In Situ Measurement of Nonorthogonal Angles of a Three-Axis Vector Optically Pumped Magnetometer

被引:22
|
作者
Li, Siran [1 ,2 ]
Lu, Jixi [3 ,4 ,5 ]
Ma, Danyue [1 ]
Wang, Kun [1 ]
Gao, Yanan [1 ]
Sun, Chang [3 ,4 ,5 ]
Han, Bangcheng [3 ,4 ,5 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Beijing 100191, Peoples R China
[2] Beihang Univ, Shenyuan Honors Coll, Beijing 100191, Peoples R China
[3] Beihang Univ, Inst Frontier Sci, Beijing 100191, Peoples R China
[4] Beihang Univ, Hangzhou Innovat Inst, Hangzhou 310051, Peoples R China
[5] Zhejiang Lab, Hangzhou 311121, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetometers; Optical beams; Coils; Atomic measurements; Optical variables measurement; Atomic beams; Atom optics; Misalignment; nonorthogonality; optically pumped magnetometer (OPM); triaxial coils; vector atomic magnetometers; COIL SYSTEMS; CALIBRATION;
D O I
10.1109/TIM.2022.3144737
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An in situ method has been proposed for measuring all nonorthogonal angles of the beams and triaxial coils in a three-axis vector optically pumped magnetometer (OPM). Based on the combination and alignment of two pump beams, each of which can achieve biaxial transverse measurement in a time-sharing regime under modulated magnetic fields, a 3-D orthogonal coordinate measurement system is obtained, and the measurement models for three categories (six types) of nonorthogonal angles are established theoretically. On this basis, we experimentally measured the nonorthogonal angles along with related uncertainties at different modulated frequencies and strengths of the magnetic fields. The nonorthogonal angles were (3.65 degrees +/- 0.52 degrees) between the two pump beams before compensation. They were (7.05 degrees +/- 0.23 degrees) between the X- and Y-axis coils, (8.89 degrees +/- 0.21 degrees) between the Y- and Z-axis coils, (5.23 degrees +/- 0.27 degrees) between the X- and Z-axis coils, (7.24 degrees +/- 0.24 degrees) between the x-direction pump beam and X-axis coil, and (9.10 degrees +/- 0.22 degrees) between the z-direction pump beam and the Z-axis coil. This study measures the magnitudes of six types of nonorthogonality, without making an assumption of ideal orthogonality or using auxiliary calibration equipment. Moreover, this method can be extended to several other kinds of OPMs with simple modifications. This study is critical for evaluating and reducing the misalignment error to improve the accuracy of three-axis vector OPMs.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Calibration Method of Three-Axis Magnetometer Based on Sine Fitting
    Jia W.
    Lin C.
    Lin P.
    Zhai G.
    Wuhan Daxue Xuebao (Xinxi Kexue Ban)/Geomatics and Information Science of Wuhan University, 2019, 44 (09): : 1328 - 1333and1406
  • [32] Calibration of QM-MOURA three-axis magnetometer and gradiometer
    Diaz-Michelena, M.
    Sanz, R.
    Cerdan, M. F.
    Fernandez, A. B.
    GEOSCIENTIFIC INSTRUMENTATION METHODS AND DATA SYSTEMS, 2015, 4 (01) : 1 - 18
  • [33] Real-time Calibration Algorithm for Three-axis Magnetometer
    Zhao, Heda
    Lin, Chunsheng
    Zhang, Hongxin
    Zhai, Guojun
    PROCEEDINGS OF THE 2016 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL & ELECTRONICS ENGINEERING AND COMPUTER SCIENCE (ICEEECS 2016), 2016, 50 : 297 - 300
  • [34] Remotely-interrogated three-axis fiber laser magnetometer
    Cranch, G. A.
    Miller, G. A.
    Askins, C. G.
    Kirkendall, C. K.
    Bartolo, R. E.
    2011 IEEE SENSORS, 2011, : 2006 - 2009
  • [35] Three-axis atomic magnetometer for nuclear magnetic resonance gyroscopes
    Qiu, Xuyang
    Xu, Zhengyi
    Peng, Xinxin
    Li, Lianhua
    Zhou, Yinmin
    Wei, Mengmeng
    Zhou, Min
    Xu, Xinye
    APPLIED PHYSICS LETTERS, 2020, 116 (03)
  • [36] Computationally Efficient Calibration Algorithm for Three-Axis Accelerometer and Magnetometer
    Papafotis, Konstantinos
    Sotiriadis, Paul P.
    2019 8TH INTERNATIONAL CONFERENCE ON MODERN CIRCUITS AND SYSTEMS TECHNOLOGIES (MOCAST), 2019,
  • [37] A Novel Linear Calibration Model for Three-Axis Fluxgate Magnetometer
    Liu, Jianguo
    Li, Xiangang
    Yan, Shenggang
    Yan, Youyu
    Jia, Wei
    Zhang, Qingguo
    IEEE SENSORS JOURNAL, 2021, 21 (21) : 23917 - 23925
  • [38] High bandwidth three-axis magnetometer based on optically polarized 85Rb under unshielded environment
    Yang, Hongying
    Zhang, Ke
    Wang, Yanhua
    Zhao, Nan
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2020, 53 (06)
  • [39] Single-beam three-axis optically pumped magnetometers with sub-100 femtotesla sensitivity
    Xiao, Wei
    Wu, Yulong
    Zhang, Xiangzhi
    Feng, Yulong
    Sun, Chenxi
    Wu, Teng
    Chen, Jingbiao
    Peng, Xiang
    Guo, Hong
    APPLIED PHYSICS EXPRESS, 2021, 14 (06)
  • [40] Optically pumped vector magnetometer using a strong bias magnetic field
    Schoenau, Thomas
    Scholtes, Theo
    Wittkaemper, Florian
    Sekels, Alexander
    Hiebel, Stefan
    Oelsner, Gregor
    Stolz, Ronny
    PHYSICAL REVIEW APPLIED, 2025, 23 (02):