Simple and rapid determination of clonidine in pharmaceutical samples by voltammetry using a bare glassy carbon electrode

被引:2
|
作者
Moreira, Debora A. R. [1 ]
Pimentel, Dilton M. [1 ]
Arrieiro, Mariane O. B. [1 ]
Barbosa, Sandro L. [2 ]
da Silva, Rodrigo A. B. [3 ]
dos Santos, Wallans T. P. [2 ]
机构
[1] Univ Fed Vales Jequitinhonha & Mucuri UFVJM, Dept Quim, Rodovia MGT 367,Km 583,5000 Alto Jacuba, BR-39100000 Diamantina, MG, Brazil
[2] Univ Fed Vales Jequitinhonha & Mucuri UFVJM, Dept Farm, Rodovia MGT 367,Km 583,5000 Alto Jacuba, BR-39100000 Diamantina, MG, Brazil
[3] Univ Fed Uberlandia, Inst Quim, Rodovia LMG 746,Km 1, BR-38500000 Monte Carmelo, MG, Brazil
关键词
clonidine; differential pulse voltammetry; glassy carbon electrode; narrow therapeutic index drugs; unmodified electrode; ELECTROCHEMICAL DETERMINATION; LIQUID-CHROMATOGRAPHY; INJECTION-ANALYSIS; PHENETHYLAMINES; ACID;
D O I
10.1002/elan.202200213
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents, for the first time, the voltammetric behavior of clonidine (CLO) drug and its determination, using an unmodified glassy carbon electrode (GCE). CLO exhibited only an irreversible oxidation process on the GCE, with peak potential at +0.85 V in pH 12 (vs Ag/AgCl). CLO oxidation process is pH-dependent and the electrochemical mechanisms on the GCE were proposed in acidic and basic medium. The determination of CLO was optimized in 0.1 mol L-1 phosphate buffer solution at pH 12.0 using differential pulse voltammetry (DPV), which provides a good linear range (0.65 to 106.00 mu mol L-1) and low theoretical limit of detection (0.14 mu mol L-1) for the quality control of this drug in pharmaceutical samples. In addition, stable responses of CLO at the GCE were obtained in the same day (RSD = 3.4 %; n = 5) and different days (RSD = 2.0 %; n = 3). Moreover, the determination of CLO in a pharmaceutical formulation using the proposed GCE-DPV method presented good accuracy, since the recovery was close to 100 % and the dosing result was in agreement with an official method (HPLC-UV). The proposed method demonstrates a good analytical performance for CLO determination in pharmaceutical samples, providing a faster, simpler and lower-cost alternative for quality control of CLO than other reported methods.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] The Determination of Dopamine Using Glassy Carbon Electrode Pretreated by a Simple Electrochemical Method
    Huang, De-Qian
    Chen, Cheng
    Wu, Yi-Ming
    Zhang, Hong
    Sheng, Liang-Quan
    Xu, Hua-Jie
    Liu, Zhao-Di
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (06): : 5510 - 5520
  • [42] Determination of tetracycline residue in pork by differential pulse voltammetry using activated glassy carbon electrode
    Huong, Nguyen Thu
    Hien, Nguyen Thi Minh
    Thuy, Tran Thi Diem
    Ai, Nguyen Thi Ngoc
    Anh, Le Diep Quoc
    VIETNAM JOURNAL OF CHEMISTRY, 2023, 61 (01) : 65 - 73
  • [43] A differential pulse voltammetric determination of nisoldipine using glassy carbon electrode in pharmaceutical preparations
    Dogrukol-Ak, D
    Gökören, N
    Tunçel, M
    ANALYTICAL LETTERS, 1998, 31 (01) : 105 - 116
  • [44] Determination of copper by anodic stripping voltammetry on a glassy carbon electrode using a continuous flow system
    vanStaden, JF
    Matoetoe, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (06): : 624 - 628
  • [45] Determination of copper by anodic stripping voltammetry on a glassy carbon electrode using a continuous flow system
    J. F. van Staden
    M. Matoetoe
    Fresenius' Journal of Analytical Chemistry, 1997, 357 : 624 - 628
  • [46] The determination of uric acid in human body fluid samples using glassy carbon electrode activated by a simple electrochemical method
    Deqian Huang
    Yang Cheng
    Haiyan Xu
    Hong Zhang
    Liangquan Sheng
    Huajie Xu
    Zhaodi Liu
    Hai Wu
    Suhua Fan
    Journal of Solid State Electrochemistry, 2015, 19 : 435 - 443
  • [47] The determination of uric acid in human body fluid samples using glassy carbon electrode activated by a simple electrochemical method
    Huang, Deqian
    Cheng, Yang
    Xu, Haiyan
    Zhang, Hong
    Sheng, Liangquan
    Xu, Huajie
    Liu, Zhaodi
    Wu, Hai
    Fan, Suhua
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2015, 19 (02) : 435 - 443
  • [48] Rapid and accurate amperometric determination of acetaminophen in pharmaceutical preparations and spiked human blood serum samples at cadmium pentacyanonitrosylferrate modified glassy carbon electrode
    Razmi, H.
    Harasi, M.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2008, 5 (02) : 296 - 305
  • [49] Determination of linuron in water and vegetable samples using stripping voltammetry with a carbon paste electrode
    de Lima, F.
    Cozzi, F.
    Fiorucci, A. R.
    Cardoso, C. A. L.
    Arruda, G. J.
    Ferreira, V. S.
    TALANTA, 2011, 83 (05) : 1763 - 1768
  • [50] Rapid and accurate amperometric determination of acetaminophen in pharmaceutical preparations and spiked human blood serum samples at cadmium pentacyanonitrosylferrate modified glassy carbon electrode
    H. Razmi
    M. Harasi
    Journal of the Iranian Chemical Society, 2008, 5 : 296 - 305