Mode Analysis, Transformer Saturation, and Fault Diagnosis Technique for an Open-Circuit Fault in a Three-Phase DAB Converter

被引:20
|
作者
Rastogi, Sagar Kumar [1 ]
Shah, Suyash Sushilkumar [2 ]
Singh, Brij N. [3 ]
Bhattacharya, Subhashish [1 ]
机构
[1] North Carolina State Univ, ECE Dept, Raleigh 27606, NC USA
[2] Tesla Inc, Palo Alto, CA 94304 USA
[3] John Deere Inc, Fargo, ND 58102 USA
关键词
DAB; dc-dc converter; detection; diagnosis; dual active bridge; fault; magnetization; mode analysis; open circuit fault (OCF); saturation; three phase; transformer; DC-DC CONVERTERS; TOLERANT CONTROL;
D O I
10.1109/TPEL.2023.3241654
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The three-phase dual active bridge (DAB3) is a popular dc-dc converter topology for high-power applications, capable of high-efficiency bidirectional power transfer with galvanic isolation. A single point of failure in power converters is the open-circuit fault (OCF) due to failure in a semiconductor device or its gate drive circuit. This study presents detailed waveform analyses for the normal- and the fault-mode operation. A novel logic-based fault diagnosis scheme is proposed based on the unique pattern in the dc bias of phase currents. Unlike previous schemes, the proposed scheme requires low-bandwidth current sensing only one side of the transformer to detect faults on either side, providing a cost and design benefit. Experimental results verify the analyses and the proposed identification scheme, detecting the fault within a few switching cycles. An in-depth study of the transformer under fault mode is presented for the first time, setting a guideline of time available for fault diagnosis and response. Experimental B-H curves and magnetizing currents of the three-phase transformer illustrate the cycle-by-cycle progression toward core saturation under fault mode. The study also reveals a new potential benefit of the three-phase DAB over the single-phase DAB; i.e., even in the presence of a secondary-side OCF, the DAB3 may continue to operate normally at full load.
引用
收藏
页码:7644 / 7660
页数:17
相关论文
共 50 条
  • [21] Open-circuit Fault Diagnosis of Three-phase Inverter for Grid-connected Distributed Generation System
    Fan, Chaodong
    Liu, Yingnan
    Yi, Lingzhi
    10TH ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC 2018), 2018, : 246 - 254
  • [22] Open-Circuit Fault Diagnosis Based on the Filter Inductor Voltage for Single- and Three-Phase Inverters
    Pei, Xuebing
    PROCEEDINGS OF THE 2015 INTERNATIONAL POWER, ELECTRONICS AND MATERIALS ENGINEERING CONFERENCE, 2015, 17 : 327 - 333
  • [23] A Transferrable Data-Driven Method for IGBT Open-Circuit Fault Diagnosis in Three-Phase Inverters
    Xia, Yang
    Xu, Yan
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (12) : 13478 - 13488
  • [24] An Online Open-Circuit Fault Diagnosis and Fault Tolerant Scheme for Three-Phase AC-DC Converters with Model Predictive control
    Zhou, Dehong
    Tang, Yi
    2018 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-NIIGATA 2018 -ECCE ASIA), 2018, : 434 - 438
  • [25] Comparison of Fault Tolerant Control Techniques for Quadruple Three-Phase Induction Machines Under Open-Circuit Fault
    Sala, G.
    Girardini, P.
    Mengoni, M.
    Zarri, L.
    Tani, A.
    Serra, G.
    2017 IEEE 11TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2017, : 213 - 219
  • [26] Control of Three-Phase Induction Machine Drives During Open-Circuit Fault: A Review
    Tabasian, Rahemeh
    Ghanbari, Mahmood
    Esmaeli, Abdolreza
    Jannati, Mohammad
    IETE JOURNAL OF RESEARCH, 2022, 68 (04) : 2622 - 2639
  • [27] Open-circuit fault detection for three-phase inverter based on backpropagation neural network
    Ji, Zhendong
    Liu, Wei
    NEURAL COMPUTING & APPLICATIONS, 2019, 31 (09): : 4665 - 4674
  • [28] Open-circuit fault detection for three-phase inverter based on backpropagation neural network
    Zhendong Ji
    Wei Liu
    Neural Computing and Applications, 2019, 31 : 4665 - 4674
  • [29] Research of open-circuit fault simulation and diagnosis for wind power converter
    Zhang, Wei
    Ling, Qihui
    Zhao, Qiancheng
    Wang, Xian
    Zeng, Bing
    NINTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, 2019, 11343
  • [30] Transistor open-circuit fault diagnosis in two-level three-phase inverter based on similarity measurement
    Hang, Cuicui
    Ying, Liming
    Shu, Naiqiu
    MICROELECTRONICS RELIABILITY, 2018, 91 : 291 - 297