A comparison of 3-D CT and 2-D plain radiograph measurements of the wrist in extra-articular malunited fractures of the distal radius

被引:0
|
作者
Smees, Camiel J. [1 ,2 ,4 ]
van Es, Eline M. [3 ]
Tuijthof, Gabrielle J. M. [2 ]
Colaris, Joost W. [3 ]
de Graaff, Feike [1 ]
Vochteloo, Anne J. H. [1 ]
机构
[1] Ctr Orthopaed Surg & Sports Med, OCON, Hengelo, Netherlands
[2] Univ Twente, Biomed Device Design & Prod Technol, Enschede, Netherlands
[3] Erasmus MC, Dept Orthopaed & Sports Med, Rotterdam, Netherlands
[4] Ctr Orthopaed Surg & Sports Med, OCON, Geerdinksweg 141, NL-7555DL Hengelo, Netherlands
关键词
Radial inclination; volar tilt; palmar tilt; ulnar length; axial rotation; diagnostics; radius malunion; CORRECTIVE OSTEOTOMY; COORDINATE SYSTEMS; COLLES FRACTURE; CARPAL BONES; MOTION;
D O I
10.1177/17531934231213790
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Two-dimensional (2-D) plain radiographs may be insufficient for the evaluation of distal radial malunion, as it is a three-dimensional (3-D) deformity. This study introduced a 3-D measuring method that outputs radial inclination, ulnar variance, palmar tilt and axial rotation. To this end, a standardized and clearly defined coordinate system was constructed that allowed 3-D measurements closely resembling the conventional 2-D method in 35 patients. Mean differences between 3-D and 2-D measurements in affected wrists were 1.8 degrees for radial inclination, 0.8 mm for ulnar variance and 3.7 degrees for palmar tilt. In addition, inter- and intra-observer reproducibility of all 3-D and 2-D measurements were good or excellent (intraclass correlation coefficient >0.75), with 3-D reproducibility always better than 2-D. Axial rotation was present in all patients with a mean of 7.9 degrees (SD 6.9). Although the differences between 2-D and 3-D measurements were small, 3-D evaluation enables the assessment of axial rotation and brings us closer to a routine 3-D evaluation of malunion.
引用
收藏
页码:546 / 553
页数:8
相关论文
共 50 条
  • [21] 3-D versus 2-D Animation in Multimedia Application: Is the Extra Effort Worth It?
    Rias, Riaza Mohd
    Zaman, Halimah Badioze
    DIGITAL INFORMATION PROCESSING AND COMMUNICATIONS, PT 2, 2011, 189 : 147 - +
  • [22] Biomechanical Comparison of Dorsal Nail Plate Versus Screw and K-Wire Construct for Extra-Articular Distal Radius Fractures in a Cadaver Bone Model
    Klitscher, Daniela
    Mehling, Isabella
    Nowak, Lukas
    Nowak, Tobias
    Rornmens, Pol M.
    Mueller, Lars P.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (04): : 611 - 618
  • [23] COMPARISON OF 2-D AND 3-D DYNAMIC ANALYSES OF EARTH DAMS
    MEJIA, LH
    SEED, HB
    JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1983, 109 (11): : 1383 - 1398
  • [24] Comparison Between 2-D and 3-D Electromagnetic Modeling of Railgun
    Shvetsov, Gennady A.
    Stankevich, Sergey V.
    IEEE TRANSACTIONS ON MAGNETICS, 2009, 45 (01) : 453 - 457
  • [25] Computer-assisted 3D preoperative planning of corrective osteotomy for extra-articular distal radius malunion: A 16-patient case series
    Athlani, L.
    Chenel, A.
    Detammaecker, R.
    De Almeida, Y-K
    Dautel, G.
    HAND SURGERY & REHABILITATION, 2020, 39 (04): : 275 - 283
  • [26] PREAORTIC ILIAC VENOUS CONFLUENCE - 2-D AND 3-D CT FINDINGS
    HARMAN, JT
    KOPECKY, KK
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1992, 16 (01) : 51 - 53
  • [27] 3-D track initiation in clutter using 2-D radar measurements
    Lin, L
    Kirubarajan, T
    Bar-Shalom, Y
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2002, 38 (04) : 1434 - 1441
  • [28] Comparison of morphological predictions in the Lower Rhine River by means of a 2-D and 3-D model and in situ measurements
    Backhaus, L.
    Brudy-Zippelius, T.
    Wenka, T.
    Riesterer, J.
    RIVER FLOW 2014, 2014, : 1323 - 1330
  • [29] Objective and subjective comparison of standard 2-D and fully 3-D reconstructed data on a PET/CT system
    Strobel, Klaus
    Rudy, Matthias
    Treyer, Valerie
    Veit-Haibach, Patrick
    Burger, Cyrill
    Hany, Thomas F.
    NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (07) : 555 - 559
  • [30] Trans-styloid and intrafocal pinning for extra-articular extension fractures of the distal radius: prospective randomized postoperative comparison with simple intra-focal pinning
    Gravier, R.
    Flecher, X.
    Parratte, S.
    Rapaie, R.
    Argenson, J. -N.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2006, 92 (07): : 657 - 662