Mid-infrared dissolved CO2 measurement system using the ultra-compact multipass cell

被引:2
|
作者
Chen, Hongda [1 ]
Chen, Chen [1 ]
Dong, Weihao [1 ]
Li, Yongyang [1 ]
Zhang, Mengru [1 ]
机构
[1] Jilin Univ, Coll Instrumentat & Elect Engn, Minist Educ China, Key Lab Geophys Explorat Equipment, Changchun 130026, Peoples R China
基金
中国国家自然科学基金;
关键词
1f+3f WMS; fast response time; limit of detection; multipass cell; multiplexing multiple spectral lines; SPECTROSCOPY;
D O I
10.1002/mop.33450
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To measure natural gas hydrate, a mid-infrared dissolved CO2 measurement system is designed using the tunable diode laser spectroscopy with ultra-compact multipass cell. The QCL laser of 4319 nm has a scanning range from 2315.05 to 2315.40 cm(-1), which contains (CO2)-C-12 and (CO2)-C-13 for isotope measurement and wide range of concentration detection. The optimized 3f + 1f wavelength modulation method reduces the limit of detection to 7.1 ppbv. An ultra-compact multi-pass cell with effective optical path length of 6.3 m and small volume of 15 ml is designed to achieve the system response time of 40 s. The dissolved CO2 sensing system has been used in deep sea natural gas hydrate detection.
引用
收藏
页码:1319 / 1323
页数:5
相关论文
共 50 条
  • [31] Improving measurement accuracy of CH4 and CO2 sensing system using passive locking achromatic multipass absorption cell
    Wang, Peng
    Chen, Chen
    Wang, Yanzhang
    Cheng, Defu
    Piao, Heng
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 387
  • [32] Compact Mid-Infrared Spectrometer Using Continuously Variable Infrared Filter and Microbolometer Array for Simple and Fast Measurement of Molecular Mid-IR Spectra
    Jeon, Taeyoon
    Nateghi, Amirhossein
    Choi, Changsoon
    Jewell, Jack
    Scherer, Axel
    ADVANCED OPTICAL MATERIALS, 2024, 12 (12):
  • [33] In-Vivo Noninvasive Measurement of Human Blood Glucose Levels by Mid-Infrared Spectrograph with External CO2 Laser Source
    Zhang Qian-qian
    Fan Yu-ling
    He Xiu-quan
    Sun Yu-ming
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (01) : 85 - 88
  • [34] Portable Mid-Infrared Sensor System for Monitoring CO2 and CH4 at High Pressure in Geosequestration Scenarios
    Schaedle, Thomas
    Pejcic, Bobby
    Myers, Matthew
    Mizaikoff, Boris
    ACS SENSORS, 2016, 1 (04): : 413 - 419
  • [35] Development and field deployment of a mid-infrared CO and CO2 dual-gas sensor system for early fire detection and location
    Li, Yafei
    Yu, Ling
    Zheng, Chuantao
    Ma, Zhuo
    Yang, Shuo
    Song, Fang
    Zheng, Kaiyuan
    Ye, Weilin
    Zhang, Yu
    Wang, Yiding
    Tittel, Frank K.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 270
  • [36] CO2 monitoring and detection using an integrating sphere as a multipass absorption cell
    Hawe, E.
    Chambers, P.
    Fitzpatrick, C.
    Lewis, E.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (10) : 3187 - 3194
  • [37] A comparison of tissue effects produced by thulium fiber, CO2, and mid-infrared diode laser
    Lemberg, Vladimir
    Rozhetskin, Dmitry
    Jadczak, Chris
    LASERS IN SURGERY AND MEDICINE, 2008, : 58 - 58
  • [38] Fabrication of ultra-compact long-period fiber grating through differentially scanned CO2 laser
    Perez, Eric
    Chan, Hon M.
    Tomov, Ivan
    Lee, Henry P.
    PASSIVE COMPONENTS AND FIBER-BASED DEVICES III, PTS 1 AND 2, 2006, 6351
  • [39] Instantaneous Frequency Measurement System Using Four-Wave Mixing in an Ultra-Compact Long Silicon Waveguide
    Pagani, Mattia
    Morrison, Blair
    Zhang, Yanbing
    Casas-Bedoya, Alvaro
    Aalto, Timo
    Harjanne, Mikko
    Kapulainen, Markku
    Eggleton, Benjamin J.
    Marpaung, David
    ECOC 2015 41ST EUROPEAN CONFERENCE ON OPTICAL COMMUNICATION, 2015,
  • [40] Real-time measurement of CO2 isotopologue ratios in exhaled breath by a hollow waveguide based mid-infrared gas sensor
    Zhou, Tao
    Wu, Tao
    Wu, Qiang
    Ye, Chenwen
    Hu, Rongjing
    Chen, Weidong
    He, Xingdao
    OPTICS EXPRESS, 2020, 28 (08): : 10970 - 10980