Gridless adult cervical spine radiography and its' effect on image quality and radiation dose: A phantom study

被引:0
|
作者
Mekis, N. [1 ,6 ]
Bianchi, T. [2 ]
Doyle, C. [3 ]
Gauchat, M. [2 ]
Geerling, I. [4 ]
Linneman, J. [4 ]
Staats, S. [5 ]
Campeanu, C. [2 ]
机构
[1] Univ Ljubljana, Med Imaging & Radiotherapy Dept, Zdravstvena Pot 5, Ljubljana 100, Slovenia
[2] Univ Appl Sci & Arts Western Switzerland HES SO, Sch Hlth Sci HESAV, Dept Tech Med Radiol, Ave Beaumont 21, CH-1011 Lausanne, Switzerland
[3] Univ Coll Dublin, Sch Med, Radiog & Diagnost Imaging, Dublin 4, Ireland
[4] Hanze Univ Appl Sci, Dept Med Imaging & Radiat Therapy, Petrus Driessenstr 3, NL-9714 CA Groningen, Netherlands
[5] Cent Univ Technol, Dept Clin Sci, Radiog Diagnost, Bloemfontein, South Africa
[6] Zdravstvena Pot 5, Ljubljana 1000, Slovenia
关键词
Antero-posterior C -spine; Lateral C -spine; Anti-scatter grid; Digital radiography; Image quality; Dose reduction;
D O I
10.1016/j.radi.2023.12.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Imaging of the cervical spine in general radiography is most frequently performed using an anti-scatter grid. The purpose of this study was to investigate the effects of a gridless setting on image quality and radiation dose during digital radiography of the anteroposterior (AP) and lateral (LAT) cervical spine.Methods: A phantom study was performed with a variety of tube voltages (63-75 kV) with and without an anti-scatter grid. The tube current time product (mAs) and dose area product (DAP) were recorded and used to calculate effective dose (ED) and individual organ dose using PCXMC 2.0 software, as well as entrance surface dose (ESD) and objective image quality: signal-to-noise ratio (SNR) and contrast-tonoise ratio (CNR). Subjective visual image quality grading characteristics (VGC) was performed by five qualified radiographers.Results: In a gridless setting, the AP and LAT positions showed significantly lower DAP (1.6 mu Gym2; 61.3 % and 1.6 mu Gym2; 51.2%), ESD (27.6 mu Gy; 57.3% and 77.2 mu Gy; 47.2%) and ED (4.2 mu Sv; 61.3% and 2.3 mu Sv; 48.9%). In a gridless setting in the AP position, there is a slight significant deterioration in image quality. In the lateral projection, on the other hand, the image quality without the use of grid was only significantly reduced in three of six criteria and there was no difference in the objective image quality between the two settings examined.Conclusion: The results of this study show that gridless setting significantly decreases radiation dose and image quality, but the quality in the lateral projection is still acceptable for diagnostic purpose. Implications for practice: The protocol without the use of the anti-scatter grid in cervical spine radiography leads to a reduction in the radiation dose in both projections, but the image quality in the AP is significantly reduced for all criteria examined, with a slight deterioration in image quality in the lateral projection.(c) 2023 The Authors. Published by Elsevier Ltd on behalf of The College of Radiographers. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:359 / 366
页数:8
相关论文
共 50 条
  • [31] Digital radiography: The balance between image quality and required radiation dose
    Uffmann, Martin
    Schaefer-Prokop, Cornelia
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (02) : 202 - 208
  • [32] Supine and erect abdominal radiography: A comparison of radiation dose and image quality
    Alzyoud, Kholoud
    Al-Murshedi, Sadeq
    Abualkhael, Khaleda
    Alqawasmeh, Farah
    England, Andrew
    APPLIED RADIATION AND ISOTOPES, 2022, 190
  • [33] Optimisation of radiation dose and image quality in mobile neonatal chest radiography
    Hinojos-Armendariz, V. I.
    Mejia-Rosales, S. J.
    Franco-Cabrera, M. C.
    RADIOGRAPHY, 2018, 24 (02) : 104 - 109
  • [34] Achievable Radiation Dose Reduction with Comparable Image Quality in Chest Radiography
    Wan, A. Y. H.
    Shih, M. H.
    Lai, B. M. H.
    Chu, C. Y.
    Tang, K. Y. K.
    Chan, R. T. M.
    Khoo, J. L. S.
    HONG KONG JOURNAL OF RADIOLOGY, 2014, 17 (03): : 182 - 188
  • [35] conventional radiography and computed tomography to cervical spine study of adult horses - review
    de Souza, Livia Pasini
    Sesoko, Natalia Ferreira
    dos Santos, Roberta Valeriano
    Evangelista, Felipe Carvalho
    de Vasconcelos Machado, Vania Maria
    Vulcano, Luiz Carlos
    MEDICINA VETERINARIA-RECIFE, 2011, 5 (04): : 238 - 240
  • [36] Development of a computed tomography phantom to evaluate radiation dose and image quality
    Gomez Cardona, Daniel
    Estrada Leon, Edgar Santiago
    Zuluaga Santamaria, Alejandro
    Benitez, Luis
    Ramirez Giraldo, Juan Carlos
    2013 PAN AMERICAN HEALTH CARE EXCHANGES (PAHCE), 2013,
  • [37] Effect of the CT Table Strap on Radiation Exposure and Image Quality during Cervical Spine CT
    Kranz, P. G.
    Wylie, J. D.
    Hoang, J. K.
    Kosinski, A. S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (10) : 1870 - 1876
  • [38] How Localizer Orders Impact Image Quality and Radiation Dose in Computed Tomography - A Phantom Study
    Jimenez, J.
    Rong, J.
    Jensen, C.
    Jones, A.
    Liu, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E538 - E538
  • [39] Image quality and radiation dose in planar imaging - Image quality figure of merits from the CDRAD phantom
    Konst, Bente
    Weedon-Fekjaer, Harald
    Bath, Magnus
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (07): : 151 - 159
  • [40] Can the anode heel effect be used to optimise radiation dose and image quality for AP pelvis radiography?
    Mraity, H. A. A. B.
    Walton, L.
    England, A.
    Thompson, J.
    Lanca, L.
    Hogg, P.
    RADIOGRAPHY, 2020, 26 (02) : E103 - E108