Sleeveless guided implant placement compared to conventional approaches: An in vitro study at healed sites and fresh extraction sockets

被引:0
|
作者
Galli, Matthew [1 ]
Mendonca, Gustavo [2 ]
Meneghetti, Priscila [3 ]
Bekkali, Mariam [2 ]
Travan, Suncica [1 ]
Wang, Horn-Lay [1 ]
Li, Junying [1 ,4 ]
机构
[1] Univ Michigan, Dept Periodont & Oral Med, Sch Dent, Ann Arbor, MI USA
[2] Univ Michigan, Dept Biol & Mat Sci, Div Prosthodont, Sch Dent, Ann Arbor, MI USA
[3] Pontificial Catholic Univ Rio Grande, Porto Alegre, Brazil
[4] Univ Michigan, Biol & Mat Sci & Prosthodont, Sch Dent, 1011 N Univ Ave, Ann Arbor, MI 48109 USA
关键词
accuracy; computer-assisted; dental implants; guided surgery; immediate implant placement; PERI-IMPLANTITIS; SURGERY; ACCURACY; ABUTMENT; FREEHAND; ERRORS; RISKS;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To investigate the accuracy of a novel sleeveless implant surgical guide by comparing it with a conventional closed-sleeve guide and a freehand approach. Materials and methods: Custom resin maxillary casts with corticocancellous compartments were used (n = 30). Seven implant sites were present per maxillary cast, corresponding to healed (right and left first premolars, left second premolar and first molar) and extraction sites (right canine and central incisors). The casts were assigned into three groups: freehand (FH), conventional closed -sleeve guide (CG) and surgical guide (SG) groups. Each group comprised 10 casts and 70 implant sites (30 extraction sites and 40 healed sites). Digital planning was used to design 3D printed conventional and surgical guide templates. The primary study outcome was implant deviation. Results: At extraction sites, the largest difference between groups occurred in angular deviation, where the SG group (3.80 +/- 1.67 degrees) exhibited-1.6 times smaller deviation relative to the FH group (6.02 +/- 3.44 degrees; P=0.004). The CG group (0.69 +/- 0.40 mm) exhibited smaller coronal horizontal deviation compared to the SG group (1.08 +/- 0.54 mm; P=0.005). For healed sites, the largest difference occurred for angular deviation, where the SG group (2.31 +/- 1.30 degrees) exhibited 1.9 times smaller deviation relative to the CG group (4.42 +/- 1.51 degrees; P < 0.001), and 1.7 times smaller deviation relative to the FH group (3.84 +/- 2.14 degrees). Significant differences were found for all parameters except depth and coronal horizontal deviation. For the guided groups, there were fewer significant differences between healed and immediate sites compared to the FH group. Conclusion: The novel sleeveless surgical guide showed similar accuracy to the conventional closed-sleeve guide.
引用
收藏
页码:117 / 132
页数:16
相关论文
共 50 条
  • [31] Influence of drilling sequence and guide-hole design on the accuracy of static computer-assisted implant surgery in extraction sockets and healed sites-An in vitro investigation
    Raabe, Clemens
    Dulla, Fabrice Alain
    Yilmaz, Burak
    Chappuis, Vivianne
    Abou-Ayash, Samir
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (04) : 320 - 329
  • [32] Early implant placement in ridge preserved extraction sockets: A pre-clinical in vivo study
    Rodriguez-Ortiz, Gabriel
    Chen, Stephen
    Davies, Helen
    Fitzgerald, Wayne
    Darby, Ivan
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (06) : 745 - 755
  • [33] Accuracy of Computer-Guided Flapless Implant Surgery in Fully Edentulous Arches and in Edentulous Arches With Fresh Extraction Sockets
    Albiero, Alberto M.
    Quartuccio, Luca
    Benato, Andrea
    Benato, Renato
    IMPLANT DENTISTRY, 2019, 28 (03) : 256 - 264
  • [34] Immediate Provisionalization of Single Narrow Implants in Fresh Extraction Sockets and Healed Sites: Clinical and Radiographic Outcomes of 2 Years Follow-up
    Peron, Cristian
    Romanos, Georgios
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2020, 40 (03) : 417 - 424
  • [35] Review suggests higher failure rates for dental implants placed in fresh extraction sitesQuestion: What is the survival rate of dental implants, postoperative infection, and marginal bone loss of dental implants inserted in fresh extraction sockets compared with healed sites?
    Ismael Khouly
    Analia Veitz Keenan
    Evidence-Based Dentistry, 2015, 16 (2) : 54 - 55
  • [36] Accuracy of Implant Placement Guided with Surgical Template: An In Vitro and In Vivo Study
    Zhou, Miao
    Zhou, Hui
    Li, Shu-Yi
    Yang, Xiao-Bin
    Geng, Yuan-Ming
    Che, Yue-Juan
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2021, 41 (02) : E55 - E62
  • [37] Evaluation of dimensional behavior of peri-implant tissues in implants immediately exposed or submerged in fresh extraction and healed sites: a histological study in dogs
    Alexandre Gehrke, Sergio
    Kathleen Braganca, Leana
    Velasco-Ortega, Eugenio
    Luis Calvo-Guirado, Jose
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [38] Evaluation of dimensional behavior of peri-implant tissues in implants immediately exposed or submerged in fresh extraction and healed sites: a histological study in dogs
    Sergio Alexandre Gehrke
    Leana Kathleen Bragança
    Eugenio Velasco-Ortega
    José Luis Calvo-Guirado
    International Journal of Implant Dentistry, 4
  • [39] Novel Implant Design for Initial Stability of Dental Implants Inserted in Fresh Extraction Sockets: A Preliminary Study
    Levin, Liran
    Frankenthal, Shai
    Zigdon, Hadar
    Suzuki, Marcelo
    Coelho, Paulo G.
    IMPLANT DENTISTRY, 2012, 21 (04) : 302 - 305
  • [40] Outcome After Placement of Tantalum Porous Engineered Dental Implants in Fresh Extraction Sockets: A Canine Study
    Lee, Jin Whan
    Wen, Hai Bo
    Battula, Suneel
    Akella, Rama
    Collins, Michael
    Romanos, Georgios E.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (01) : 134 - 142