Evaluation of Diasorin Liaison® calprotectin fecal assay adapted for pleural effusion

被引:0
|
作者
Poves, Cristina de Paz [5 ]
Barneo-Caragol, Clara [1 ]
Sanchez, Ana Isabel Cillero [2 ]
Mendiguchia, Lucia Jimenez [3 ]
Caso, Covadonga Quiros [1 ]
Rodriguez, Maria Moreno [3 ]
Gonzalez, Francisco J. Lopez [4 ]
Garcia, Ma Belen Prieto [1 ]
机构
[1] Hosp Univ Cent Asturias, Dept Clin Biochem, Lab Med, Oviedo, Asturias, Spain
[2] Hosp Alvarez Buylla, Dept Clin Biochem, Mieres, Asturias, Spain
[3] Hosp Univ San Agustin, Dept Clin Biochem, Aviles, Asturias, Spain
[4] Hosp Univ Cent Asturias, Dept Pneumol, Oviedo, Asturias, Spain
[5] Hosp Univ Cent Asturias, Dept Clin Biochem, Lab Med, Ave Roma S-N, Oviedo 33011, Asturias, Spain
关键词
automation; calprotectin; chemiluminescence; pleural fluid; validation; MARKER;
D O I
10.1515/almed-2023-0106
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Calprotectin (CP) is a calcium and zinc binding protein that is widely measured on faecal samples but its determination in other biological fluids might be of interest. The aim of this work was to validate the measurement of CP in pleural fluid by chemiluminescence.Methods: LIAISON (R) XL, a fully automated chemiluminescence analyzer, was used for CP quantification on pleural fluid. A validation protocol was designed using both quality control materials provided by the manufacturer and pools of pleural fluid samples. Stability, imprecision, bias, linearity, detection capability and carry over effect were evaluated.Results: CP was stable on pleural fluid at least one week, under refrigerated conditions, and four weeks at -80 80 degrees C. The observed intra- and inter-day imprecision was between 2.2 and 6.49 %, with a negative bias under 5.51 %. The linearity of the method was verified up to 2,000 ng/mL. The LoQ for the assay was 48.52 ng/mL. A statistically significant carry-over effect was observed after measuring CP concentrations above the upper limit of linearity, but given the observed magnitude, a clinically relevant impact should not be expected.Conclusions: Diasorin Liaison (R) calprotectin assay allows reliable measurement of CP in pleural fluid.
引用
收藏
页码:419 / 424
页数:6
相关论文
共 50 条
  • [31] Performance evaluation of the Diasorin LIAISON® XL Zika capture IgM CLIA test
    Van der Beken, Y.
    De Geyter, D.
    Van Esbroeck, M.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2019, 95 (02) : 144 - 148
  • [32] Evaluation of a fluorescent immunochromatography test for fecal calprotectin
    Li, Runqing
    Zhao, Xiuying
    Dong, Jingxiao
    Zhu, Dong
    Wang, Tengjiao
    Yang, Song
    Zhao, Zhipeng
    Xiao, Nan
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2020, 34 (02)
  • [33] Method evaluation of an automated fecal calprotectin immunoassay
    Miller, Jessica
    Henderson, Tina
    Jung, Benjamin P.
    Adeli, Khosrow
    Sepiashvili, Lusia
    CLINICAL BIOCHEMISTRY, 2022, 109 : 111 - 111
  • [34] ADA assay in pleural fluids: A diagnostic tool in tuberculosis pleural effusion
    Vats, M
    Doctor, R
    Gupta, RC
    Dadhich, P
    Vats, D
    Gupta, N
    Taylor, M
    CHEST, 2003, 124 (04) : 115S - 115S
  • [35] Fecal Calprotectin for the Evaluation of Inflammatory Bowel Disease
    Bryce, Carl
    Bucaj, Merima
    AMERICAN FAMILY PHYSICIAN, 2021, 104 (02) : 303 - 304
  • [36] Fecal Calprotectin Evaluation in Patients with Ulcerative Colitis
    Tolga Dogan
    Mehmet Agilli
    Digestive Diseases and Sciences, 2015, 60 : 1109 - 1110
  • [37] Clinical Accuracy of a New Rapid Assay for Fecal Calprotectin Measurement
    Ashorov, Olga
    Hamouda, Dalal
    Dickman, Ram
    Perets, Tsachi Tsadok
    CLINICAL LABORATORY, 2020, 66 (04) : 671 - 675
  • [38] Fecal calprotectin levels in healthy children studied with an improved assay
    Fagerberg, UL
    Lööf, L
    Merzoug, RD
    Hansson, LO
    Finkel, Y
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2003, 37 (04): : 468 - 472
  • [39] The value of fecal calprotectin assay in chronic panniculitis of unknown etiology
    Kaddour, K.
    Lemasson, J.
    Haettich-Pialoux, B.
    Guedj, N.
    Belmatoug, N.
    Treton, X.
    Becheur, H.
    Fantin, B.
    Descamps, V.
    Le Bozec, P.
    ANNALES DE DERMATOLOGIE ET DE VENEREOLOGIE, 2018, 145 (11): : 702 - 705
  • [40] Evaluation of diasorin Quantiferon-TB Gold Plus test using Liaison XL
    Stojkovic, V.
    Cavalier, E.
    Lutteri, L.
    CLINICA CHIMICA ACTA, 2019, 493 : S561 - S561