Outcomes of single-port robotic ureteral reconstruction using the da Vinci SP® system

被引:1
|
作者
Heo, Ji Eun [1 ]
Kang, Sung Ku [2 ]
Lee, Jongsoo [1 ]
Koh, Donghoon [3 ]
Kim, Min Seok [4 ]
Lee, Yong Seung [1 ]
Ham, Won Sik [1 ]
Jang, Won Sik [1 ,5 ]
机构
[1] Yonsei Univ, Urol Sci Inst, Dept Urol, Coll Med, Seoul, South Korea
[2] Natl Hlth Insurance Serv Ilsan Hosp, Dept Urol, Goyang, South Korea
[3] Konyang Univ, Dept Urol, Coll Med, Daejeon, South Korea
[4] Chosun Univ, Dept Urol, Sch Med, Gwangju, South Korea
[5] Yonsei Univ, Urol Sci Inst, Dept Urol, Coll Med, 50-1 Yonsei Ro, Seoul 03722, South Korea
关键词
Reconstructive surgical procedures; Robotic surgical procedures; Ureter; Ureteral obstruction; ASSISTED PYELOPLASTY; SITE SURGERY; REIMPLANTATION;
D O I
10.4111/icu.20230005
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The da Vinci SP & REG; robotic system enables three double-jointed wristed instruments and a fully wristed three-dimensional camera to be placed through a single port. This study presents our experience with robot-assisted ureteral reconstruction using the SP system and reports its outcomes. Materials and Methods: Between December 2018 and April 2022, a single surgeon performed robotic ureteral reconstruction using the SP system in 39 patients: 18 underwent pyeloplasty and 21 received ureteral reimplantation. Demographic and perioperative patient data were collected and analyzed. Radiographic and symptomatic improvements were assessed 3 months after surgery. Results: In pyeloplasty group, 12 patients (66.7%) were female and two patients (11.1%) had undergone previous surgery for ureteral obstruction. The median operative time was 152 minutes, the median blood loss was 8 mL, and the median length of stay in hospital was 3 days. There was one case of a complication involving postoperative percutaneous nephrostomy (PCN). In ureteral reimplantation group, 19 patients (90.5%) were female and ten patients (47.6%) had undergone gynecological surgery that caused ureteral obstruction. The median operative time was 152 minutes, the median blood loss was 10 mL, and the median length of stay in hospital was 4 days. We observed one case of open conversion and two cases of complications (colonic serosal tearing and postoperative PCN after ileal ureter replacement). The radiographic results and symptoms successfully improved following both surgeries. Conclusions: Despite adhesion-related complications, the SP system appears to be safe and effective for use in robot-assisted ureteral reconstruction.
引用
收藏
页码:373 / 379
页数:7
相关论文
共 50 条
  • [31] Single-port (SP) robotic pancreatic surgery using the da Vinci SP system: A retrospective study on prospectively collected data in a consecutive patient cohort
    Liu, Rong
    Liu, Qu
    Zhao, Guodong
    Zhao, Zhiming
    Li, Mengyang
    Gao, Yuanxing
    INTERNATIONAL JOURNAL OF SURGERY, 2022, 104
  • [32] Compartmental Transoral Robotic Lateral Oropharyngectomy with the da Vinci Single-Port System: Surgical Technique
    De Virgilio, Armando
    Costantino, Andrea
    Festa, Bianca Maria
    Sampieri, Claudio
    Spriano, Giuseppe
    Kim, Se-Heon
    ANNALS OF SURGICAL ONCOLOGY, 2023, 30 (09) : 5728 - 5732
  • [33] Compartmental Transoral Robotic Lateral Oropharyngectomy with the da Vinci Single-Port System: Surgical Technique
    Armando De Virgilio
    Andrea Costantino
    Bianca Maria Festa
    Claudio Sampieri
    Giuseppe Spriano
    Se-Heon Kim
    Annals of Surgical Oncology, 2023, 30 : 5728 - 5732
  • [34] A Preclinical Feasibility Study of Single-Port Robotic Subcostal Anatomical Lung Resection and Subxiphoid Thymectomy Using the da Vinci(R) SP System
    Wu, Ching Feng
    Cheng, Chuan
    Suen, Ka Hei
    Stein, Hubert
    Chao, Yin Kai
    DIAGNOSTICS, 2023, 13 (03)
  • [35] A new hybrid robotic surgery by minimally invasive laparoscopic and robotic (MILAR) system using da Vinci single-port (SP) in distal gastrectomy for gastric cancer
    Yoshikawa, Takaki
    Hayashi, Tsutomu
    Nishino, Masashi
    Ogawa, Rei
    Fujisaki, Yurina
    Honda, Shunya
    Wada, Takeyuki
    Yamagata, Yukinori
    Seto, Yasuyuki
    ASIAN JOURNAL OF ENDOSCOPIC SURGERY, 2025, 18 (01)
  • [36] Comparing the Approach to Radical Prostatectomy Using the Multiport da Vinci Xi and Single-port da Vinci SP Robots: A Propensity Score Analysis of Perioperative Outcomes
    Moschovas, Marcio Covas
    Bhat, Seetharam
    Sandri, Marco
    Rogers, Travis
    Onol, Fikret
    Mazzone, Elio
    Roof, Shannon
    Mottrie, Alexandre
    Patel, Vipul
    EUROPEAN UROLOGY, 2021, 79 (03) : 393 - 404
  • [37] Single-port robotic-assisted laparoscopic sacrocolpopexy with magnetic retraction: first experience using the SP da Vinci platform
    Vishnu Ganesan
    Ramy Goueli
    Dayron Rodriguez
    Deborah Hess
    Maude Carmel
    Journal of Robotic Surgery, 2020, 14 : 753 - 758
  • [38] First human surgery with a novel single-port robotic system: cholecystectomy using the da Vinci Single-Site platform
    Matthew Kroh
    Kevin El-Hayek
    Steven Rosenblatt
    Bipan Chand
    Pedro Escobar
    Jihad Kaouk
    Sricharan Chalikonda
    Surgical Endoscopy, 2011, 25
  • [39] Single-port robotic totally extraperitoneal(TEP) inguinal hernia repair using the da Vinci SP platform: A video vignette
    Kim, Dongjun
    Lee, Chul Seung
    ASIAN JOURNAL OF SURGERY, 2022, 45 (10) : 2062 - 2063
  • [40] Single-port robotic-assisted laparoscopic sacrocolpopexy with magnetic retraction: first experience using the SP da Vinci platform
    Ganesan, Vishnu
    Goueli, Ramy
    Rodriguez, Dayron
    Hess, Deborah
    Carmel, Maude
    JOURNAL OF ROBOTIC SURGERY, 2020, 14 (05) : 753 - 758