Theoretical and experimental study of waste-heat-recovery boiler with water injection

被引:1
|
作者
Shin, Jaehun [1 ]
Park, Taejoon [1 ]
Cho, Hyunseok [2 ]
Yoo, Junsang [2 ]
Moon, Seoksu [1 ,3 ]
Lee, Changeon [1 ,3 ]
机构
[1] Inha Univ, Dept Mech Engn, Inchon, South Korea
[2] Inha Univ, Korea Initiat Fostering Univ Res & Innovat, Incheon, South Korea
[3] 100 Inha Ro, Incheon 22212, South Korea
关键词
Condensing boiler; Waste-heat-recovery; Water injection; Thermal efficiency; Nitrogen oxides (NOx); EXHAUST-GAS RECIRCULATION; COMBUSTION CHARACTERISTICS; THERMAL EFFICIENCY; IMPROVEMENT;
D O I
10.1016/j.heliyon.2023.e19417
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The waste-heat-recovery boiler with water injection (HR-B/W) applies the heat exchange between the intake air and exhaust gas with the water injection into the intake air. Previous theoretical studies have discussed that the HR-B/W would increase the thermal efficiency of the boiler by the active heat exchange between the intake air and exhaust gas. It has also been discussed that the increased fraction of water vapor in the air would reduce the flame temperature which in turn decreases the NOx emission. However, the potential performance of the HR-B/W has not been validated through practical boiler tests by considering the evaporation characteristics of the injected water, which plays a critical role in the performance of the HR-B/W. In this study the effects of water injection into the intake air on the thermal efficiency and pollutant emissions of the waste-heat-recovery boiler are investigated using a commercial 24 kW condensing boiler in full load condition. Thermodynamic analysis is performed to evaluate the adequate amount of water injection and trace the physical properties in the boiler upon the water injection amount and evaporation characteristics. The boiler test results showed water injection can increase thermal efficiency to 4.4% point and reduce NOx and CO emissions by 69% and 33% respectively compared to those without water injection. These advantages can be further enhanced if the atomization and evaporation performance of injected water is improved.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Development of integrated technology for waste heat recovery from humid flue gas of hot water boiler
    Cui, Zhaoyang
    Du, Qian
    Gao, Jianmin
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (13) : 19560 - 19573
  • [33] Optimization of waste heat recovery boiler of a combined cycle power plant
    Seyedan, B
    Dhar, PL
    Gaur, RR
    Bindra, GS
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 561 - 564
  • [34] Deposition of cement kiln ash on the tubes of waste heat recovery boiler
    Wang, Yufeng
    Hu, Chunyun
    Hui, Shi'en
    Zhao, Qinxin
    Zhou, Qulan
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [35] Heat and mass transfer analysis in a solar water recovery device: Experimental and theoretical distillate output study
    Fang, Shibiao
    Mu, Lin
    Tu, Wenrong
    DESALINATION, 2021, 500
  • [36] The Design and Experimental Study of a Deep-Condensing Waste Heat Recovery System for Boiler Flue Gas Based on Baoneng Heating Plant
    Zhang, Shaolin
    Shen, Miao
    Kang, Yuzhen
    Tang, Zhiwei
    PROCESSES, 2025, 13 (02)
  • [37] Numerical study on steam injection in a turbocompound diesel engine for waste heat recovery
    Zhao, Rongchao
    Li, Weihua
    Zhuge, Weilin
    Zhang, Yangjun
    Yin, Yong
    APPLIED ENERGY, 2017, 185 : 506 - 518
  • [38] Experimental study on heat pipe assisted heat exchanger used for industrial waste heat recovery
    Ma, Hongting
    Yin, Lihui
    Shen, Xiaopeng
    Lu, Wenqian
    Sun, Yuexia
    Zhang, Yufeng
    Deng, Na
    APPLIED ENERGY, 2016, 169 : 177 - 186
  • [39] Waste Heat Recovery System Using Coal-Fired Boiler Flue Gas to Heat Heating Network Return Water
    Zhao, Hua
    Dai, Pengfei
    Cao, Shanshan
    Hao, Qing
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 567 - 575
  • [40] An experimental and theoretical investigation into the heat transfer of a finned water wall tube in a circulating fluidized bed boiler
    Basu, P
    Cheng, LM
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2000, 24 (04) : 291 - 308