In Situ Measurement of Nonorthogonal Angles of a Three-Axis Vector Optically Pumped Magnetometer

被引:22
|
作者
Li, Siran [1 ,2 ]
Lu, Jixi [3 ,4 ,5 ]
Ma, Danyue [1 ]
Wang, Kun [1 ]
Gao, Yanan [1 ]
Sun, Chang [3 ,4 ,5 ]
Han, Bangcheng [3 ,4 ,5 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Beijing 100191, Peoples R China
[2] Beihang Univ, Shenyuan Honors Coll, Beijing 100191, Peoples R China
[3] Beihang Univ, Inst Frontier Sci, Beijing 100191, Peoples R China
[4] Beihang Univ, Hangzhou Innovat Inst, Hangzhou 310051, Peoples R China
[5] Zhejiang Lab, Hangzhou 311121, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetometers; Optical beams; Coils; Atomic measurements; Optical variables measurement; Atomic beams; Atom optics; Misalignment; nonorthogonality; optically pumped magnetometer (OPM); triaxial coils; vector atomic magnetometers; COIL SYSTEMS; CALIBRATION;
D O I
10.1109/TIM.2022.3144737
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An in situ method has been proposed for measuring all nonorthogonal angles of the beams and triaxial coils in a three-axis vector optically pumped magnetometer (OPM). Based on the combination and alignment of two pump beams, each of which can achieve biaxial transverse measurement in a time-sharing regime under modulated magnetic fields, a 3-D orthogonal coordinate measurement system is obtained, and the measurement models for three categories (six types) of nonorthogonal angles are established theoretically. On this basis, we experimentally measured the nonorthogonal angles along with related uncertainties at different modulated frequencies and strengths of the magnetic fields. The nonorthogonal angles were (3.65 degrees +/- 0.52 degrees) between the two pump beams before compensation. They were (7.05 degrees +/- 0.23 degrees) between the X- and Y-axis coils, (8.89 degrees +/- 0.21 degrees) between the Y- and Z-axis coils, (5.23 degrees +/- 0.27 degrees) between the X- and Z-axis coils, (7.24 degrees +/- 0.24 degrees) between the x-direction pump beam and X-axis coil, and (9.10 degrees +/- 0.22 degrees) between the z-direction pump beam and the Z-axis coil. This study measures the magnitudes of six types of nonorthogonality, without making an assumption of ideal orthogonality or using auxiliary calibration equipment. Moreover, this method can be extended to several other kinds of OPMs with simple modifications. This study is critical for evaluating and reducing the misalignment error to improve the accuracy of three-axis vector OPMs.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] In Situ Measurement of Nonorthogonal Angles of a Three-Axis Vector Optically Pumped Magnetometer
    Li, Siran
    Lu, Jixi
    Ma, Danyue
    Wang, Kun
    Gao, Yanan
    Sun, Chang
    Han, Bangcheng
    IEEE Transactions on Instrumentation and Measurement, 2022, 71
  • [2] Three-axis closed-loop optically pumped magnetometer operated in the SERF regime
    Yan, Yeguang
    Lu, Jixi
    Zhang, Shaowen
    Lu, Fei
    Yin, Kaifeng
    Wang, Kun
    Zhou, Binquan
    Liu, Gang
    OPTICS EXPRESS, 2022, 30 (11) : 18300 - 18309
  • [3] Three-Axis Vector Magnetometer with a Three-Dimensional Flux Concentrator
    Chen, Shih-Jui
    Hong, Der-Tai
    Hsieh, Ping-Hsun
    Wang, Tse-Kang
    SENSORS, 2024, 24 (05)
  • [4] A three-axis SQUID-based absolute vector magnetometer
    Schoenau, T.
    Zakosarenko, V.
    Schmelz, M.
    Stolz, R.
    Anders, S.
    Linzen, S.
    Meyer, M.
    Meyer, H. -G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (10):
  • [5] On Calibration of Three-Axis Magnetometer
    Wu, Yuanxin
    Shi, Wei
    IEEE SENSORS JOURNAL, 2015, 15 (11) : 6424 - 6431
  • [6] In Situ Magnetic Field Compensation Method for Optically Pumped Magnetometers Under Three-Axis Nonorthogonality
    Long, Tengyue
    Song, Xinda
    Han, Bangcheng
    Suo, Yuchen
    Jia, Le
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [7] Miniature Wide-Range Three-Axis Vector Atomic Magnetometer
    Li, Jianjun
    Deng, Yicheng
    Wang, Xuefeng
    Lu, Hang
    Liu, Yuanxing
    IEEE SENSORS JOURNAL, 2021, 21 (21) : 23943 - 23948
  • [8] Absolute calibration of a three-axis SQUID-cascade vector magnetometer
    Schoenau, T.
    Zakosarenko, V.
    Schmelz, M.
    Stolz, R.
    Anders, S.
    Linzen, S.
    Meyer, M.
    Fassbinder, J. W. E.
    Meyer, H-G
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (01)
  • [9] An algorithm for calibrating the three-axis magnetometer
    Emaletdinova L.Y.
    Gainutdinova A.V.
    Gainutdinova T.Y.
    Russian Aeronautics, 2017, 60 (1): : 134 - 140
  • [10] Three-axis magnetometer orbit determination
    Wu, Mei-Ping
    Tian, Jing
    Hu, Xiao-Ping
    Guofang Keji Daxue Xuebao/Journal of National University of Defense Technology, 2002, 24 (03):