Optimizing PCM Integrated Wall and Roof for Energy Saving in Building under Various Climatic Conditions of Mediterranean Region

被引:20
|
作者
Dardouri, Sana [1 ]
Tuncbilek, Ekrem [2 ,3 ]
Khaldi, Othmen [4 ]
Arici, Muslum [2 ,3 ]
Sghaier, Jalila [1 ]
机构
[1] Univ Monastir, Natl Engn Sch Monastir, Res Lab Thermal & Thermodynam Ind Proc LRTTPI, Monastir 5000, Tunisia
[2] Kocaeli Univ, Engn Fac, Mech Engn Dept, Umuttepe Campus, TR-41001 Kocaeli, Turkiye
[3] Kocaeli Univ, Int Joint Lab Low Carbon & New Energy Nexus Res &, TR-41001 Kocaeli, Turkiye
[4] Univ Tunis El Manar, Lab Mat Org & Properties LMOP LR99ES17, Tunis 2092, Tunisia
关键词
phase change materials; building performance; climatic condition; PCM melting temperature; CO2; reduction; PCM double layer; THERMAL STORAGE; OPTIMIZATION; PERFORMANCE; SYSTEM; CLASSIFICATION; MANAGEMENT; EFFICIENCY;
D O I
10.3390/buildings13030806
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Energy conservation in buildings has been the focus of many studies since nearly one-third of global energy consumption is due to buildings. Phase change material (PCM) technology promises to be an attractive solution for energy saving in buildings since it is a passive and effective technology, as demonstrated in the literature. Therefore, this study focuses on the energy-saving performance of PCM-integrated buildings located in a Mediterranean climate to reveal their energy-saving potential. PCM is integrated both in external or internal south walls and roofs of buildings under four different climatic conditions. EnergyPlus, which is a well-known building simulation software, is adopted for building thermal analyses. The effects of melting temperature, location of PCM layer in the wall, thickness of PCM layer, type of envelope (wall or roof), and PCM double-layer system in the wall are investigated. The corresponding energy savings and CO2 emission reductions are obtained for the considered cases. The results showed that up to 41.6% reduction in energy demand can be obtained depending on the PCM application. Besides, PCM with a low melting temperature (21 degrees C) favored heating energy savings, while PCM with a high melting temperature (29 degrees C) favored cooling energy savings. Moreover, the double-layer PCM system provided higher energy savings than the single-layer PCM system, especially in warm and arid regions (Sousse and Tozeur).
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Energy analysis of the building integrated with a double PCM wallboard system in various climate regions of Iran
    Refahi, Amirhossein
    Rostami, Abolfazl
    Amani, Mohammad
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2023, 148 (16) : 7981 - 7993
  • [22] Energy analysis of the building integrated with a double PCM wallboard system in various climate regions of Iran
    Amirhossein Refahi
    Abolfazl Rostami
    Mohammad Amani
    Journal of Thermal Analysis and Calorimetry, 2023, 148 : 7981 - 7993
  • [23] Dynamic analysis of daylight metrics and energy saving for rooftop window integrated flat roof structure of building
    Sudan, Madhu
    Tiwari, G. N.
    Al-Helal, I. M.
    SOLAR ENERGY, 2015, 122 : 834 - 846
  • [24] Machine learning-based predicting of PCM-integrated building thermal performance: An application under various weather conditions in Morocco
    Jraida, Kaoutar
    EL Mghouchi, Youness
    Mourid, Amina
    Haidar, Chadia
    EL Alami, Mustapha
    JOURNAL OF BUILDING ENGINEERING, 2024, 96
  • [25] Energy and economic performance of green roof system under future climatic conditions in Hong Kong
    Chan, A. L. S.
    Chow, T. T.
    ENERGY AND BUILDINGS, 2013, 64 : 182 - 198
  • [26] Evaluation of the energy performance for a nZEB office building under specific climatic conditions
    Bajenaru, Nicolae
    Damian, Andrei
    Frunzulica, Rodica
    EENVIRO-YRC 2015 - BUCHAREST, 2016, 85 : 26 - 34
  • [27] The Energy Saving Potential of Wide Windows in Hospital Patient Rooms, Optimizing the Type of Glazing and Lighting Control Strategy under Different Climatic Conditions
    Cesari, Silvia
    Valdiserri, Paolo
    Coccagna, Maddalena
    Mazzacane, Sante
    ENERGIES, 2020, 13 (08)
  • [28] Optimizing the thermal performance of building envelopes for energy saving in underground office buildings in various climates of China
    Shi, Luyang
    Zhang, Huibo
    Li, Zongxin
    Luo, Zhiwen
    Liu, Jing
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 77 : 26 - 35
  • [29] Roof-integrated radiative air-cooling system to achieve cooler attic for building energy saving
    Zhao, Dongliang
    Aili, Ablimit
    Yin, Xiaobo
    Tan, Gang
    Yang, Ronggui
    ENERGY AND BUILDINGS, 2019, 203
  • [30] Energy -saving potential of 3D printed concrete building with integrated living wall
    He, Yawen
    Zhang, Yamei
    Zhang, Chao
    Zhou, Hongyu
    ENERGY AND BUILDINGS, 2020, 222