Theoretical and experimental study of waste-heat-recovery boiler with water injection

被引:1
|
作者
Shin, Jaehun [1 ]
Park, Taejoon [1 ]
Cho, Hyunseok [2 ]
Yoo, Junsang [2 ]
Moon, Seoksu [1 ,3 ]
Lee, Changeon [1 ,3 ]
机构
[1] Inha Univ, Dept Mech Engn, Inchon, South Korea
[2] Inha Univ, Korea Initiat Fostering Univ Res & Innovat, Incheon, South Korea
[3] 100 Inha Ro, Incheon 22212, South Korea
关键词
Condensing boiler; Waste-heat-recovery; Water injection; Thermal efficiency; Nitrogen oxides (NOx); EXHAUST-GAS RECIRCULATION; COMBUSTION CHARACTERISTICS; THERMAL EFFICIENCY; IMPROVEMENT;
D O I
10.1016/j.heliyon.2023.e19417
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The waste-heat-recovery boiler with water injection (HR-B/W) applies the heat exchange between the intake air and exhaust gas with the water injection into the intake air. Previous theoretical studies have discussed that the HR-B/W would increase the thermal efficiency of the boiler by the active heat exchange between the intake air and exhaust gas. It has also been discussed that the increased fraction of water vapor in the air would reduce the flame temperature which in turn decreases the NOx emission. However, the potential performance of the HR-B/W has not been validated through practical boiler tests by considering the evaporation characteristics of the injected water, which plays a critical role in the performance of the HR-B/W. In this study the effects of water injection into the intake air on the thermal efficiency and pollutant emissions of the waste-heat-recovery boiler are investigated using a commercial 24 kW condensing boiler in full load condition. Thermodynamic analysis is performed to evaluate the adequate amount of water injection and trace the physical properties in the boiler upon the water injection amount and evaporation characteristics. The boiler test results showed water injection can increase thermal efficiency to 4.4% point and reduce NOx and CO emissions by 69% and 33% respectively compared to those without water injection. These advantages can be further enhanced if the atomization and evaporation performance of injected water is improved.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Study on waste heat boiler ash deposition characteristics in sensible heat recovery process of converter gas
    Ni W.
    Zhao J.
    Li B.
    Wei X.
    Wu D.
    Liu D.
    Wang Q.
    Huagong Xuebao/CIESC Journal, 2023, 74 (08): : 3485 - 3493
  • [22] CHLORINATED WASTE INCINERATOR HEAT-RECOVERY BOILER CORROSION
    FORT, WC
    DICKS, LWR
    MATERIALS PERFORMANCE, 1986, 25 (03) : 9 - 14
  • [23] Analysis of failures in boiler tubes due to fireside corrosion in a waste heat recovery boiler
    Srikanth, S
    Ravikumar, B
    Das, SK
    Gopalakrishna, K
    Nandakumar, K
    Vijayan, P
    ENGINEERING FAILURE ANALYSIS, 2003, 10 (01) : 59 - 66
  • [24] A Study on Waste Heat Recovery in Drain Water with Water-to-water Heat Exchanger in Barbershops
    Sun, Fangtian
    Wang, Na
    Gong, Xiaogang
    Fan, Yunze
    Li, Deying
    PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 1231 - +
  • [25] Theoretical and experimental study on total heat recovery of condensing gas boiler flue gas by gas engine-driven compression heat pump
    Wu, Hubiao
    Zhao, Dongfang
    Liu, Fengguo
    Wu, De
    Cui, Zhaozhao
    APPLIED THERMAL ENGINEERING, 2024, 250
  • [26] Hydrodynamic characteristic research of water in waste heat boiler
    Tang, Qiang
    Zhang, Li
    Xiandai Huagong/Modern Chemical Industry, 2006, 26 (SUPPL.): : 284 - 288
  • [27] WASTE HEAT RECOVERY BOILER USES PROVEN HEAT PIPE TECHNOLOGY.
    Anon
    1600, (07):
  • [28] Experimental study of a waste heat recovery system for supplemental heaters
    Tanbour, E. Y.
    Al-Waked, R.
    Alzoubi, M. F.
    ENERGY AND SUSTAINABILITY III, 2011, 143 : 437 - 448
  • [29] An experimental study of waste heat recovery from a residential refrigerator
    Clark, RA
    Smith, RN
    Jensen, MK
    IECEC 96 - PROCEEDINGS OF THE 31ST INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE, VOLS 1-4, 1996, : 1887 - 1892
  • [30] An experimental study of smelt-water interaction in the recovery boiler dissolving tank
    Jin, Eric
    Bussmann, Markus
    Tran, Honghi
    TAPPI JOURNAL, 2015, 14 (06): : 385 - 393