Outcomes of single-port robotic ureteral reconstruction using the da Vinci SP® system

被引:1
|
作者
Heo, Ji Eun [1 ]
Kang, Sung Ku [2 ]
Lee, Jongsoo [1 ]
Koh, Donghoon [3 ]
Kim, Min Seok [4 ]
Lee, Yong Seung [1 ]
Ham, Won Sik [1 ]
Jang, Won Sik [1 ,5 ]
机构
[1] Yonsei Univ, Urol Sci Inst, Dept Urol, Coll Med, Seoul, South Korea
[2] Natl Hlth Insurance Serv Ilsan Hosp, Dept Urol, Goyang, South Korea
[3] Konyang Univ, Dept Urol, Coll Med, Daejeon, South Korea
[4] Chosun Univ, Dept Urol, Sch Med, Gwangju, South Korea
[5] Yonsei Univ, Urol Sci Inst, Dept Urol, Coll Med, 50-1 Yonsei Ro, Seoul 03722, South Korea
关键词
Reconstructive surgical procedures; Robotic surgical procedures; Ureter; Ureteral obstruction; ASSISTED PYELOPLASTY; SITE SURGERY; REIMPLANTATION;
D O I
10.4111/icu.20230005
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The da Vinci SP & REG; robotic system enables three double-jointed wristed instruments and a fully wristed three-dimensional camera to be placed through a single port. This study presents our experience with robot-assisted ureteral reconstruction using the SP system and reports its outcomes. Materials and Methods: Between December 2018 and April 2022, a single surgeon performed robotic ureteral reconstruction using the SP system in 39 patients: 18 underwent pyeloplasty and 21 received ureteral reimplantation. Demographic and perioperative patient data were collected and analyzed. Radiographic and symptomatic improvements were assessed 3 months after surgery. Results: In pyeloplasty group, 12 patients (66.7%) were female and two patients (11.1%) had undergone previous surgery for ureteral obstruction. The median operative time was 152 minutes, the median blood loss was 8 mL, and the median length of stay in hospital was 3 days. There was one case of a complication involving postoperative percutaneous nephrostomy (PCN). In ureteral reimplantation group, 19 patients (90.5%) were female and ten patients (47.6%) had undergone gynecological surgery that caused ureteral obstruction. The median operative time was 152 minutes, the median blood loss was 10 mL, and the median length of stay in hospital was 4 days. We observed one case of open conversion and two cases of complications (colonic serosal tearing and postoperative PCN after ileal ureter replacement). The radiographic results and symptoms successfully improved following both surgeries. Conclusions: Despite adhesion-related complications, the SP system appears to be safe and effective for use in robot-assisted ureteral reconstruction.
引用
收藏
页码:373 / 379
页数:7
相关论文
共 50 条
  • [21] Reproductive surgery for fertility preservation: Robotic single-port myomectomy (da Vinci® SP) versus robotic single-site myomectomy (da Vinci® Xi or Si)
    Jeong, K.
    Lee, J. H.
    Park, S. Y.
    Shin, W.
    Chung, H. W.
    HUMAN REPRODUCTION, 2024, 39 : I170 - I170
  • [22] ROBOT-ASSISTED LAPAROSCOPIC SINGLE-PORT PYELOPLASTY IN CHILDREN USING THE DA VINCI SP® SYSTEM
    Kang, Sungku
    Jang, Won Sik
    Kim, Sang Woon
    Hwang, Tae Hyun
    Han, Sang Won
    Lee, Yong Seung
    JOURNAL OF UROLOGY, 2020, 203 : E180 - E180
  • [23] Robotic Single-Port da Vinci Surgical System (SP1098) in Gynecologic Surgery: A Systematic Review of Literature
    Arcieri, Martina
    Romeo, Paola
    Vizzielli, Giuseppe
    Restaino, Stefano
    Driul, Lorenza
    Stabile, Guglielmo
    Granese, Roberta
    Cianci, Stefano
    Ercoli, Alfredo
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2023, 50 (08):
  • [24] Safety and feasibility of single-port surgery for posterior retroperitoneal adrenalectomy using the da Vinci SP robotic system: a retrospective cohort study
    Kim, Byung-Chang
    Kwon, Douk
    Pak, Shin Jeong
    Cho, Jae Won
    Kim, Won Woong
    Sung, Tae-Yon
    Chung, Ki-Wook
    Lee, Yu-mi
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2023, 37 (11): : 8269 - 8276
  • [25] Safety and feasibility of single-port surgery for posterior retroperitoneal adrenalectomy using the da Vinci SP robotic system: a retrospective cohort study
    Byung-Chang Kim
    Douk Kwon
    Shin Jeong Pak
    Jae Won Cho
    Won Woong Kim
    Tae-Yon Sung
    Ki-Wook Chung
    Yu-mi Lee
    Surgical Endoscopy, 2023, 37 (11) : 8269 - 8276
  • [26] INTRAOPERATIVE WORKLOAD DURING ROBOTIC RADICAL PROSTATECTOMY: COMPARISON BETWEEN MULTI-PORT DA VINCI XI AND SINGLE-PORT DA VINCI SP ROBOTS
    Aro-Lambo, Mazeed
    Hallbeck, Susan
    Law, Katherine
    Norasi, Hamid
    Tollefson, Matthew
    JOURNAL OF UROLOGY, 2022, 207 (05): : E985 - E986
  • [27] Da Vinci Single-Port (SP) robotic transverse colectomy for mid-transverse colon cancer
    Piozzi, G. N.
    Lee, D. Y.
    Kim, J. S.
    Kim, S. H.
    TECHNIQUES IN COLOPROCTOLOGY, 2022, 26 (08) : 681 - 682
  • [28] Da Vinci Single-Port (SP) robotic transverse colectomy for mid-transverse colon cancer
    G. N. Piozzi
    D. Y. Lee
    J. S. Kim
    S. H. Kim
    Techniques in Coloproctology, 2022, 26 : 681 - 682
  • [29] Single-port robotic intersphincteric resection for very low rectal cancer with the da Vinci SP platform
    Alshalawi, Wed
    Lee, Chul Seung
    Lee, Yoon Suk
    ASIAN JOURNAL OF SURGERY, 2023, 46 (02) : 1056 - 1057
  • [30] Single-port robot plus one port (SP+1) distal pancreatectomy using the new da Vinci SP system
    Choi, Yoo Jin
    Jo, Hye-Sung
    Kim, Dong-Sik
    Yu, Young-Dong
    LANGENBECKS ARCHIVES OF SURGERY, 2022, 407 (03) : 1271 - 1276