Optimizing PCM Integrated Wall and Roof for Energy Saving in Building under Various Climatic Conditions of Mediterranean Region

被引:20
|
作者
Dardouri, Sana [1 ]
Tuncbilek, Ekrem [2 ,3 ]
Khaldi, Othmen [4 ]
Arici, Muslum [2 ,3 ]
Sghaier, Jalila [1 ]
机构
[1] Univ Monastir, Natl Engn Sch Monastir, Res Lab Thermal & Thermodynam Ind Proc LRTTPI, Monastir 5000, Tunisia
[2] Kocaeli Univ, Engn Fac, Mech Engn Dept, Umuttepe Campus, TR-41001 Kocaeli, Turkiye
[3] Kocaeli Univ, Int Joint Lab Low Carbon & New Energy Nexus Res &, TR-41001 Kocaeli, Turkiye
[4] Univ Tunis El Manar, Lab Mat Org & Properties LMOP LR99ES17, Tunis 2092, Tunisia
关键词
phase change materials; building performance; climatic condition; PCM melting temperature; CO2; reduction; PCM double layer; THERMAL STORAGE; OPTIMIZATION; PERFORMANCE; SYSTEM; CLASSIFICATION; MANAGEMENT; EFFICIENCY;
D O I
10.3390/buildings13030806
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Energy conservation in buildings has been the focus of many studies since nearly one-third of global energy consumption is due to buildings. Phase change material (PCM) technology promises to be an attractive solution for energy saving in buildings since it is a passive and effective technology, as demonstrated in the literature. Therefore, this study focuses on the energy-saving performance of PCM-integrated buildings located in a Mediterranean climate to reveal their energy-saving potential. PCM is integrated both in external or internal south walls and roofs of buildings under four different climatic conditions. EnergyPlus, which is a well-known building simulation software, is adopted for building thermal analyses. The effects of melting temperature, location of PCM layer in the wall, thickness of PCM layer, type of envelope (wall or roof), and PCM double-layer system in the wall are investigated. The corresponding energy savings and CO2 emission reductions are obtained for the considered cases. The results showed that up to 41.6% reduction in energy demand can be obtained depending on the PCM application. Besides, PCM with a low melting temperature (21 degrees C) favored heating energy savings, while PCM with a high melting temperature (29 degrees C) favored cooling energy savings. Moreover, the double-layer PCM system provided higher energy savings than the single-layer PCM system, especially in warm and arid regions (Sousse and Tozeur).
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Seasonal and annual performance analysis of PCM-integrated building brick under the climatic conditions of Marmara region
    Ekrem Tunçbilek
    Müslüm Arıcı
    Salwa Bouadila
    Surjamanto Wonorahardjo
    Journal of Thermal Analysis and Calorimetry, 2020, 141 : 613 - 624
  • [2] Seasonal and annual performance analysis of PCM-integrated building brick under the climatic conditions of Marmara region
    Tuncbilek, Ekrem
    Arici, Muslum
    Bouadila, Salwa
    Wonorahardjo, Surjamanto
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 141 (01) : 613 - 624
  • [3] Optimizing the energy and exergy of building integrated photovoltaic thermal (BIPVT) systems under cold climatic conditions
    Agrawal, Basant
    Tiwari, G. N.
    APPLIED ENERGY, 2010, 87 (02) : 417 - 426
  • [4] An assessment of reducing energy consumption for optimizing building design in various climatic conditions
    Fazelpour, Farivar
    Bakhshayesh, Ali
    Alimohammadi, Reza
    Saraei, Alireza
    INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENTAL ENGINEERING, 2022, 13 (01) : 319 - 329
  • [5] An assessment of reducing energy consumption for optimizing building design in various climatic conditions
    Farivar Fazelpour
    Ali Bakhshayesh
    Reza Alimohammadi
    Alireza Saraei
    International Journal of Energy and Environmental Engineering, 2022, 13 : 319 - 329
  • [6] Analysis of Energy Saving Potential in High-Performance Building Technologies under Korean Climatic Conditions
    Kim, Chul-Ho
    Lee, Seung-Eon
    Kim, Kang-Soo
    ENERGIES, 2018, 11 (04)
  • [7] Sustainable and energy saving urban horticulture on rooftop gardens in Mediterranean climatic conditions
    Di Bonito, R.
    Biagiotti, D.
    Giagnacovo, G.
    Viola, C.
    Campiotti, C. A.
    INTERNATIONAL SYMPOSIUM ON GREENER CITIES FOR MORE EFFICIENT ECOSYSTEM SERVICES IN A CLIMATE CHANGING WORLD, 2018, 1215 : 383 - 388
  • [8] Building Energy Flexibility Assessment in Mediterranean Climatic Conditions: The Case of a Greek Office Building
    Chantzis, Georgios
    Giama, Effrosyni
    Papadopoulos, Agis M.
    APPLIED SCIENCES-BASEL, 2023, 13 (12):
  • [9] Changing Energy Requirements in the Mediterranean Under Changing Climatic Conditions
    Giannakopoulos, Christos
    Hadjinicolaou, Panos
    Zerefos, Christos
    Demosthenous, George
    ENERGIES, 2009, 2 (04) : 805 - 815
  • [10] Implementation of ANN and GA on building with PCM at various setpoints, PCM types, and installation locations to boost energy saving and CO2 saving
    Abbasian-Naghneh, Salman
    Kalbasi, Rasool
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2022, 144 : 110 - 126