Mid-infrared dissolved CO2 measurement system using the ultra-compact multipass cell

被引:2
|
作者
Chen, Hongda [1 ]
Chen, Chen [1 ]
Dong, Weihao [1 ]
Li, Yongyang [1 ]
Zhang, Mengru [1 ]
机构
[1] Jilin Univ, Coll Instrumentat & Elect Engn, Minist Educ China, Key Lab Geophys Explorat Equipment, Changchun 130026, Peoples R China
基金
中国国家自然科学基金;
关键词
1f+3f WMS; fast response time; limit of detection; multipass cell; multiplexing multiple spectral lines; SPECTROSCOPY;
D O I
10.1002/mop.33450
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To measure natural gas hydrate, a mid-infrared dissolved CO2 measurement system is designed using the tunable diode laser spectroscopy with ultra-compact multipass cell. The QCL laser of 4319 nm has a scanning range from 2315.05 to 2315.40 cm(-1), which contains (CO2)-C-12 and (CO2)-C-13 for isotope measurement and wide range of concentration detection. The optimized 3f + 1f wavelength modulation method reduces the limit of detection to 7.1 ppbv. An ultra-compact multi-pass cell with effective optical path length of 6.3 m and small volume of 15 ml is designed to achieve the system response time of 40 s. The dissolved CO2 sensing system has been used in deep sea natural gas hydrate detection.
引用
收藏
页码:1319 / 1323
页数:5
相关论文
共 50 条
  • [21] Compact mid-infrared laser sensor for temperature and CO concentration measurement using heterodyne phase-sensitive dispersion spectroscopy
    Wang, Weitian
    Fu, Pengfei
    Song, Zihao
    Wang, Zhenhai
    Zhu, Ning
    Ma, Liuhao
    Chao, Xing
    MEASUREMENT, 2025, 244
  • [22] Design of Mid-infrared Negative Filter Against CO2 Radiation (Invited)
    Fu Xiuhua
    Zhang Tianxiang
    Xiong Shifu
    Lin Zhaowen
    Wang Ben
    ACTA PHOTONICA SINICA, 2022, 51 (09)
  • [23] Phonon-Enhanced Mid-Infrared CO2 Gas Sensing Using Boron Nitride Nanoresonators
    Bareza, Nestor, Jr.
    Paulillo, Bruno
    Slipchenko, Tetiana M.
    Autore, Marta
    Dolado, Irene
    Liu, Song
    Edgar, James H.
    Velez, Saul
    Martin-Moreno, Luis
    Hillenbrand, Rainer
    Pruneri, Valerio
    ACS PHOTONICS, 2022, 9 (01) : 34 - 42
  • [24] Flow and heat transfer of supercritical CO2 in the honeycomb ultra-compact plate heat exchanger
    Pei, Binbin
    Chen, Zhentao
    Li, Fangbo
    Bai, Bofeng
    JOURNAL OF SUPERCRITICAL FLUIDS, 2019, 148 : 1 - 8
  • [25] A Mid-Infrared Quantum Cascade Laser Ultra-Sensitive Trace Formaldehyde Detection System Based on Improved Dual-Incidence Multipass Gas Cell
    Wu, Tao
    Hu, Renzhi
    Xie, Pinhua
    Zhang, Lijie
    Hu, Changjin
    Liu, Xiaoyan
    Wang, Jiawei
    Zhong, Liujun
    Tong, Jinzhao
    Liu, Wenqing
    SENSORS, 2023, 23 (12)
  • [26] Development and Measurements of a Mid-Infrared Multi-Gas Sensor System for CO, CO2 and CH4 Detection
    Dong, Ming
    Zheng, Chuantao
    Miao, Shuzhuo
    Zhang, Yu
    Du, Qiaoling
    Wang, Yiding
    Tittel, Frank K.
    SENSORS, 2017, 17 (10)
  • [27] Volume detection based on porous silicon waveguide for CO2 mid-infrared spectroscopy
    Meziani, Sofiane
    Jaafar, Abdallah
    Hammouti, Abdelali
    Bodiou, Loic
    Lorrain, Nathalie
    Pirasteh, Parastesh
    Courson, Remi
    Lemaitre, Jonathan
    Nazabal, Virginie
    Guendouz, Mohammed
    Charrier, Joel
    OPTICS EXPRESS, 2024, 32 (08): : 13628 - 13639
  • [28] Design and performance evaluation of a mobile CO2 detector based on mid-infrared IBBCEAS
    Chen, Jianbo
    Wang, Jianing
    Chang, Shuai
    Li, Pengbo
    Lin, Guanyu
    Tong, Shoufeng
    Li, Zhen
    Luo, Yinwei
    MEASUREMENT, 2025, 247
  • [29] CO and CO2 dual-gas detection based on mid-infrared wideband absorption spectroscopy
    董明
    钟国强
    苗澍茁
    郑传涛
    王一丁
    OptoelectronicsLetters, 2018, 14 (02) : 119 - 123
  • [30] CO and CO2 dual-gas detection based on mid-infrared wideband absorption spectroscopy
    Dong M.
    Zhong G.-Q.
    Miao S.-Z.
    Zheng C.-T.
    Wang Y.-D.
    Zheng, Chuan-tao (zhengchuantao@jlu.edu.cn), 2018, Springer Verlag (14): : 119 - 123