Outcomes of single-port robotic ureteral reconstruction using the da Vinci SP® system

被引:1
|
作者
Heo, Ji Eun [1 ]
Kang, Sung Ku [2 ]
Lee, Jongsoo [1 ]
Koh, Donghoon [3 ]
Kim, Min Seok [4 ]
Lee, Yong Seung [1 ]
Ham, Won Sik [1 ]
Jang, Won Sik [1 ,5 ]
机构
[1] Yonsei Univ, Urol Sci Inst, Dept Urol, Coll Med, Seoul, South Korea
[2] Natl Hlth Insurance Serv Ilsan Hosp, Dept Urol, Goyang, South Korea
[3] Konyang Univ, Dept Urol, Coll Med, Daejeon, South Korea
[4] Chosun Univ, Dept Urol, Sch Med, Gwangju, South Korea
[5] Yonsei Univ, Urol Sci Inst, Dept Urol, Coll Med, 50-1 Yonsei Ro, Seoul 03722, South Korea
关键词
Reconstructive surgical procedures; Robotic surgical procedures; Ureter; Ureteral obstruction; ASSISTED PYELOPLASTY; SITE SURGERY; REIMPLANTATION;
D O I
10.4111/icu.20230005
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The da Vinci SP & REG; robotic system enables three double-jointed wristed instruments and a fully wristed three-dimensional camera to be placed through a single port. This study presents our experience with robot-assisted ureteral reconstruction using the SP system and reports its outcomes. Materials and Methods: Between December 2018 and April 2022, a single surgeon performed robotic ureteral reconstruction using the SP system in 39 patients: 18 underwent pyeloplasty and 21 received ureteral reimplantation. Demographic and perioperative patient data were collected and analyzed. Radiographic and symptomatic improvements were assessed 3 months after surgery. Results: In pyeloplasty group, 12 patients (66.7%) were female and two patients (11.1%) had undergone previous surgery for ureteral obstruction. The median operative time was 152 minutes, the median blood loss was 8 mL, and the median length of stay in hospital was 3 days. There was one case of a complication involving postoperative percutaneous nephrostomy (PCN). In ureteral reimplantation group, 19 patients (90.5%) were female and ten patients (47.6%) had undergone gynecological surgery that caused ureteral obstruction. The median operative time was 152 minutes, the median blood loss was 10 mL, and the median length of stay in hospital was 4 days. We observed one case of open conversion and two cases of complications (colonic serosal tearing and postoperative PCN after ileal ureter replacement). The radiographic results and symptoms successfully improved following both surgeries. Conclusions: Despite adhesion-related complications, the SP system appears to be safe and effective for use in robot-assisted ureteral reconstruction.
引用
收藏
页码:373 / 379
页数:7
相关论文
共 50 条
  • [1] Robotic Single-Port Donor Nephrectomy with the da Vinci SP® Surgical System
    Garden, Evan B.
    Al-Alao, Osama
    Razdan, Shirin
    Mullen, Gregory R.
    Florman, Sander
    Palese, Michael A.
    JSLS-JOURNAL OF THE SOCIETY OF LAPAROENDOSCOPIC SURGEONS, 2021, 25 (04)
  • [2] Robotic single-port myomectomy using the da Vinci SP surgical system: A pilot study
    Lee, Jung Hun
    Yoo, Hae Kyung
    Park, So Yun
    Moon, Hye-Sung
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2022, 48 (01) : 200 - 206
  • [3] Technique and perioperative outcomes of single-port robotic surgery using the da Vinci SP platform in urology
    Kim, Kwang Hyun
    Ahn, Hyun Kyu
    Kim, Myong
    Yoon, Hana
    ASIAN JOURNAL OF SURGERY, 2023, 46 (01) : 472 - 477
  • [4] Robotic Adrenalectomy Using the da Vinci SP Robotic System: Technical Feasibility Comparison with Single-Port Access Using the da Vinci Multi-arm Robotic System
    In A Lee
    Jin Kyong Kim
    Kwangsoon Kim
    Sang-Wook Kang
    Jandee Lee
    Jong Ju Jeong
    Kee-Hyun Nam
    Woong Youn Chung
    Annals of Surgical Oncology, 2022, 29 : 3085 - 3092
  • [5] Robotic Adrenalectomy Using the da Vinci SP Robotic System: Technical Feasibility Comparison with Single-Port Access Using the da Vinci Multi-arm Robotic System
    Lee, In A.
    Kim, Jin Kyong
    Kim, Kwangsoon
    Kang, Sang-Wook
    Lee, Jandee
    Jeong, Jong Ju
    Nam, Kee-Hyun
    Chung, Woong Youn
    ANNALS OF SURGICAL ONCOLOGY, 2022, 29 (05) : 3085 - 3092
  • [6] Feasibility and Efficacy of Single-Port Robotic Cholecystectomy Using the da Vinci SP® Platform
    Kim, Wan-Joon
    Choi, Sae-Byeol
    Kim, Wan-Bae
    JSLS-JOURNAL OF THE SOCIETY OF LAPAROENDOSCOPIC SURGEONS, 2022, 26 (02)
  • [7] Single-port robotic surgery for mediastinal tumors using the da vinci SP system: Initial experience
    Yang, Bo
    Chen, Ruiji
    Lin, Yingxue
    Liu, Yang
    FRONTIERS IN SURGERY, 2022, 9
  • [9] Da Vinci Single-Port Robotic Radical Prostatectomy
    Covas Moschovas, Marcio
    Bhat, Seetharam
    Rogers, Travis
    Noel, Jonathan
    Reddy, Sunil
    Patel, Vipul
    JOURNAL OF ENDOUROLOGY, 2021, 35 : S93 - S99
  • [10] Comparison of perioperative outcomes of single-port da Vinci SP and multiport da Vinci Xi robotic systems in robotic-assisted urologic surgeries
    Dennis, C.
    Morgantini, L. A.
    Zuberek, M.
    Francavilla, S.
    Trippel, R. S.
    Crivellaro, S.
    EUROPEAN UROLOGY, 2022, 81 : S33 - S34