Needle Aligned Ultrasound Image-Guided Access Through Dual-Segment Array

被引:1
|
作者
Rahaman, Ashiqur [1 ,2 ]
Tang, Yichuan [1 ]
Gao, Shang [1 ]
Ma, Xihan [1 ]
Sorokin, Igor [3 ]
Zhang, Haichong K. [1 ,2 ,4 ]
机构
[1] Worcester Polytech Inst, Dept Robot Engn, Worcester, MA 01609 USA
[2] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01609 USA
[3] Univ Massachusetts, Med Sch, Dept Urol, Worcester, MA USA
[4] Worcester Polytech Inst, Dept Comp Sci, Worcester, MA 01609 USA
基金
美国国家卫生研究院;
关键词
Needles; Acoustic beams; Probes; Kidney; Imaging; Image segmentation; Visualization; Needle-image alignment; Percutaneous intervention; Ultrasound-guided intervention; Dual-segment array; PERCUTANEOUS NEPHROLITHOTOMY; VISUALIZATION; GUIDANCE; FREEHAND; BIOPSY; SYSTEM;
D O I
10.1109/TBME.2023.3260735
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultrasound (US) guided access for percutaneous nephrolithotomy (PCNL) is gaining popularity in the urology community as it reduces radiation risk. The most popular technique involves manual image-needle alignment. A misaligned needle however needs to be retracted and reinserted, resulting in a lengthened operation time and complications such as bleeding. These limitations can be mitigated through the co-registration between the US array and needle. The through-hole array concept provides the primary solution, including a hole at the center of the array. Because of the central opening, the image-needle alignment is achieved inherently. Previous literature has described applications that are limited to superficial and intravascular procedures, suggesting that developing a through-hole array for deeper target applications would be a new breakthrough. Objective. Here, we present a dual-segment array with a central opening. As the prototype development, two segments of 32-element arrays are combined with an open space of 10 mm in length in between them. Method. We conducted phantom and ex-vivo studies considering the target depth of the 80-100 mm range. The image quality and needle visibility are evaluated by comparing the signal-to-noise ratio (SNR), full width at half maximum (FWHM), and contrast-to-noise ratio (CNR) results measured with a no-hole linear array under equivalent conditions. An ex-vivo study is performed using porcine kidneys with ceramic balls embedded to evaluate the needle access accuracy. Results and conclusion.The mean needle access error of 20 trials is found to be 2.94$\pm$1.09 mm, suggesting its potential impact on realizing a simple and intuitive deep US image-guided access.
引用
收藏
页码:2645 / 2654
页数:10
相关论文
共 50 条
  • [31] Image-guided core needle biopsy for musculoskeletal lesions
    Toki, Shunichi
    Sone, Miyuki
    Yoshida, Akihiko
    Nishisho, Toshihiko
    Gokita, Tabu
    Kobayashi, Eisuke
    Nakatani, Fumihiko
    Chuman, Hirokazu
    Sugawara, Shunsuke
    Arai, Yasuaki
    Kawai, Akira
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2022, 27 (02) : 448 - 455
  • [32] Angular needle tracker and stabilizer for image-guided interventions
    Zhao, Zhuo
    Li, Rui
    Xu, Lingwen J.
    Enzmann, Dieter R.
    Wood, Bradford J.
    Tse, Zion Tsz Ho
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2022, 31 (03) : 410 - 417
  • [33] On Pathologic Diagnoses by Image-guided Core Needle Biopsies
    Szabo, Sara
    JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2014, 36 (05) : 329 - 331
  • [34] High intensity focused ultrasound (HIFU) array system for image-guided ablative therapy (IGAT)
    Kaczkowski, PJ
    Keilman, GW
    Cunitz, BW
    Martin, RW
    Vaezy, S
    Crum, LA
    THERMAL TREATMENT OF TISSUE: ENERGY DELIVERY AND ASSESSMENT II, 2003, 4954 : 209 - 219
  • [35] A three-dimensional micro-ultrasound image-guided and robotically assisted needle positioning system
    Waspe, A
    Cakiroglu, H
    Lacefield, J
    Fenster, A
    MEDICAL PHYSICS, 2005, 32 (07) : 2421 - 2421
  • [36] Image-guided Access to the Spinal Subarachnoid Space in Children
    Islam, Shah
    Parra-Farinas, Carmen
    Muthusami, Prakash
    Shroff, Manohar
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2025, 35 (01) : 155 - 165
  • [37] Contrast-Enhanced Ultrasound for Image-Guided Procedures
    Russell, Gentry
    Strnad, Benjamin S.
    Ludwig, Daniel R.
    Middleton, William D.
    Itani, Malak
    Khot, Rachita
    Mellnick, Vincent
    Malone, Christopher
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 26 (03)
  • [38] Magnetic resonance image-guided focused ultrasound surgery
    Jolesz, FA
    Hynynen, K
    CANCER JOURNAL, 2002, 8 : S100 - S112
  • [39] A Google Glass navigation system for ultrasound and fluorescence dual-mode image-guided surgery
    Zhang, Zeshu
    Pei, Jing
    Wang, Dong
    Hu, Chuanzhen
    Ye, Jian
    Gan, Qi
    Liu, Peng
    Yue, Jian
    Wang, Benzhong
    Shao, Pengfei
    Povoski, Stephen P.
    Martin, Edward W., Jr.
    Yilmaz, Alper
    Tweedle, Michael F.
    Xu, Ronald X.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XIV, 2016, 9698
  • [40] Auditory feedback to support image-guided medical needle placement
    Black, David
    Hettig, Julian
    Luz, Maria
    Hansen, Christian
    Kikinis, Ron
    Hahn, Horst
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2017, 12 (09) : 1655 - 1663