A comparison of 3-D CT and 2-D plain radiograph measurements of the wrist in extra-articular malunited fractures of the distal radius

被引:0
|
作者
Smees, Camiel J. [1 ,2 ,4 ]
van Es, Eline M. [3 ]
Tuijthof, Gabrielle J. M. [2 ]
Colaris, Joost W. [3 ]
de Graaff, Feike [1 ]
Vochteloo, Anne J. H. [1 ]
机构
[1] Ctr Orthopaed Surg & Sports Med, OCON, Hengelo, Netherlands
[2] Univ Twente, Biomed Device Design & Prod Technol, Enschede, Netherlands
[3] Erasmus MC, Dept Orthopaed & Sports Med, Rotterdam, Netherlands
[4] Ctr Orthopaed Surg & Sports Med, OCON, Geerdinksweg 141, NL-7555DL Hengelo, Netherlands
关键词
Radial inclination; volar tilt; palmar tilt; ulnar length; axial rotation; diagnostics; radius malunion; CORRECTIVE OSTEOTOMY; COORDINATE SYSTEMS; COLLES FRACTURE; CARPAL BONES; MOTION;
D O I
10.1177/17531934231213790
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Two-dimensional (2-D) plain radiographs may be insufficient for the evaluation of distal radial malunion, as it is a three-dimensional (3-D) deformity. This study introduced a 3-D measuring method that outputs radial inclination, ulnar variance, palmar tilt and axial rotation. To this end, a standardized and clearly defined coordinate system was constructed that allowed 3-D measurements closely resembling the conventional 2-D method in 35 patients. Mean differences between 3-D and 2-D measurements in affected wrists were 1.8 degrees for radial inclination, 0.8 mm for ulnar variance and 3.7 degrees for palmar tilt. In addition, inter- and intra-observer reproducibility of all 3-D and 2-D measurements were good or excellent (intraclass correlation coefficient >0.75), with 3-D reproducibility always better than 2-D. Axial rotation was present in all patients with a mean of 7.9 degrees (SD 6.9). Although the differences between 2-D and 3-D measurements were small, 3-D evaluation enables the assessment of axial rotation and brings us closer to a routine 3-D evaluation of malunion.
引用
收藏
页码:546 / 553
页数:8
相关论文
共 50 条
  • [1] Comparison of extra-articular radiographic parameters of distal radius fractures on plain radiographs and CT scans
    Kramer, Simon B.
    Selles, Caroline A.
    Bakker, Daniel
    Schep, Niels W. L.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2022, 47 (02) : 142 - 149
  • [2] Z-Corrective Osteotomy in Malunited Extra-Articular Fractures of Distal Radius
    Bhatia, Nishant
    Gupta, Ajay
    Dabas, Vineet
    Kataria, Ankit
    Goel, Akash
    Yadav, Akash
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (06): : 585.e1 - 585.e10
  • [3] A less invasive distal osteotomy of the radius for malunited dorsally displaced extra-articular fractures
    Fok, M. W. M.
    Fernandez, D. L.
    Rivera, Y. L. Hernandez
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2015, 40 (08) : 812 - 818
  • [4] Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate
    Tarallo L.
    Mugnai R.
    Adani R.
    Catani F.
    Journal of Orthopaedics and Traumatology, 2014, 15 (4) : 285 - 290
  • [5] Positioning Evaluation of Corrective Osteotomy for the Malunited Radius: 3-D CT Versus 2-D Radiographs
    Vroemen, Joy C.
    Dobbe, Johannes G. G.
    Strackee, Simon D.
    Streekstra, Geert J.
    ORTHOPEDICS, 2013, 36 (02) : E193 - E199
  • [6] Corrective osteotomy for malunited extra-articular fractures of the distal radius: A follow-up study of 33 patients
    Krukhaug, Yngvar
    Hove, Leiv M.
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2007, 41 (06): : 303 - 309
  • [7] Comparison of Clinical Outcomes in Distal Radius Extra-articular Fractures with or without Ulnar Styloid Fracture
    Safari, Mir Bahram
    Tabrizi, Ali
    Kiasi, Naghi Ahangar
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2019, 7 (02): : 225 - 229
  • [8] Malunion of the distal radius: 3D planning and performance of intra-and extra-articular corrective osteotomy
    Laber, Raffael
    Schweizer, Andreas
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2023, 35 (05): : 258 - 269
  • [9] Comparison of five percutaneous pinning methods for unstable extra-articular distal radius fractures: A mechanical study using sawbones
    Muratli, S. Kivanc
    Uzun, Bora
    Celik, Salih
    JOINT DISEASES AND RELATED SURGERY, 2021, 32 (01): : 51 - 58
  • [10] Biomechanical Analysis of Volar and Dorsal Double Locking Plates for Fixation in Comminuted Extra-articular Distal Radius Fractures: A 3D Finite Element Study
    Lin, Yu-Hao
    Lin, Chun-Li
    Kuo, Hsien-Nan
    Sun, Ming-Tsung
    Chen, Alvin Chao-Yu