Improved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients

被引:3
|
作者
Kang, Daehun [1 ]
In, Myung-Ho [1 ]
Jo, Hang Joon [1 ,2 ]
Halverson, Maria A. [1 ]
Meyer, Nolan K. [1 ,3 ]
Ahmed, Zaki [1 ]
Gray, Erin M. [1 ]
Madhavan, Radhika [4 ]
Foo, Thomas K. [4 ]
Fernandez, Brice [5 ]
Black, David F. [1 ]
Welker, Kirk M. [1 ]
Trzasko, Joshua D. [1 ]
Huston III, John [1 ]
Bernstein, Matt A. [1 ]
Shu, Yunhong [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Hanyang Univ, Dept Physiol, Seoul 04763, South Korea
[3] Mayo Clin, Mayo Clin Grad Sch Biomed Sci, Rochester, MN 55905 USA
[4] GE Global Res, Niskayuna, NY 12309 USA
[5] GE Healthcare, F-78530 Buc, France
基金
美国国家卫生研究院;
关键词
fMRI; BOLD; resting state; multi-echo EPI; compact; 3T; gradient system; slew rate; BOLD-CONTRAST SENSITIVITY; TASK-BASED FMRI; BRAIN; NOISE; EPI; COMPENSATION; NONLINEARITY; ENHANCEMENT; SIGNALS;
D O I
10.3390/s23094329
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In blood-oxygen-level-dependent (BOLD)-based resting-state functional (RS-fMRI) studies, usage of multi-echo echo-planar-imaging (ME-EPI) is limited due to unacceptable late echo times when high spatial resolution is used. Equipped with high-performance gradients, the compact 3T MRI system (C3T) enables a three-echo whole-brain ME-EPI protocol with smaller than 2.5 mm isotropic voxel and shorter than 1 s repetition time, as required in landmark fMRI studies. The performance of the ME-EPI was comprehensively evaluated with signal variance reduction and region-of-interest-, seed- and independent-component-analysis-based functional connectivity analyses and compared with a counterpart of single-echo EPI with the shortest TR possible. Through the multi-echo combination, the thermal noise level is reduced. Functional connectivity, as well as signal intensity, are recovered in the medial orbital sulcus and anterior transverse collateral sulcus in ME-EPI. It is demonstrated that ME-EPI provides superior sensitivity and accuracy for detecting functional connectivity and/or brain networks in comparison with single-echo EPI. In conclusion, the high-performance gradient enabled high-spatial-temporal resolution ME-EPI would be the method of choice for RS-fMRI study on the C3T.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] MRI of the knee: value of short echo time fast spin-echo using high performance gradients versus conventional spin-echo imaging for the detection of meniscal tears
    Kowalchuk, RM
    Kneeland, JB
    Dalinka, MK
    Siegelman, ES
    Dockery, WD
    SKELETAL RADIOLOGY, 2000, 29 (09) : 520 - 524
  • [42] Functional MRI at 3T using intermolecular double-quantum coherence (iDQC) with spin-echo (SE) acquisitions
    T. Gu
    S. D. Kennedy
    Z. Chen
    K. A. Schneider
    J. Zhong
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2007, 20 : 255 - 264
  • [43] Functional MRI at 3T using intermolecular double-quantum coherence (iDQC) with spin-echo (SE) acquisitions
    Gu, T.
    Kennedy, S. D.
    Chen, Z.
    Schneider, K. A.
    Zhong, J.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2007, 20 (5-6) : 255 - 264
  • [44] Association between Tumor Acidity and Hypervascularity in Human Gliomas Using pH-Weighted Amine Chemical Exchange Saturation Transfer Echo-Planar Imaging and Dynamic Susceptibility Contrast Perfusion MRI at 3T
    Wang, Y. -L.
    Yao, J.
    Chakhoyan, A.
    Raymond, C.
    Salamon, N.
    Liau, L. M.
    Nghiemphu, P. L.
    Lai, A.
    Pope, W. B.
    Nguyen, N.
    Ji, M.
    Cloughesy, T. F.
    Ellingson, B. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (06) : 979 - 986
  • [45] Robust Fat Suppression at 3T in High-Resolution Diffusion-Weighted Single-Shot Echo-Planar Imaging of Human Brain
    Sarlls, Joelle E.
    Pierpaoli, Carlo
    Talagala, S. Lalith
    Luh, Wen-Ming
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (06) : 1658 - 1665
  • [46] BOLD BASED FUNCTIONAL MRI AT 4-TESLA INCLUDES A CAPILLARY BED CONTRIBUTION - ECHO-PLANAR IMAGING CORRELATES WITH PREVIOUS OPTICAL IMAGING USING INTRINSIC SIGNALS
    MENON, RS
    OGAWA, S
    HU, XP
    STRUPP, JP
    ANDERSON, P
    UGURBIL, K
    MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (03) : 453 - 459
  • [47] Accelerated spin-echo functional MRI using multisection excitation by simultaneous spin-echo interleaving (MESSI) with complex-encoded generalized slice dithered enhanced resolution (cgSlider) simultaneous multislice echo-planar imaging
    Han, SoHyun
    Liao, Congyu
    Manhard, Mary Kate
    Park, Daniel Joseph
    Bilgic, Berkin
    Fair, Merlin J.
    Wang, Fuyixue
    Blazejewska, Anna, I
    Grissom, William A.
    Polimeni, Jonathan R.
    Setsompop, Kawin
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (01) : 206 - 220
  • [48] Rapid Quantitative T2 Mapping of the Prostate Using Three-Dimensional Dual Echo Steady State MRI at 3T
    Dregely, Isabel
    Margolis, Daniel A. J.
    Sung, Kyunghyun
    Zhou, Ziwu
    Rangwala, Novena
    Raman, Steven S.
    Wu, Holden H.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (06) : 1720 - 1729
  • [49] Using multi-echo simultaneous multi-slice (SMS) EPI to improve functional MRI of the subcortical nuclei of the basal ganglia at ultra-high field (7T)
    Puckett, Alexander M.
    Bollmann, Saskia
    Poser, Benedikt A.
    Palmer, Jake
    Barth, Markus
    Cunnington, Ross
    NEUROIMAGE, 2018, 172 : 886 - 895
  • [50] High-speed real-time resting-state fMRI using multi-slab echo-volumar imaging
    Posse, Stefan
    Ackley, Elena
    Mutihac, Radu
    Zhang, Tongsheng
    Hummatov, Ruslan
    Akhtari, Massoud
    Chohan, Muhammad
    Fisch, Bruce
    Yonas, Howard
    FRONTIERS IN HUMAN NEUROSCIENCE, 2013, 7