A comparison of 3-D CT and 2-D plain radiograph measurements of the wrist in extra-articular malunited fractures of the distal radius

被引:0
|
作者
Smees, Camiel J. [1 ,2 ,4 ]
van Es, Eline M. [3 ]
Tuijthof, Gabrielle J. M. [2 ]
Colaris, Joost W. [3 ]
de Graaff, Feike [1 ]
Vochteloo, Anne J. H. [1 ]
机构
[1] Ctr Orthopaed Surg & Sports Med, OCON, Hengelo, Netherlands
[2] Univ Twente, Biomed Device Design & Prod Technol, Enschede, Netherlands
[3] Erasmus MC, Dept Orthopaed & Sports Med, Rotterdam, Netherlands
[4] Ctr Orthopaed Surg & Sports Med, OCON, Geerdinksweg 141, NL-7555DL Hengelo, Netherlands
关键词
Radial inclination; volar tilt; palmar tilt; ulnar length; axial rotation; diagnostics; radius malunion; CORRECTIVE OSTEOTOMY; COORDINATE SYSTEMS; COLLES FRACTURE; CARPAL BONES; MOTION;
D O I
10.1177/17531934231213790
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Two-dimensional (2-D) plain radiographs may be insufficient for the evaluation of distal radial malunion, as it is a three-dimensional (3-D) deformity. This study introduced a 3-D measuring method that outputs radial inclination, ulnar variance, palmar tilt and axial rotation. To this end, a standardized and clearly defined coordinate system was constructed that allowed 3-D measurements closely resembling the conventional 2-D method in 35 patients. Mean differences between 3-D and 2-D measurements in affected wrists were 1.8 degrees for radial inclination, 0.8 mm for ulnar variance and 3.7 degrees for palmar tilt. In addition, inter- and intra-observer reproducibility of all 3-D and 2-D measurements were good or excellent (intraclass correlation coefficient >0.75), with 3-D reproducibility always better than 2-D. Axial rotation was present in all patients with a mean of 7.9 degrees (SD 6.9). Although the differences between 2-D and 3-D measurements were small, 3-D evaluation enables the assessment of axial rotation and brings us closer to a routine 3-D evaluation of malunion.
引用
收藏
页码:546 / 553
页数:8
相关论文
共 50 条
  • [41] Comparison of Fully 3-D,Simplified 3-D and 2-D Numerical Simulations on a Circulating Fluidized Bed Boiler
    LI Kun
    CHENG Leming
    MA Zhangke
    LUO Guanwen
    LI Liyao
    ZHANG Qingyu
    GUO Qiang
    ZHAO Liang
    JournalofThermalScience, 2023, 32 (05) : 1832 - 1848
  • [42] Comparison of intraoperative 2D vs. 3D imaging in open reduction and fixation of distal radius fractures
    Hammerle, Diego
    Osterhoff, Georg
    Allemann, Florin
    Werner, Clement Max Leonard
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2020, 46 (03) : 557 - 563
  • [43] 2-D and 3-D interpretation of electrical tomography measurements, Part 2: The inverse problem
    Lesur, V
    Cuer, M
    Straub, A
    GEOPHYSICS, 1999, 64 (02) : 396 - 402
  • [44] 2-D and 3-D interpretation of electrical tomography measurements, part 2: The inverse problem
    Lesur, Vincent
    Cuer, Michel
    Straub, André
    Geophysics, 64 (02): : 396 - 402
  • [45] Measurements on the Absolute 2-D and 3-D Localization Accuracy of TerraSAR-X
    Balss, Ulrich
    Gisinger, Christoph
    Eineder, Michael
    REMOTE SENSING, 2018, 10 (04):
  • [46] Reconstructing 3-D block size distributions from 2-D measurements on sections
    Maerz, NH
    MEASUREMENT OF BLAST FRAGMENTATION, 1996, : 39 - 43
  • [47] 3-D/2-D registration of CT and MR to X-ray images
    Tomazevic, D
    Likar, B
    Slivnik, T
    Pernus, F
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) : 1407 - 1416
  • [48] Quantitative 3-D CT Demonstrates Distal Row Pronation and Translation and Radiolunate Arthritis in the SNAC Wrist
    Miyamura, Satoshi
    Shiode, Ryoya
    Lans, Jonathan
    Oka, Kunihiro
    Tanaka, Hiroyuki
    Okada, Seiji
    Murase, Tsuyoshi
    Chen, Neal C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2023, 105 (17): : 1329 - 1337
  • [49] Comparison of Passive 2-D and 3-D Ring Arrays for Medical Telemetry Focusing
    Bernety, Hossein Mehrpour
    Puckett, Richard D.
    Schurig, David
    Furse, Cynthia
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2019, 18 (06): : 1189 - 1193
  • [50] Numerical Simulation in Rockfall Analysis: A Close Comparison of 2-D and 3-D DDA
    Guangqi Chen
    Lu Zheng
    Yingbin Zhang
    Jian Wu
    Rock Mechanics and Rock Engineering, 2013, 46 : 527 - 541