Optimizing PCM Integrated Wall and Roof for Energy Saving in Building under Various Climatic Conditions of Mediterranean Region

被引:20
|
作者
Dardouri, Sana [1 ]
Tuncbilek, Ekrem [2 ,3 ]
Khaldi, Othmen [4 ]
Arici, Muslum [2 ,3 ]
Sghaier, Jalila [1 ]
机构
[1] Univ Monastir, Natl Engn Sch Monastir, Res Lab Thermal & Thermodynam Ind Proc LRTTPI, Monastir 5000, Tunisia
[2] Kocaeli Univ, Engn Fac, Mech Engn Dept, Umuttepe Campus, TR-41001 Kocaeli, Turkiye
[3] Kocaeli Univ, Int Joint Lab Low Carbon & New Energy Nexus Res &, TR-41001 Kocaeli, Turkiye
[4] Univ Tunis El Manar, Lab Mat Org & Properties LMOP LR99ES17, Tunis 2092, Tunisia
关键词
phase change materials; building performance; climatic condition; PCM melting temperature; CO2; reduction; PCM double layer; THERMAL STORAGE; OPTIMIZATION; PERFORMANCE; SYSTEM; CLASSIFICATION; MANAGEMENT; EFFICIENCY;
D O I
10.3390/buildings13030806
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Energy conservation in buildings has been the focus of many studies since nearly one-third of global energy consumption is due to buildings. Phase change material (PCM) technology promises to be an attractive solution for energy saving in buildings since it is a passive and effective technology, as demonstrated in the literature. Therefore, this study focuses on the energy-saving performance of PCM-integrated buildings located in a Mediterranean climate to reveal their energy-saving potential. PCM is integrated both in external or internal south walls and roofs of buildings under four different climatic conditions. EnergyPlus, which is a well-known building simulation software, is adopted for building thermal analyses. The effects of melting temperature, location of PCM layer in the wall, thickness of PCM layer, type of envelope (wall or roof), and PCM double-layer system in the wall are investigated. The corresponding energy savings and CO2 emission reductions are obtained for the considered cases. The results showed that up to 41.6% reduction in energy demand can be obtained depending on the PCM application. Besides, PCM with a low melting temperature (21 degrees C) favored heating energy savings, while PCM with a high melting temperature (29 degrees C) favored cooling energy savings. Moreover, the double-layer PCM system provided higher energy savings than the single-layer PCM system, especially in warm and arid regions (Sousse and Tozeur).
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Study of Various Glass Window and Building Wall Materials in Different Climatic Zones of India for Energy Efficient Building Construction
    Kumar, G. Kiran
    Saboor, S.
    Babu, T. P. Ashok
    2017 INTERNATIONAL CONFERENCE ON ALTERNATIVE ENERGY IN DEVELOPING COUNTRIES AND EMERGING ECONOMIES, 2017, 138 : 580 - 585
  • [32] Energy and indoor thermal performance analysis of a glazed facade high-rise building under various Nordic climatic conditions
    Bhattacharjee, Shimantika
    Lidelow, Sofia
    Shadram, Farshid
    ENERGY REPORTS, 2023, 10 : 3039 - 3053
  • [33] ENERGY-SAVING BUILDING PROGRAM EVALUATION WITH AN INTEGRATED METHOD UNDER LINGUISTIC ENVIRONMENT
    Huang, Min
    Zhang, Xinli
    Ren, Ruxue
    Liao, Huchang
    Zavadskas, Edmundas Kazimieras
    Antucheviciene, Jurgita
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2020, 26 (05) : 447 - 458
  • [34] Technical Suitability of Energy Saving Scheme for Optimizing the Thermal Insulation Layer Thickness of Residential Building Exterior Wall
    Shen, Tianqing
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2022, 40 (06) : 1366 - 1375
  • [35] Improved energy-saving performance of a small office building using coupled phase change materials and thermochromic (PCM/TC) roof system
    Sun, Lingfan
    Gui, Lin
    Cheng, Hongbo
    JOURNAL OF ENERGY STORAGE, 2024, 100
  • [36] Energy-saving of building envelope using passive PCM technique: A case study of Kuwait City climate conditions
    Al-Rashed, Abdullah A. A. A.
    Alnaqi, Abdulwahab A.
    Alsarraf, Jalal
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 46
  • [37] Thermodynamic analysis of the effect of mass transfer on a real building wall efficiency under climatic transient conditions
    Berger, Julien
    Ferrasse, Jean -Henry
    Gasparin, Suelen
    Le Metayer, Olivier
    Kadoch, Benjamin
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 202
  • [38] Energy assessment, economic analysis, and environmental study of an Iranian building: The effect of wall materials and climatic conditions
    Sadati, Seyed Esmaeil
    Rahbar, Nader
    Kargarsharifabad, Hadi
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2023, 56
  • [39] Energy saving potential of a ventilation system with a latent heat thermal energy storage unit under different climatic conditions
    Chen, Xiaoming
    Zhang, Quan
    Zhai, Zhiqiang
    ENERGY AND BUILDINGS, 2016, 118 : 339 - 349
  • [40] Yield and quality response of drip-irrigated pepper under Mediterranean climatic conditions to various water regimes
    Sezen, S. Metin
    Yazar, Attila
    Tekin, Servet
    Eker, Salim
    Kapur, Burcak
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (08): : 1329 - 1339