Sleeveless guided implant placement compared to conventional approaches: An in vitro study at healed sites and fresh extraction sockets

被引:0
|
作者
Galli, Matthew [1 ]
Mendonca, Gustavo [2 ]
Meneghetti, Priscila [3 ]
Bekkali, Mariam [2 ]
Travan, Suncica [1 ]
Wang, Horn-Lay [1 ]
Li, Junying [1 ,4 ]
机构
[1] Univ Michigan, Dept Periodont & Oral Med, Sch Dent, Ann Arbor, MI USA
[2] Univ Michigan, Dept Biol & Mat Sci, Div Prosthodont, Sch Dent, Ann Arbor, MI USA
[3] Pontificial Catholic Univ Rio Grande, Porto Alegre, Brazil
[4] Univ Michigan, Biol & Mat Sci & Prosthodont, Sch Dent, 1011 N Univ Ave, Ann Arbor, MI 48109 USA
关键词
accuracy; computer-assisted; dental implants; guided surgery; immediate implant placement; PERI-IMPLANTITIS; SURGERY; ACCURACY; ABUTMENT; FREEHAND; ERRORS; RISKS;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To investigate the accuracy of a novel sleeveless implant surgical guide by comparing it with a conventional closed-sleeve guide and a freehand approach. Materials and methods: Custom resin maxillary casts with corticocancellous compartments were used (n = 30). Seven implant sites were present per maxillary cast, corresponding to healed (right and left first premolars, left second premolar and first molar) and extraction sites (right canine and central incisors). The casts were assigned into three groups: freehand (FH), conventional closed -sleeve guide (CG) and surgical guide (SG) groups. Each group comprised 10 casts and 70 implant sites (30 extraction sites and 40 healed sites). Digital planning was used to design 3D printed conventional and surgical guide templates. The primary study outcome was implant deviation. Results: At extraction sites, the largest difference between groups occurred in angular deviation, where the SG group (3.80 +/- 1.67 degrees) exhibited-1.6 times smaller deviation relative to the FH group (6.02 +/- 3.44 degrees; P=0.004). The CG group (0.69 +/- 0.40 mm) exhibited smaller coronal horizontal deviation compared to the SG group (1.08 +/- 0.54 mm; P=0.005). For healed sites, the largest difference occurred for angular deviation, where the SG group (2.31 +/- 1.30 degrees) exhibited 1.9 times smaller deviation relative to the CG group (4.42 +/- 1.51 degrees; P < 0.001), and 1.7 times smaller deviation relative to the FH group (3.84 +/- 2.14 degrees). Significant differences were found for all parameters except depth and coronal horizontal deviation. For the guided groups, there were fewer significant differences between healed and immediate sites compared to the FH group. Conclusion: The novel sleeveless surgical guide showed similar accuracy to the conventional closed-sleeve guide.
引用
收藏
页码:117 / 132
页数:16
相关论文
共 50 条
  • [21] Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis
    Ibrahim, Adam
    Chrcanovic, Bruno Ramos
    MATERIALS, 2021, 14 (24)
  • [22] A STUDY OF IMMEDIATE IMPLANT PLACEMENT IN FRESH EXTRACTION SOCKET
    Konuru, Sriharsha
    Asimuddin, Syed
    Reddy, Venkateshwara
    Reddy, Haranadha
    Reddy, Sekhar
    Reddy, Siva Prasada
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (08): : 489 - 493
  • [23] Immediate implant placement in extraction sockets with buccal bone dehiscence: A case study
    Dragonas, Panagiotis
    CLINICAL ADVANCES IN PERIODONTICS, 2024,
  • [24] Sinus floor elevation and simultaneous implant placement in fresh extraction sockets: a systematic review of clinical data
    Ekhlasmandkermani, Mehdi
    Amid, Reza
    Kadkhodazadeh, Mahdi
    Hajizadeh, Farhad
    Abed, Pooria Fallah
    Kheiri, Lida
    Kheiri, Aida
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2021, 47 (06) : 411 - 426
  • [26] IMMEDIATE IMPLANT PLACEMENT INTO EXTRACTION SITES - A RETROSPECTIVE STUDY
    SCHWARTZARAD, D
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 960 - 960
  • [27] Esthetic Evaluation of Single-Tooth Worse Taper Connection Implants Placed in Fresh Extraction Sockets or Healed Sites
    Mangano, Francesco G.
    Mangano, Carlo
    Ricci, Massimiliano
    Sammons, Rachel L.
    Shibli, Jamil A.
    Piattelli, Adriano
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (02) : 172 - 181
  • [28] Bone modelling at fresh extraction sockets: immediate implant placement versus spontaneous healing. An experimental study in the beagle dog
    Vignoletti, Fabio
    Discepoli, Nicola
    Mueller, Anna
    Sanctis, Massimo
    Munoz, Fernando
    Sanz, Mariano
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2012, 39 (01) : 91 - 97
  • [29] Lingualized Flapless Implant Placement into Fresh Extraction Sockets Preserves Buccal Alveolar Bone: A Cone Beam Computed Tomography Study
    Lee, Ernesto A.
    Gonzalez-Martin, Oscar
    Fiorellini, Joseph
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2014, 34 (01) : 61 - 68
  • [30] Immediate Implant Placement into Fresh Extraction Socket in the Mandibular Molar Sites: A Preliminary Study of a Modified Insertion Technique
    Hamouda, Nelly I.
    Mourad, Samah I.
    El-Kenawy, Mohamed H.
    Maria, Ola M.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E107 - E116