兴会;
关键词
MAGNETORELAXOMETRY; MRI; OPTIMIZATION; SPECTROSCOPY; SYSTEM; FIELDS; MPI;
D O I
10.1063/9.0000634
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Magnetic particle imaging (MPI) is used to detect small magnetic fields in magnetic nanoparticles (MNPs). As a first step in MPI systems, we proposed an AC susceptibility measurement system with an optically pumped magnetometer (OPM) based on a flux transformer. First, the magnetic frequency response of the OPM was obtained for calibration. Second, the AC susceptibility of the Resovist MNPs in liquid and solid phases was obtained using the calibration data. These results are consistent with those of previous studies. Therefore, the proposed method is useful for detecting weak MNP magnetic signals in relatively strong magnetic fields and is expected to be applicable to MPI.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Magnetic shieldless ultra-low-field MRI with an optically pumped magnetometer
    Hori, Sogo
    Oida, Takenori
    Moriya, Takahiro
    Saito, Akinori
    Suyama, Motohiro
    Kobayashi, Tetsuo
    JOURNAL OF MAGNETIC RESONANCE, 2022, 343
  • [32] Magnetic Field Vector Detection in Frequency Domain with an Optically Pumped Atomic Magnetometer
    Mizutani, Natsuhiko
    Kobayashi, Tetsuo
    IEEE TRANSACTIONS ON MAGNETICS, 2012, 48 (11) : 4096 - 4099
  • [33] Integrated Optically Pumped Magnetometer for Measurements within Earth's Magnetic Field
    Oelsner, G.
    IJsselsteijn, R.
    Scholtes, T.
    Krueger, A.
    Schultze, V
    Seyffert, G.
    Werner, G.
    Jaeger, M.
    Chwala, A.
    Stolz, R.
    PHYSICAL REVIEW APPLIED, 2022, 17 (02)
  • [34] Flux relaxation and ac magnetic susceptibility of superconductor
    Vysotskii, VV
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1996, 46 : 905 - 906
  • [35] Differential behavior of magnetic field and magnetic vector potential in an optically pumped Rb atomic magnetometer
    Shoji, Y.
    Daibo, M.
    AIP ADVANCES, 2023, 13 (02)
  • [36] MEASUREMENT OF MAGNETIC SUSCEPTIBILITY WITH THE AID OF A QUANTUM MAGNETOMETER.
    Kuznetsov, V.D.
    Soviet physics journal, 1984, 27 (02): : 118 - 126
  • [37] Measurement of the nuclear polarisation of optically pumped He-3 atoms using a He-4 magnetometer
    Noel, E
    Gilles, H
    Hamel, J
    Moreau, O
    Cheron, B
    JOURNAL DE PHYSIQUE III, 1996, 6 (08): : 1127 - 1132
  • [38] In Situ Measurement of Nonorthogonal Angles of a Three-Axis Vector Optically Pumped Magnetometer
    Li, Siran
    Lu, Jixi
    Ma, Danyue
    Wang, Kun
    Gao, Yanan
    Sun, Chang
    Han, Bangcheng
    IEEE Transactions on Instrumentation and Measurement, 2022, 71
  • [39] In Situ Measurement of Nonorthogonal Angles of a Three-Axis Vector Optically Pumped Magnetometer
    Li, Siran
    Lu, Jixi
    Ma, Danyue
    Wang, Kun
    Gao, Yanan
    Sun, Chang
    Han, Bangcheng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [40] Optically Pumped Quantum Magnetometer Employing Two Components of Magnetic Moment Precession Signal
    Vershovskii, A. K.
    Pazgalev, A. S.
    TECHNICAL PHYSICS LETTERS, 2011, 37 (01) : 23 - 26