The Determination of Dopamine Using Glassy Carbon Electrode Pretreated by a Simple Electrochemical Method

被引:0
|
作者
Huang, De-Qian [1 ,2 ]
Chen, Cheng [1 ,2 ]
Wu, Yi-Ming [1 ,2 ]
Zhang, Hong [1 ,2 ]
Sheng, Liang-Quan [1 ,2 ]
Xu, Hua-Jie [1 ,2 ]
Liu, Zhao-Di [1 ,2 ]
机构
[1] Fuyang Teachers Coll, Sch Chem & Chem Engn, Fuyang 236041, Anhui, Peoples R China
[2] Anhui Prov Key Lab Degradat & Monitoring Pollut E, Fuyang 236041, Anhui, Peoples R China
来源
关键词
Pretreated GCE; cyclic voltammetry; dopamine; determination; SIMULTANEOUS VOLTAMMETRIC DETECTION; SELF-ASSEMBLED MONOLAYER; ASCORBIC-ACID; PASTE ELECTRODE; URIC-ACID; SELECTIVE DETERMINATION; SENSITIVE DETERMINATION; BEHAVIOR; OXIDATION; SENSOR;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this study, the pretreated glassy carbon electrode (GCE) was prepared by electrochemical oxidation firstly at +1.75 V for 300 s, and then by electrochemical reduction at -1.75 V for 300 s in 0.1 mol L-1 pH 7.0 phosphate buffer solution (PBS) and used for the determination of dopamine (DA) by cyclic voltammetry (CV). The pretreated GCE gives 100-fold greater current responses for dopamine compared with unpretreated GCE. The effect of pH, pretreated mode, scan rate and concentration of dopamine on the peak current was investigated, and the results indicated that the peak current of dopamine is the highest in 0.1 mol L-1 pH 7.0 PBS and the electrode reaction corresponds to a rate-controlled process. The peak current of the anodic peak and the concentration of dopamine hydrochloride is linear in the range of 1.0 x 10(-7) - 9.0 x 10(-6) mol L-1 and 1.2 x 10(-5) - 8.0 x 10(-5) mol L-1 with correlation coefficients of 0.9973 and 0.9980, and the detection limit is 3.0 x 10(-8) mol/L. It has been successfully applied to the determination of dopamine in dopamine hydrochloride injection with recoveries ranging from 98 to 103%. The proposed method possesses the distinct advantages of simple, appropriate for operation, good reproducibility and cheap instrument.
引用
收藏
页码:5510 / 5520
页数:11
相关论文
共 50 条
  • [1] ELECTROCHEMICAL DETERMINATION OF CHLORPROMAZINE BY ANODICALLY PRETREATED GLASSY-CARBON ELECTRODE
    TAKAMURA, K
    INOUE, S
    KUSU, F
    BUNSEKI KAGAKU, 1984, 33 (04) : 198 - 203
  • [2] Electrochemical behavior and voltammetric determination of epinephrine by different pretreated glassy carbon electrode
    Li, Zhiguo
    Hu, Yanfei
    Liu, Yuge
    Jia, Yongmei
    Ye, Cui
    Zhang, Lingling
    Chinese Journal of Analysis Laboratory, 2022, 41 (08) : 920 - 924
  • [3] Electrochemical detection of dopamine using a modified glassy carbon electrode
    Correa, Jaime
    Wang, Tingting
    Heineman, William R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [4] Simultaneous electrochemical determination of dopamine and acetaminophen using multiwall carbon nanotubes modified glassy carbon electrode
    Alothman, Zeid Abdullah
    Bukhari, Nausheen
    Wabaidur, Saikh Mohammad
    Haider, Sajjad
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (01): : 314 - 320
  • [5] Electrochemical Determination of Trace Promethazine Hydrochloride by a Pretreated Glassy Carbon Electrode Modified with DNA
    Zhou-Sheng Yang
    Jun Zhao
    Da-Peng Zhang
    Yun-Chun Liu
    Analytical Sciences, 2007, 23 : 569 - 572
  • [6] Electrochemical determination of trace promethazine hydrochloride by a pretreated glassy carbon electrode modified with DNA
    Yang, Zhou-Sheng
    Zhao, Jun
    Zhang, Da-Peng
    Liu, Yun-Chun
    ANALYTICAL SCIENCES, 2007, 23 (05) : 569 - 572
  • [7] Selective determination of dopamine with an amperometric biosensor using electrochemically pretreated and activated carbon/tyrosinase/NafionA®-modified glassy carbon electrode
    Rahman, Siti Fauziyah
    Min, Kyoungseon
    Park, Seok-Hwan
    Park, Jae-Hee
    Yoo, Jin Cheol
    Park, Don-Hee
    BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2016, 21 (05) : 627 - 633
  • [8] Selective determination of dopamine with an amperometric biosensor using electrochemically pretreated and activated carbon/tyrosinase/Nafion®-modified glassy carbon electrode
    Siti Fauziyah Rahman
    Kyoungseon Min
    Seok-Hwan Park
    Jae-Hee Park
    Jin Cheol Yoo
    Don-Hee Park
    Biotechnology and Bioprocess Engineering, 2016, 21 : 627 - 633
  • [9] The determination of uric acid in human body fluid samples using glassy carbon electrode activated by a simple electrochemical method
    Deqian Huang
    Yang Cheng
    Haiyan Xu
    Hong Zhang
    Liangquan Sheng
    Huajie Xu
    Zhaodi Liu
    Hai Wu
    Suhua Fan
    Journal of Solid State Electrochemistry, 2015, 19 : 435 - 443
  • [10] Simple, Rapid and Sensitive Electrochemical Method for the Determination of the Triketone Herbicide Sulcotrione in River Water Using a Glassy Carbon Electrode
    Stankovic, Dalibor M.
    Mehmeti, Eda
    Svorc, Lubomir
    Kalcher, Kurt
    ELECTROANALYSIS, 2015, 27 (07) : 1587 - 1593