Mode Analysis, Transformer Saturation, and Fault Diagnosis Technique for an Open-Circuit Fault in a Three-Phase DAB Converter

被引:20
|
作者
Rastogi, Sagar Kumar [1 ]
Shah, Suyash Sushilkumar [2 ]
Singh, Brij N. [3 ]
Bhattacharya, Subhashish [1 ]
机构
[1] North Carolina State Univ, ECE Dept, Raleigh 27606, NC USA
[2] Tesla Inc, Palo Alto, CA 94304 USA
[3] John Deere Inc, Fargo, ND 58102 USA
关键词
DAB; dc-dc converter; detection; diagnosis; dual active bridge; fault; magnetization; mode analysis; open circuit fault (OCF); saturation; three phase; transformer; DC-DC CONVERTERS; TOLERANT CONTROL;
D O I
10.1109/TPEL.2023.3241654
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The three-phase dual active bridge (DAB3) is a popular dc-dc converter topology for high-power applications, capable of high-efficiency bidirectional power transfer with galvanic isolation. A single point of failure in power converters is the open-circuit fault (OCF) due to failure in a semiconductor device or its gate drive circuit. This study presents detailed waveform analyses for the normal- and the fault-mode operation. A novel logic-based fault diagnosis scheme is proposed based on the unique pattern in the dc bias of phase currents. Unlike previous schemes, the proposed scheme requires low-bandwidth current sensing only one side of the transformer to detect faults on either side, providing a cost and design benefit. Experimental results verify the analyses and the proposed identification scheme, detecting the fault within a few switching cycles. An in-depth study of the transformer under fault mode is presented for the first time, setting a guideline of time available for fault diagnosis and response. Experimental B-H curves and magnetizing currents of the three-phase transformer illustrate the cycle-by-cycle progression toward core saturation under fault mode. The study also reveals a new potential benefit of the three-phase DAB over the single-phase DAB; i.e., even in the presence of a secondary-side OCF, the DAB3 may continue to operate normally at full load.
引用
收藏
页码:7644 / 7660
页数:17
相关论文
共 50 条
  • [11] A Fault Diagnosis Method Based on Output Voltage Patterns for Switch Open-circuit Fault of Three-phase Inverters
    Xu, Xiaojian
    Yu, Fei
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2024, 44 (03): : 1106 - 1116
  • [12] Fault diagnosis method for open-circuit switches in three-phase inverters based on current value analysis
    Luo, Yu
    Chen, Chunyang
    Shi, Yingchun
    Zeng, Xiaojun
    Journal of Railway Science and Engineering, 2024, 21 (10) : 4370 - 4382
  • [13] Open-circuit fault diagnosis for three-phase inverters based on CNN and analysis of its sample conditions
    Shen H.
    Tang X.
    Luo Y.
    Xiao F.
    Ai S.
    Fan Y.
    Guofang Keji Daxue Xuebao/Journal of National University of Defense Technology, 2022, 44 (06): : 163 - 172
  • [14] Open Circuit Fault Diagnosis and Fault Tolerance of Three-Phase Bridgeless Rectifier
    Cheng, Hong
    Chen, Wenbo
    Wang, Cong
    Deng, Jiaqing
    ELECTRONICS, 2018, 7 (11):
  • [15] State Observer-Based Open-Circuit Fault Diagnosis and Localization Research of DAB Converter
    Qi, Jiaming
    Yu, Fei
    Yue, Xiaoqian
    Xue, Haoyang
    2024 IEEE 2ND INTERNATIONAL CONFERENCE ON POWER SCIENCE AND TECHNOLOGY, ICPST 2024, 2024, : 1032 - 1038
  • [16] A Transferable Deep Learning Network for IGBT Open-circuit Fault Diagnosis in Three-phase Inverters
    Liu, Yongjie
    Sangwongwanich, Ariya
    Zhang, Yi
    Ou, Shuyu
    Wang, Huai
    2024 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2024, : 1229 - 1234
  • [17] Application of artificial neural networks for transistor open-circuit fault diagnosis in three-phase rectifiers
    Sobanski, Piotr
    Kaminski, Marcin
    IET POWER ELECTRONICS, 2019, 12 (09) : 2189 - 2200
  • [18] Multiple open-circuit fault diagnosis of three-phase rectifier based on current data reconstruction
    Tian, Lisi
    Hu, Bin
    Cao, Xiaoguang
    Zhang, Hongwei
    Yu, Qiang
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2023, 110 (07) : 1267 - 1282
  • [19] A Path-Based Switch Open Circuit Fault-Tolerant Method for Three-Phase DAB Converter
    Guan, Yuanpeng
    Xiao, Yiting
    Qin, Li
    Liu, Xiong
    Deng, Hui
    Wu, Weixiong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (01) : 1577 - 1595
  • [20] Open-Circuit Fault Diagnosis for Dual Three-Phase Permanent Magnet Machine Considering Nonideal Condition
    Guo, Lingling
    Wang, K.
    Wang, Tao
    Cao, Ruiwu
    Li, Feng
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (09) : 10288 - 10296